Laserfiche WebLink
z7 u <br /> N U ( <br /> rc z w <br /> Q rc b w Z <br /> Z Q > Z 0 v <br /> U O O w Z O <br /> Z <br /> O w r <br /> u u ? 2 2 <br /> Z V) 0 0 <br /> w w <br /> O � 0 V <br /> TRENCH#1 SAWDUST&SAND MIX <br /> J it n :� � � <br /> 042" SEEPAGE PIT LYSIMETER LOCATION(TOTAL OF 3, J 01 A" SCH40 PVC <br /> TO BE INSTALLED BY I UNDER DISCHARGE PIPE (TYP.) Z O <br /> SEPERATE CONTRACT) Q N o <br /> ^ ^ TRENCH #2 - SAWDUST 8 SAND MIX N o <br /> z <br /> m <br /> 0'( 10.. t1��G�' 03"CARBON-FILTER AIR VENT 0 O F 0 o n <br /> /E9nq'Lii,1, ^oP Q.PQ� (TYP. OF 2 PER ROW) o ¢ c' ao <br /> 2)-, <br /> ' GAO W z 0 ? z <br /> TRENCH#3- SAWDUST 8 SAND MIX Z Q 01 O O <br /> VPJIlw <br /> "Y" OR TEE 01.5" SCH40 PVC <br /> CONNECTION 02"SCH40 PVC MONITORING PORT MANIFOLD PIPE(TYP.) <br /> / (5 PORTS TOTAL) <br /> TRENCH #4- SAWDUST&SAND MIX <br /> 1 _., — ._ __ ._ - - - - - - -.- - <br /> 1 0 _. .-. ... <br /> / \ ADJUSTMENT FLOW VALVE <br /> NP.) <br /> T <br /> — �CLEANOUT IRRIGATION BOX(TVP.) 110 <br /> )'-TRENCH#5 SAND MIX ONLY y <br /> ..I Ui 'r <br /> 042" SEEPAGE PIT - PLAN VIEW —19INFILTRATORS FOR ATOTAL OF76'-0"OF EFFECTIVE AREA(TYPICAL) la <br /> 1/2... = 1'-0" z Z <br /> y 096 z ^ <br /> li b <br /> 1ti to � toSEPTIC FIELD LAYOUT - PLAN VIEW SAN.IOAoulNoan"Y r '@IVIROIMIENTALHMTHOSPARIABR 9 — <br /> REMOVABLE INSPECTION CAP 1/811-1 -O WEBERE/TOWONCA /640toM <br /> 10'(NP.) NON-WOVEN �.�..•• it <br /> C <br /> / FILTER FABRIC PROPQBALAPPROVED BIBJECT TO: .7 <br /> OBTNN SANITATION PE7tl1IN► r�. <br /> - -- — — �j <br /> OB. MIEIJRUMP PERM y� <br /> ❑ CONDfTI0148 NOTED BELOW ' <br /> _—.—.. ._._ F. _ _ _ <br /> FROM INFILTRATOR <br /> 14 <br /> _ V <br /> \ <br /> I `--04" SDR35 Y"OR TEE <br /> approval extends only to th t wfiidt is shown and d#sMDed <br /> I I I I TIGHT LINE CONNECTION ereon and deem' ^^ �r aoorove a omission or <br /> (5)-02" SCH40 PVC <br /> MONITORING PORT <br /> 48'EFFECTIVE LENGTH(TYP.) p2 <br /> ORENCO CF3-3" ORENCO CF3-3" 4 <br /> I I I CARBON-FILTER AIR VENT CARBON-FILTER AIR VENT <br /> I I I CLEANOUT (OBSERVATION PORT) (OBSERVATION PORT) <br /> I I PVC FEMALE ADAPTER WITH THREADED CAP TO 24"TRENCH <br /> FINISHED GRADE OR PLACE WITHIN AN IRRIGATION BOX ADJUSTMENT 18" <br /> FLOW VALVE <br /> I I QUICK4 EQUALIZER 24 <br /> VO <br /> OLA LATERALS W/PRES�Z 0 <br /> ai <br /> - _ - —_ _ CHAMBER II — eg <br /> — <br /> 04" SDR35 TIGHT LINE 8' 111 IJ 11 VIII I END CAP V I I I �I -I IFII EIP I iI (iVPJ p g• I I— I I p[ <br /> _ III <br /> I I I I - JA _ <br /> DEPTH (NP) I I I I — — — — _ 7 7 5" 11" BACKFILL _I 1 111 <br /> _ � � 1=111ll111 <br /> TO SES <br /> II —II II 11 II 11 —I w <br /> I —fir �Tr h, , <br /> 11_111_1 II_III_III II I_i o o a <br /> m 8" 3/4"-2" CRUSHED 8 <br /> SCARIFY PIT SIDES I I I I--I I I III I �- l.. __ L WASHED GRAVEL O C <br /> J —III I_I III—I 111 III=�! > <br /> III—i I I L I I I III—III—I I f III L1 I I I=11 I I � <br /> I_I i 1=11 f=1 l I—F 11.I I 1=1 11=1 I 111-11 = I; <br /> I 1 I 1=1 I f-1 I I I I_=1 I I I I 1 I 1 I I I 11_ ,111-111 <br /> — -- N M ? vl b n W P <br /> I 1 I 1 I_I I I=11—fi JJ 11 I 1 I f I 11-11 I-I11-111 11 I=�( 11 TRENCH#1 THRU#4: <br /> w — J - - - -- -I-- — � --- — �'�7-- 111=111-111 111=III 111—II1-111—III i <br /> TRENCH#1 THRU#4: �I—III 17% SAWDUST BY VOLUME <br /> 1 -11 -III -I 11 III III-III 1 1 1 17% SAWDUST BY VOLUME <br /> =1 I=) I=111=11 =111=1 I-1 I-III- ! ' TRENCH W=Ew=1 2'6" 83% COARSE SAND <br /> —IF <br /> COARSE <br /> Y VOLUME <br /> o , I I, _ I I ISI 1111111 11111— :71111 iI I 111 i1 12" SAW-CUT = <br /> MIXED THOROUGHLY SAND <br /> B VCONTRACTOR � i � BY VOLUME <br /> —1 MIXED THOROUGHLY <br /> HOLY BY <br /> L __ _ _ _ _ _ _J SLOTS WRAPPED <br /> -T-11 I -I I-1 I- IIII IN GEO-FABRIC <br /> 111=7-III 111-111=1 I I_I I I III i I I-: I I I=11 I I <br /> " All 042" 6" FROM 042' =111=1 i III III-� III-1 - =I 1 <br /> o (TYP.) BOTTOM — - — <br /> ro <br /> n <br /> 0 <br /> M <br /> ]OB NUMBER: <br /> _ NOTES: <br /> 1. PLEASE PROVIDE OUR OFFICE WITH A SAMPLE OF SAND OR SPEC E06122A <br /> a SHEET FOR APPROVAL. <br /> a 2. WOOD CELLULOSE MAY BE EITHER SAWDUST OR WOOD CHIPS SCALE: <br /> LESS 042" SEEPAGE PIT DETAIL OR OTHER <br /> WOOD PRODUCTS CONTAININGGLUEINFILTRATOR TRENCH DETAIL 1 "=30'-O" <br /> OR OTHER ADDITIVES ARE NOT ACCEPTABLE. ONLY VIRGIN WOOD <br /> PRODUCTS ARE ACCEPTABLE. DATE: <br /> 1'-0" NTS s/s/m <br /> V <br /> o DRAWN BY: <br /> RC <br /> i <br /> DESIGNED BY: <br /> iDW <br /> w <br /> E <br /> i)v wpanvmmcmmoidRYmmlN awiMa m cko�urail'0 sal�ipE w�AIEnRoleaoarl arwoMm. <br /> SHEET: G2 cocmlcx*ergao.ammaor+nxo�saoc..lec. L <br /> U <br /> Copyright V2007 Neil Anderson-All Rights Reserved-This document was prepared for use only by the client, only for the purposes stated and within a reasonable timeimmissuance. Non-commercial.educational.and soentificuse ofthisreport by regulatory agencies is regarded as a"fairuse"and not a violation ofcopyright. Regulatory agencies may make additional copies of this document for internal use. Copies may also be made available tolhe publicasrequired by law. The repent must acknowledge the cepynghland indicate that permission to reprint has been received. <br />