Laserfiche WebLink
_ 5 <br /> necessity for abandonment of the well or treatment of the <br /> water. <br /> Another consideration involves cross contamination of I <br /> aquifers by construction of the well as proposed. By <br /> screening the contaminated aquifer at the 165 foot depth <br /> along with the deeper uncontaminated aquifers, the City will I <br /> create an avenue for DBCP to migrate from the contaminated <br /> aquifer into the uncontaminated aquifers, thereby <br /> compromising the quality of the deeper waters. As a result, <br /> it is recommended that the City of Lodi review the proposed <br /> construction of Well No. 22 and seriously consider sealing ; <br /> -out the-water—from-the aquifer"at=this'16'5—foot depfh. <br /> Before initiating construction of Well No. 22 , submit a <br /> complete set of final construction plans to the Department <br /> for review and approval. <br /> S fi. 1� �i . ilda�✓a��'i�� <br /> 1 <br /> Robert W. Grimshaw, P.E. <br /> District Engineer <br /> Sanitary Engineering Branch <br /> JOS/RWG:hmg <br /> cc: San Joaquin Local Health Department <br /> Lodi#22 �- <br /> i <br /> i <br /> i <br />