Laserfiche WebLink
°U�"'" SAN. JOAQUIN Environmental Health Department <br /> i" COUNTY Linda Turkatte, RENS, Director <br /> ` P.' Greatness grows here. <br /> Kasey Foley,REHS,Assistant Director <br /> PROGRAM COORDINATORS <br /> Robert McClellon,REHS <br /> Jeff Carruesco, REHS,RDI <br /> Rodney Estrada,REHS <br /> Willy Ng,REHS <br /> C <br /> � � Muniappa Naidu,RENS <br /> 11/20/2017 j <br /> I.J Larson Pumps Inc. <br /> 509 Tully Rd <br /> Modesto, CA 95350. <br /> RE: Well Pump Inspection <br /> Well Location: 27488 S. Corral Hollow Rd Tracy Permit#: SR0075705 Inspection Date: 07/05/2017 <br /> The Environmental Health Department recently conducted a water well pump inspection at the above <br /> address and found the following issues at the time of the inspection. In order to protect the ground water <br /> supply and your water source from potential degradation, please take the associated corrective actions. <br /> ❑ Lack of or Inadequate Concrete Platform around Wellhead. <br /> (SJC Water Well Standards, Section 4.10.—Surface Seal) <br /> Corrective Action: Repair existing or install a new concrete platform around the wellhead. <br /> ❑ Lack of or Inadequate Sanitary Seal at Wellhead. <br /> (SJC Ord. Code,Title 9, Section 9-1115.5.—Well Regulations) <br /> Corrective Action: Install a sanitary seal between casing and well cover plate/seal all gaps and <br /> openings. <br /> ❑x Lack of or Inadequate Sampling Tap. <br /> (SJC Water well Standards, Section 4.13.—Sampling Tap) <br /> Corrective Action: Install a non-threaded sampling tap between the wellhead and the check valve <br /> or within three (3) feet of the well head. <br /> ❑ Lack of or Inadequate Backflow Prevention. <br /> (SJC Water Well Standards, Section 4.14.—Backflow Prevention) <br /> Corrective Action: Install an approved protective device to prevent backflow and/or back <br /> siphonage into a well. <br /> ❑ Sounding Tube or Air Vent not Sealed. <br /> (SJC Water Well Standards, Section 4.13.—Sounding Tube/Air Vent Pipe) <br /> Corrective Action: Sounding Tube or Fill Pipe-Install a watertight, threaded cap at the upper end <br /> of the pipe. Air Vent-extend pipe 12 inches above with end inverted in a <br /> downward direction and covered with 16-mesh screening. <br /> ❑ Excessive Vegetation or debris around Wellhead. <br /> (SJC Ord. Code, Section 9-1115.4.—Dangerous/Nuisance) <br /> Corrective Action: Remove and maintain debris and vegetation away from well area. <br /> ❑ Other: <br /> If you have any questions please call Paul Nso, Assistant Environmental Health, at 209-969-5628 <br /> CC: Kathy Martinez-274 Corral Hollow Rd Tracy, CA 95377. <br /> ney Estrada, REHS <br /> Program Coordinator <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />