� l I REFER TO SHEET 1 FOR CONTINUATION OF SPECIFICATIONS. <br /> DIVISION 8 DOORS, WINDOWS & GLASS <br /> UNDEVELOPED � EXG GRAVEL EXG MCC-2 o`Sl ® = EXG CONC � <br /> ELEG PANEL n 1 PAD 08000 GENERAL INFORMATION: <br /> o' A} REFER TO THE DOOR AND WINDOW SCHEDULES FOR ADDITIONAL v <br /> 9g_• g•99`G 1 _ REQUIREMENTS. CONFIRM WITH THE OWNER FOR THE HARDWARE BRAND, LOCI{ <br /> _ 1 SYSTEM, FINISH, AND STYLE OF ALL MANUFACTURED DOOR AND WINDOW p <br /> 1 i SYSTEMS. DOOR CONSTRUCTION IS TO COMPLY WITH SECTION 1008 OF THE 9 I n M <br /> EX DOMESTIC1 2013CBC. n <br /> 0 <br /> G i � � <br /> 0 <br /> y]Ej,j,, 0, EXG CONC B) DOORS AND WINDOWS BETWEEN CONDITIONED AND UNCONDITIONED SPACES <br /> O 'GG ST�p,E3 SHALL BE DESIGNED TO LIMIT AIR LEAKAGE INTO OR FROM THE BUILDING <br /> a,�C bl ENVELOPE. ALL EXTERIOR DOORS AND WINDOWS ARE TO BE AN EXTERIOR <br /> cnl BARRIER FOR A WEATHER TIGHT AND CLOSED BUILDING SYSTEM. <br /> C) SITE-CONSTRUCTED DOORS AND WINDOWS, EXTERIOR JOINT'S, AND <br /> ~EXG 6�ry� WB OPENINGS IN THE BUILDING ENVELOPE THAT ARE OBSERVABLE SOURCES OF AIR0 <br /> c51 EXG ELEC LEAKAGE SHALL BE CAULKED, GASKETED, WEATHER-STRIPPED OR OTHERWISE <br /> EXG CONC o SEALED. n, <br /> SLAB o a� pl PANEL. D) UNLESS NOTED; THE TOPS OF ALL ISOLATED WINDOWS ARE TO BE LOCATED w <br /> rh <br /> EXG GRAVEL EXG GRAVEL , EXG WELL � ) 7'-0" ABOVE FINISH FLOOR. <br /> zpp EXG ml EXG CENTRIFUGE 08650 STORE FRONT: p a � jY LTJ Q <br /> 9$ fpr 9$•4gr 6a'G pare Z PAD. � F" �1.0 <br /> ��; �_ r• gg. G I CONCRETE I A) ALUMINUM STORE FRONT WINDOW/DOOR SYSTEM IS TO HAVE BRONZE ANODIZE z \ �C <br /> �o ��• PAVEMENT FRAME SECTIONS THAT ARE 2" x 4 1/2" FOR DOUBLE PANE, 1 3/4" x 4 1/2" <br /> Z¢ 0FOR SINGLE PANE (CONFIRM SECTIONS WITH SUPPLIER) . ALL GLAZING & p I� N <br /> �pCs Icl C) I FRAMING SECTIONS ARE TO BE DESIGNED FOR THE PROJECT'S NORMAL TO WALT, U C <br /> >-I <br /> WIND LOADING. <br /> 08800 GLASS & GLAZING: <br /> w 0 0 1) 0w W0 <br /> A) REFER TO CHAPTER 24 OF THE 2013CBC FOR THE PROJECT'S GLASS & \ l <br /> p 1 GLAZING REQUIREMENTS. <br /> 10 <br /> 9 DIVISION 9 FINTSHES s , .� 1r <br /> .� <br /> � � � 09000 GENERAL INFORMATION:0 <br /> 0 � <br /> 00 0 <br /> l A) WALL AND CEILING MATERIALS SMALL COMPLY WITH CHAPTER 8 OF THE0 <br /> a <br /> (Q z Z 2013CBC AND ARE TO NOT EXCEED THE FLAME SPREAD CLASSIFICATIONS IN0 <br /> 0 s <br /> O O 1 O EXG MAIN EXISTING TABLE 803.9 OF THE 2013CBC. - <br /> rr,Z, 0 0ELECTRICALD 0 B) RESTROOM FLOORING IS TO BE APPROVED SMOOTH, HARD, NONABSORBENT r4 <br /> 0 0 PANEL. FERMENTING SURFACE {CERAMIC TILE, NON-ABSORBENT PORTLAND CEMENT/CONCRETE, 0 <br /> tz] W U] I TERRAZZO MARBLE...) . FLOORING IS TO EXTEND UPWARD ONTO THE WALLS AT W G1� ER <br /> (EXG CELLAR LEAST 6 INCHES AND BE SEALED AGAINST WALL FOR WASHING & CLEANING OF 0NK U0 I ® 0 THE ROOM (NO GAPS AT ANY SEAMS) . WALLS WITHIN WATER CLOSET xUNDEVELOPED 98 +G 225 COMPARTMENTS TO A HEIGHT OF NOT LESS THAN 4 FEET AND WITHIN 2 FEET $ moo` � pO <br /> AREA 9 'G 46'G 9x•520 z co h a <br /> �� ��s pZr I OF THE FRONT AND SIDES OF URINALS TO A HEIGHT OF NOT LESS THAN 4 H <br /> W BM 2 EXG rn CONCRETE WORK SLAB pp pg r0 WR 704.09+e 1 FEET, SHALL BE FINISHED WITH APPROVED SMOOTH, HARD, NONABSORBENT q r r U U <br /> EXG 9g SURFACE (CERAMIC TILE, NON-ABSORBENT PORTLAND CEMENT/CONCRETE, w z o <br /> c1 0' g <br /> \1. <br /> PDMH >' TERRAZZO, MARBLE. . . ) (GYPSUM WALLBOARD USED FOR BACKING IS TO BEG .9 pj3Q C�, WATER-RESISTANT, REFER TO SECTIONS 1210 AND 2509 OF THE 2013CBC)EXG GRAVEL \v' G 9 �i , g .{U A EXG I ACCESSORIES SUCH AS GRAB BARS TOWEL BARS PAPER DISPENSERS AND SOAP EXG CAPPED g`� Q�, � � r ' a ��z0��1 iK <br /> ,r �• G �C a CONCRETE 1 DISHES, PROVIDED ON OR WITHIN WALLS, SHALL BE INSTALLED AND SEALED � <br /> 9$ 92�G B PD EXG 8"PD I _C5 99.1'1 PAVEMENT TO PROTECT STRUCTURAL, ELEMENTS FROM MOISTURE. Q <br /> Q <br /> 98 C)�, W WQ I — — — — — — — C) CONFIRM WITH THE OWNER THE FINISH PAINTING, FLOORING AND TRIM w <br /> MOLDING REQUIREMENTS FOR THE PROJECT. <br /> m <br /> EXG GRAVEL Wk 04 1`� <br /> '7, <br /> Ew, .\ 1 0 <br /> O W W � I 09250 GYPSUM WALLBOARD. ALL GYPSUM WALLBOARD IS TO BE 5/8" THICK <br /> W 0) 1 9 EXG SEPTIC 1 AND IS TO CONFORM TO CHAPTER 25 OF THE 2013CBC FOR INSTALLATION <br /> +G 9$ O q �'�`� 99' �o� TANK SYSTEM. UNLESS NOTED. <br /> 9a 02 4$rG =�• I i� a �, � z <br /> 9 W� T ngS� I 09550 SUSPENDED CEILING: THE SUSPENDED ACOUSTICAL CEILING SYSTEM IS Q <br /> l 1 d6'p G o EXG TO CONFORM TO SEC 808 OF THE 2013CBC FOR DESIGN AND INSTALLATION. 14 <br /> THE SUSPENDED CEILING SYSTEM IS TO BE THE 1200 SYSTEM BY CHICAGO <br /> Fi <br /> Cb 0 O O EXG SITE EXISTING METALZIC CORPORATION (ICBG REPORT NO. 1905) OR EQUAL. THE MAIN <br /> rr9-9. <br /> EXG CO NC l RUNNERS #240, ARE TO RUN .PERPENDICULAR TO THE ROOF PURLINS/JOISTS <br /> PAVEMENT CELLAR #1 <br /> 2+'SLFfh �+� 9g 00 rC PAVEMENT 1 ' <br /> �' � AND ARE TO BE SPACED AT 4'-0 Q.C. USE MINIMUM NO. 12-GAGE, <br /> 9a —EXG LEACH g� 0 gE ABAND�D xN PLACE) EXG T 1 a <br /> GALVANIZED, SOFT-ANNEALED, MILD STEEL WIRE AT 4'-0 SPACING ALONG THE u <br /> IELD AREA �• � MAIN RUNNERS FOR TIES TO THE ROOF JOIST SYSTEM. PROVIDE ADDITIONAL H <br /> s6,� l TIES AT 81-0 SPACING ALONG THE MAIN RUNNERS, INSTALLED APPROXIMATELY <br /> ExG �? EXG GRAVEL 1 �A �jl 45 DEGREES IN ALL FOUR DIRECTIONS TO THE UPPER ROOF PURLINS/JOISTS, p Q <br /> O �� EXG GRAVEL 1 EXISTING � ) FOR THE HORIZONTAL STABILITY OF THE CEILING SYSTEM. INSTALL O <br /> ( - — — — — — —. —— — — — - DC � ® INTERMEDIATE CROSS MEMBERS (41210 AND #1226) TO FORM 2'-0 X 4'-0 � ✓-' <br /> Oo O O 98, �1 'G W .2 OFFICE 8s,4FFICE W 1 CONNECT TOCEILING TEAHSWAiLAS NSTUDD(SEPARATION OFETHEACEI NGEAT#ALLgWALLSIS TOIS z <br /> ��// EXG T EXG, SUGAR Sg•G +C, 1 EXG 98'6>, Q F'F i — REQUIRED) WITH (1) NO. 6 METAL SCREW TO STEEL STUDS {NO. 8 X 1 1/2" E <br /> WING Q TEST STAND y$' og.3� i PP �'p WOOD SCREW AT WOOD STUDS) , AND TO EACH MAIN RUNNER WITH (1) 1/8" � � 0 Q <br /> EXISTING 19'-3" S STEEL RIVET. NOTE, ALL PANELS, LIGHT FIXTURES, AND HVAC VENTS ARE <br /> GATE TO BE REMOVED. 98 8 2 TO BE CLIPPED TO THE RUNNERS AND CROSS MEMBERS FOR WIND AND SEISMIC � <br /> g2yc �'• spa STMILITY. VERIFY STYLE OF ACOUSTICAL LAY-IN PANELS WITH OWNER. H O <br /> EXG GRAVEL EXG CONCRETE B 10'G EXG GRAVEL I9I Il' �� EXG SITE DIVISION 13 PRE-ENGINEERED MANUFACTURED ITEMS u Q <br /> TRUCK SLAB. 9g PAVEMENT Q <br /> ,.��--��-- --------r�r.•-----�-- .r Jnr r�+r�rr rr r.rr 1EYsB <br /> a <br /> SOUTH 0Fc/G SOUTH SOUTH 13122 GENERAL INFORMATION TO THE STEEL BUILDING MANUFACTURER <br /> 766.58' —rr r—e0r.r00' r (SBM) :6gIC . <br /> 9� 66rC <br /> A) THE SM'S CCULATONS AND <br /> RWNGS <br /> RE TO COMlY <br /> - EXG 8"NWS PROJECT"SBDRAWINGS ANDIMAINTAINDTHEIGRID ASYSTEM ASPNOTED. <br /> THE u <br /> 80FOR B) GOVERNING BUILDING CODE - 2C13CBC. NOTE THE STEEL BUILDING Ca a � <br /> 9_7 ' _ SUPPLIER MUST FURNISH ADEQUATE STRUCTURAL CALCULATIONS AND DRAWINGS <br /> - - - - - - - - - - - - - - - - - - - - - _ _ _ - - _ - FURRY ROAD _ T _ _ - _ - _ _ _ FOR THE DESIGN REVIEW AND PROJECT CONSTRUCTION AND ALSO FOR <br /> 44 <br /> COMPLYING WITH THE SAN JOAQUIN COUNTY'S B.T.D. O W <br /> C) ALL STRUCTURAL STEEL IS TO BE IN COMPLIANCE WITH THE "CODE OF p H <br /> `� <br /> STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES" OF THE AISC z <br /> T O P O GRA P I C SURVEY- WITHMANUAL, 13TH EDITION. ALL WELDING T5 TO BE PERFORMED IN COMPLIANCE <br /> WITH CHAPTER 17 OF THE 2013CBC FOR SPECIAL INSPECTION OR BY AN � U H <br /> APPROVED ICBG FABRICATION SHOP, FOR WELDER QUALIFICATION w 2) U) Q <br /> N SCAJ,E: 1rr _ 34.Or - REQUIREMENTS, WELDING PROCEDURE, AND WELDING ELECTRODES, REFER TO W Q Q 0 <br /> y ► <br /> APN: BK 061 PG 16 PARCEL 26 SECTION 2204.1 OF THE 2013CBC. O <br /> D) ALL CONNECTIONS REQUIRING THE UTILIZATION OF HIGH STRENGTH W <br /> 73.35 ACRES BOLTS, TYPES A325 & A490, ARE TO COMPLY WITH CHAPTER 17 OF THE H r� O r-I <br /> 2013CBC FOR SPECIAL INSPECTION DURING ALL BOLT INSTALLATIONS AND <br /> 124 (D <br /> TIGHTENING OPERATIONS UNLESS NOTED. ALL HIGH STRENGTH BOLTS ARE TO w <br /> BE INSTALLED AND TIGHTENED IN COMPLIANCE WITH AISC MANUAL, 13TH E <br /> EDITION, ITEM J3, FOR MINIMUM PRE-TENSIONING CONNECTIONS. rj <br /> E) REFER TO 01000C FOR THE PROJECT'S APPLIED LOADING CRITERIA. z <br /> LEGEND F} ALL STRUCTURAL FRAMING (FRAMES, GTRTSr PURLINS, ETC.) TS TO HAVE , <br /> A COATING OF SHOP PRIMER PAINT THAT IS RUST INHIBITIVE. <br /> G) METAL DECKING: ALL EXTERIOR STEEL PANELING BY THE SBM IS TO m <br /> NOTE; C TOP OF CONCRETE. ,A DESIGNATES AN EXISTING FIRE HYDRANT. PROVIDE AN EXTERIOR BARRIER FOR A WEATHER TIGHT AND CLOSED BUILDING LDH O <br /> CB TOP OF CATCH BASIN. SYSTEM. THE PANELING IS TO BE MINIMUM 26 GAGE THICKNESS WITH A G90 U � � H <br /> 1. AT START OF CONSTRUCTION; THE PROJECT'S CONTRACTOR TS CR CROWN OF ROAD. F—o DESIGNATES AN EXISTING POWER POLE WITH ANCHOR. GALVANIZED BASE. THE CONTRACTOR IS TO PROVIDE THE OWNER WITH A y+ <br /> W H <br /> TO REVIEW ALL EXISTING CONDITIONS ALONG WITH FIELD VERIFY / EP EDGE OF PAVEMENT. COLOR SELECTION CHART. SELECTED COLOR IS TO BE A BAKED-ON ENAMEL <br /> FINISH OF MINIMUM .001." THICKNESS ON THE EXTERIOR SIDE AND .0006" � ..1 FLI ��I�"`+}}} <br /> EXPOSE ALL ELECTRICAL / SEWER / WATER / GAS TIE-TNS TO FF FINISH FLOOR. ® DESIGNATES AN EXISTING ELECTRICAL VAULT, w <br /> VERIFY THEIR EXISTING LOCATIONS, SIZE AND INVERT FOR FH FIRE HYDRANT. THICKNESS ON THE INTERIOR SIDE. O <br /> H) FLASHING, TRIM, SEALANT, MASTIC, CAULKING, AND CLOSURES, AS a4 <br /> G FINISH GRADE. �� DESIGNATES AN EXISTING GAS METER. <br /> COMPLIANCE WITH THE REQUIREMENTS OF THE PROJECT. REQUIRED BY THE SBM, ARE TO BE INCLUDED AND INSTALLED TO ACHIEVE A 0n . l <br /> INV PIPE INVERT. WEATHER TIGHT AND CLOSED BUILDING SYSTEM. ALL APPLICATIONS OF pP., W O a <br /> 2. THE PROJECT'S TEMPORARY BENCH MARK #1; CHISELED SQUARE PDMH PROCESS DRAIN MANHOLE. DESIGNATES EXISTING SUGAR TEST STAND FACILITY'S SEALANT, MASTIC AND CAULKING ARE TO ACHIEVE A MINIMUM 7 YEAR LIFE <br /> ON THE TOP OF CONCRETE PAD AT THE SOUTHWEST CORNER OF THE PP POWER POLE. EXISTING 6" PROCESS DRAIN LINE / EXISTING 2" EXPECTANCY OF 1000- PERFORMANCE. <br /> NOTED EXISTING MCC2, REFERENCE ELEVATION 100.00' . RIM TOP OF RIM. EXG 6"PD>/ EXG 2"NW / EXG E NON-POTABLE WATER LINE / EXISTING ELECTRICAL <br /> RTP TOP OF RAISED TANK PAD. SERVICE PER 05/12/16 JQBSITE MEETING WITH MR. STAN DIVISION 15 MECHANICAL / ELECTRICAL 0 REV DATE BY <br /> 3. THE PROJECT'S TEMPORARY BENCH MARK #2; CHISELED SQUARE SEP TOP OF BURIED SEPTIC TANK. HALL. a <br /> ON THE TOP OF CONCRETE PAD AT THE NORTHWEST CORNER OF WORK TBM#1 TEMPORARY BENCH MARK. REFER TO NOTE #2. 15000 GENERAL INFORMATION: <br /> AISLE NORTHWEST OF THE NOTED EXISTING TANK #2225 REFERENCE TBM#2 TEMPORARY BENCH MARK. REFER TO NOTE #3. DESIGNATE THE MAIN HIGH VOLTAGE BURIED ELECTRICAL A) THE PROJECT'S FLOOR PLAN LAYOUT BY ADVANCED DESIGN GROUP GOVERNS H <br /> ELEVATION 100.01' . EXG PG&E 411EC OVER ALL OTHER PLUMBING, MECHANICAL & ELECTRICAL FLOOR PLAN LAYOUTS <br /> TP TOP OF PAVING. SERVICE. <br /> WB EXISTING WATER DISTRIBUTION BOX. WITH RESPECT TO FRAMING LAYOUTS (WALT, LOCATIONS, DOOR SWINGS, ETC,..) . <br /> rr B) UNLESS NOTED; THE PLUMBING, MECHANICAL AND ELECTRICAL <br /> 4 . SHADED AREA DESIGNATES THE LOCATION OF THE PROPOSED WR EXISTING 8 WATER RISER. DESIGNATES AN EXISTING LEACH FIELD DISTRIBUTION <br /> PRODUCTION BUILDING. REFER TO SHEET 3 FOR THE PROJECT'S +C � CONTRACTORS ARE NOT TO CUT OR FIELD MODIFY AND STRUCTURAL ITEMS OF a <br /> BOX WITH MANHOLE LTA. <br /> SITE PLAN. as•aa DESIGNATES EXISTING GRADE ELEVATIONS. THE PROJECT WITHOUT CONFIRMATION FROM ADVANCED DESIGN GROUP. IF <br /> DESIGNATES AN EXISTING SITE CATCH BASIN. THERE ARE ANY QUESTIONS OR CONCERNS, PLEASE CONTACT ADVANCED DESIGN <br /> DESIGNATES A FINISH GRADE FLOW ARROW. GROUP (209) 577-3108. <br /> 5. REFER TO SHEET 4a FOR THE PROJECT'S SITE GRADING & C) UNLESS NOTED; PLUMBING LINES ARE NOT PERMITTED WITHIN ANY <br /> DRAINAGE PLAN. DESIGNATES AN EXISTING 6' HIGH WOVEN WIRE FENCE CONCENTRATED FOOTING WITHOUT CONFIRMATION FROM ADVANCED DESIGN z <br /> DESIGNATES AN EXISTING 6' HIGH WOVEN WIRE FENCE, AND GATE THAT ARE TO BE REMOVED AND RELOCATED. GROUP. IF THERE ARE ANY QUESTIONS OR CONCERNS, PLEASE CONTACT <br /> 3108 <br /> 9 <br /> 2 <br /> REFER TO THE PROJECT'S SITE PLAN FOR THE FENCE'S. & ADVANCED DESIGN GROUP ( 0 ) 577- . <br /> 6, REFER TO SHEET 4b FOR THE PROJECT'S SITE UNDERGROUND TYP WHERE NOTED <br /> Pte. GATE'S NEW LOCATION. D} PRIOR TO CONSTRUCTION; THE PLUMBING CONTRACTOR IS TO CONFIRM ALL o -- <br /> DESIGNATES AN EXISTING 6' HIGH WROUGHT IRON FENCE, FIXTURES FOR TYPE & STYLE WITH OWNER PRIOR TO ORDERING., DRATnTN BY: BAO <br /> 7 . THE NOTED EXISTING SEPTIC & LEACH FIELD SYSTEM WAS TYP WHERE NOTED. d DESIGNATES EXISTING DECIDUOUS TREE. E) ALL UNDERGROUND WORK FOR ELECTRICAL, PLUMBING, ETC... IS TO HAVE <br /> „ THEIR RESPECTIVE TRENCHES RECOMPACTED PRIOR TO POUR OR PAVING. W CHECKED BY: EH <br /> 9 DERIVED FROM THE SAN JOAQUIN COUNTY'S ONSITE WASTEWATER REFER TO SPEC. 02200 FOR COMPACTION REQUIREMENTS. ***WARNING*** AT z <br /> 'TREATMENT SYSTEM PERMIT" (#SR0032860 DATED 02/24/03) AND ® DESIGNATES AN EXISTING DISABLED ACCESS PARKING. DESIGNATES EXISTING EVERGREEN TREE {QUANTITY & � <br /> LOCATION ESTIMATED) . START OF CONSTRUCTION; CONTRACTOR IS TO REVIEW / FIELD VERIFY / <br /> FIELD REVIEW BY ADVANCED T�ESIGI GFtOtTP. NOTE THE FOLLOWING; [DATE. 07/25/16 <br /> ` # r-4 <br /> A} EXISTING PERMIT NOTED 7a DESIGN BASED UPON 100 EXG $rrNW— DESIGNATES AN EXISTING NDN POTABLE WATER LINE EXPOSE ALL ELECTRICAL / SEWER / WATER / GAS TIE-INS TO VERIFY THEIR <br /> EMPLOYEES.) EXISTWITH SIZE NOTED. EXISTING LOCATIONS, SIZE AND INVERT FOR COMPLIANCE WITH THE <br /> REQUIREMENTS OF THE PROJECT- UNLESS NOTED; THE FOLLOWING MINII4UM z SCALE: AS NOTED <br /> B) RECONFIRMING 05/06/16 PHONE CONVERSATION WITH MR. DESIGNATES AN EXISTING SANITARY LEACH FORCE MAIN BURIAL COVER (ABOVE PIPE) IS TO BE MAINTAINED (REFER TO SPEC 15000E <br /> CRAIG ROUS, DIRECTOR OF OPERATIONS & PLANNING; THE LINE WITH SIZE NOTED PER 05/12/16 JOBSITE MEETING FOR WATER LINES GREATER THAN 3" PIPE) v <br /> MAXIMUM SITE EMPLOYEES PER SHIFT IS 40. " TYPE MATERIAL --TRAFFIC/FLOOR AREALANDSCAPEDAREA p RQ JE C T <br /> >✓XG 2 SLFM _ WITH MR. STAN HALL. NOTE THAT THIS LINE IS TO BE ---- -------____.._- �� H -: <br /> -<-7T= ABANDONED IN P=C T ABANDONED IN PLACE. REFER TO THE PROJECT'S SITE SEWER ABS/PVC 20 12 <br /> DRAINAGE / UNDERGROUND PLAN, SHEET 4, FOR THE NEW <br /> SEWER IRON ----------- 12" ------------ - 12�, o <br /> LOCATION OF THE SANITARY LEACH FORCE MAIN LINE. WATER PVC/IRON 24 24 0 <br /> GAS IRON ----------- 24" --------------- 24" Q 16013A <br /> DESIGNATES AN EXISTTNG WATER LINE WITH SIZE NOTED ELECT PVC ------------ 24" -------------- 24" <br /> -EXG 6"W— PER 05/12/16 JOBSITE MEETING WITH MR. STAN HALL. F) REFER TO SECTION 1011 OF THE 2013CBC FOR THE EXIT ILLUMINATION <br /> REQUIREMENTS. z <br /> G) REFER TO SECTION 1011 OF THE 2013CBC FOR EXIT SIGN REQUIREMENTS. H <br /> DESIGNATES AN EXISTING TELEPHONE LINE PER 05/32/16 H) REFER TO CHAPTER 12 OF 2013CBC FOR VENTILATION REQUIREMENTS. w <br /> EXG T JOBSITE MEETING WITH MR. STAN HALL THAT IS TO BE I) ALL OUTDOOR LIGHTING SHALL BE APPROVED BY THE PLANNING DIRECTOR Q SHEET NUMBER <br /> MAINTAINED. PRIOR TO INSTALLATION AND SHALL BE SHIELDED FROM ADJACENT PROPERTIES <br /> AS REQUIRED BY THE PLANNING DIRECTOR. <br /> DESIGNATES AN EXITING SANITARY SEWER LINE WITH <br /> -� EXG 4"SS SIZE NOTED (FIELD VERIFY) . <br /> i <br /> _ ....._ .......... <br /> . _..-_ ......... <br /> JOAQUIN COUNTY S APPROVEDT ' DRAB i <br /> N NOTE " � IT �. S _ . S <br /> VERIFY <br />