Laserfiche WebLink
0 <br />n <br />II <br />%I <br />1 <br />0 <br />u <br />0 <br />11 <br />i <br />PROPERTY LINE <br />� tS l3AfmIIzI <br />PROPERTY LINE <br />SEE SHEET No. C2.1 <br />SDCO <br />22LF 6"SD <br />67.4E <br />1 LF 8"SD S <br />SDCO <br />2LF B"SD <br />67.46FL <br />12LF 6"SD S= <br />SDCO <br />71.24 <br />SDCO <br />12LF 6"SD <br />2LF 8"SD <br />SDCO <br />67.77 <br />1 L 8"SD <br />67.76FL( <br />22LF 6"SD ' <br />SDCO <br />20 <br />10 <br />0 <br />20 <br />FILE# XX -XX <br />IDENTIFICATION STAMP <br />IHV. OF THE STATE ARCHITECT <br />OFTICE OF REGULATION SERVICES <br />APPL.# 02-115513 <br />O <br />ONSITE SEPTIC <br />SYSTEM PLAN <br />1" <br />= 20' <br />DRAWING <br />NUMBER.�2 <br />■ <br />KEY NOTES <br />THIS PIAN SEF SHALL ONLY BE UTILIZED TO CONSTRUCT THE SEPTIC <br />SYTEM IMPROVEMENTS. <br />CONTRACTOR SHALL REVIEW PLAN SET TIM "CML IMPROVEMENT <br />PLANS FOR COLONY OAK K-8 SCHOOL, RIPON UNIFlED SCHOOL <br />DISTRICT, CALIFORNIA" PERPARED BY NORTHSTAR ENGINEERING GROUP <br />FOR ALL OTHER CML IMPROVEMENTS. IF A CONFLICT IS FOUND <br />BETWEEN "CML IMPROVEMENT PLANS FOR COLONY OAT( K-8 SCHOOL, <br />RIPON UNIFIED SCHOOL DISTRICT, CALIFORNIA" AND THIS PLAN SET, <br />CONTRACTOR SHALL CONTACT ENGINEER IMMEDIATELY. <br />® CONTRACTOR SHALL INSTALL SEWER CLEANOUT PER SAN JOAQUIN <br />COUNTY STANDARDS WITH APPROPRIATE FITTINGS AND REDUCER. <br />CONTRACTOR SHALL VERIFY THE LOCATIONS OF THE UTILITY <br />CONNECTIONS WITH THE PLUMBING PLANS PRIOR TO CONSTRUCTION OF <br />PROPOSED STUBS AND STUB 5 FEET FROM THE FACE OF THE <br />BUILDING. <br />® CONTRACTOR SHALL INSTALL SEWER MANHOLE PER SAN JOAQUIN <br />COUNTY STANDARDS AND SPECIFICATIONS. <br />® CONTRACTOR SHALL EXCAVATE EXISTING SEWER UNE TO VERIFY THE <br />HORIZONTAL AND VERTICAL ALIGNMENT PRIOR TO THE INSTALLATION OF <br />THE SEWER STRUCTURE/PIPE CONTRACTOR SWUl INFORM THE <br />ENGINEER IF THE ALIGNMENTS ARE DIFFERENT THAN SHOWN. <br />CONTRACTOR SHALL CONNECT TO STUB PER SAN JOAQUIN COUNTY <br />STANDARDS AND SPECIFICATIONS. <br />® CONTRACTOR SHALL INSTALL SEWER CLEANOUT PER SAN JOAQUIN <br />COUNTY STANDARD DRAWINGS AND SPECIFICATIONS. SEE DETAIL ON <br />SHEET C1.2 FOR ADDITIONAL INFORMATION. <br />CONTRACTOR SHALL INSTALL 4,000 GALLON PRIMARY SEPTIC TANK PER <br />SAN JOAQUIN COUNTY STANDARD DRAWINGS AND SPECIFICATIONS. SEE <br />DETAIL ON SHEET C1.2 FOR ADDITIONAL INFORMATION. <br />(E) CONTRACTOR SHALL INSTALL SEWER LEACH FIELD IN ACCORDANCE WITH <br />SAN JOAQUIN COUNTY STANDARDS AND SPECIFICATIONS. SEE DETAILS <br />ON SHEET C1.2 FOR CALCULATIONS AND ADDITIONAL INFORMATION. <br />CONTRACTOR SHALL COORDINATE WITH SAN JOAQUIN COUNTY FOR ANY <br />INSPECTION DURING CONSTRUCTION BY COUNTY PERSONNEL <br />® PROPOSED 100% LEACH FIELD EXPANSION AREA PER SAN JOAQUIN <br />COUNTY STANDARDS AND SPECIFICATIONS. <br />® 150 FEET WATER WELL SETBACK RADIUS LINE. <br />m CONTRACTOR SHALL "USE DME CAUTIONS WHEN INSTALLING SEWER <br />NEAR EXISTING UTILITIES. CONTRACTOR SHALL ENSURE THAT THERE IS <br />ADEQUATE SEPARATION BETWEEN THE PROPOSED SEWER AND EXISTING <br />UTILITIES. CONTRACTOR SHALL NOTIFY ENGINEER IN THE EVENT OF ANY <br />CONFLICT. <br />® *USE EXTREME CAUTIONS TO AVOID UNDERGROUND UTILITIES WHEN <br />INSTALLING FOOTINGS FOR WALLS AND FENCES AT ALL UTILITY <br />WALL/FENCE CROSSING. <br />m CONTRACTOR SHALL INSTALL OBSERVATION WELL PER DETAIL ON SHEET <br />C1.2. <br />® CONTRACTOR SHALL INSTALL SANITARY SEWER LIFT STATION PER <br />MANUFACTURER RECOMMENDATIONS AND SAN JOAQUIN COUNTY <br />STANDARD DRAWINGS AND SPECIFICATIONS. SEE DETAILS ON SHEET <br />C1.2 FOR ADDITIONAL INFORMATION. <br />® CONTRACTOR SHALL INSTALL VALVE VAULT TO MERGE DUAL DISCHARGE <br />PIPES PER MANUFACTURER'S RECOMMENDATIONS. SEE SHEET CI.2 FOR <br />ADDITIONAL INFORMATION. <br />® CONTRACTOR SHALL INSTALL UFT STATION CONTROL PANEL PER <br />MANUFACTURER'S RECOMMENDATIONS. SEE DETAILS ON SHEET C1.2 <br />FOR ADDIBONAL INFORMATION. <br />® CONTRACTOR SHALL INSTALL FLOW METER. <br />® CONTRACTOR SHALL INSTALL INSPECTION PIPE AT END OF EACH LEACH <br />LINE PER SAN JOAQUIN COUNTY STANDARDS. SEE DETAIL ON SHEET <br />C1.2. <br />m CONTRACTOR SHALL INSTALL DISTRIBUTION BOX WITH TRIMMER VALVE <br />PER SAN JOAQUIN COUNTY STANDARDS. <br />COPYRIGHT 2017 NORTHSTAR ENGINEERING GROUP, INC I <br />CLIENT FOCUSED • PASSION DRIVEN <br />NORTHERN CALIFORNIA <br />1110 IRON POINT ROAD, SUITE 200 <br />FOLSOM <br />CALIFORNIA 95630-8301 <br />TEL: 916-355r9922 <br />www.wlcarchitects.can <br />w J <br />00 <br />LL0 <br />Z <br />U) <br />J 00 <br />W 1 <br />Q <br />U) 0 <br />>111111111 <br />V0 <br />H J <br />a0 <br />W V <br />t!) <br />TsASr- --- o <br />o :o <br />SHEE-f No. a __._ six <br />C2.1 <br />SHEET No. <br />C2.2 <br />KEY PLAN <br />Max Ivan Medina <br />C-24882 <br />kYt O6 -3a17 <br />CONSULTANT <br />Bingin�ring Getup/ Into. <br />• CML ENGWEMNG " SURVEnNG " PLMANNG <br />620 12th Sheet Modesto. CA 95354 <br />(209) 524-3525 Phone (209) 524-3526 Fox <br />DATE: 10-061-17 <br />O <br />FILE# XX -XX <br />IDENTIFICATION STAMP <br />IHV. OF THE STATE ARCHITECT <br />OFTICE OF REGULATION SERVICES <br />APPL.# 02-115513 <br />O <br />ONSITE SEPTIC <br />SYSTEM PLAN <br />= <br />DRAWING <br />NUMBER.�2 <br />■ <br />U <br />a <br />U�w <br />0 <br />U <br />o <br />Lu <br />E <br />Q <br />LL <br />U <br />Z <br />z <br />— <br />00 <br />NO <br />Z <br />BY <br />it <br />O^ <br />I..L� <br />I..L <br />TsASr- --- o <br />o :o <br />SHEE-f No. a __._ six <br />C2.1 <br />SHEET No. <br />C2.2 <br />KEY PLAN <br />Max Ivan Medina <br />C-24882 <br />kYt O6 -3a17 <br />CONSULTANT <br />Bingin�ring Getup/ Into. <br />• CML ENGWEMNG " SURVEnNG " PLMANNG <br />620 12th Sheet Modesto. CA 95354 <br />(209) 524-3525 Phone (209) 524-3526 Fox <br />DATE: 10-061-17 <br />SCALE: AS SHOWN <br />FILE# XX -XX <br />IDENTIFICATION STAMP <br />IHV. OF THE STATE ARCHITECT <br />OFTICE OF REGULATION SERVICES <br />APPL.# 02-115513 <br />AC FLS SS <br />DATE <br />ONSITE SEPTIC <br />SYSTEM PLAN <br />DRAWING <br />NUMBER.�2 <br />■ <br />NO <br />DATE <br />BY <br />DESCRIPTION <br />REVISIONS <br />DRAWN: CRW <br />CHECKED: JPE <br />DATE: 10-061-17 <br />SCALE: AS SHOWN <br />PROJECT NUMBER 1520100 <br />ONSITE SEPTIC <br />SYSTEM PLAN <br />DRAWING <br />NUMBER.�2 <br />■ <br />