<br /> /� 1.) THIS PROJECT SHALL COMPLY w/TITLE 24& 2013 CBC, APN It:
<br /> CRC, CGBS, CMC, CEC, CPC, CFC, 2008 CEES
<br /> Local jurisdiction is applicable to this project. BldnCt, Use: Residence
<br /> Stories: 1-story
<br /> 2.) Use Table R602.3(1,2,3,&4) Nailing Schedule.-I' Cons= Type' VB
<br /> 3.) Use 0.145 x 2 5/8" Power Driven Pins on conc. slab floors @ interior non-bearing walls, thruZonlrtty' AG4,0
<br /> -- , , — 2x PTMS plates into conc. slab floors @ 32" o.c. and with-in 12"from splices. Fasteners to be
<br /> 4x12 > F z s.<> 1F H.D. Galv., Stainless Steel, Silicon Bronze or Copper. Fnd. bolts 1/2" in dia. or more not included. OCCUy Grp R-3
<br /> All fieldcut ends, notches and drilled holes of preservative-treated wood shall be treated in field.
<br /> Seismic: p'�
<br /> 4.) All windows to be dual glazed vinyl. (See Energy Calcs. for SHGC's). Sleeping rms. and base- EXpQ, Q ml
<br /> Ii ment with no door egress shall have windows with a clear opening not greater than 44" from floor 12
<br /> k 8� and an openable area of at least 5.0 sq.ft. and 5.7 sq. ft. above the first floor w/the min. openable C lim�,te:
<br /> `– width of 20" and min. openable height of 24". Flood Zone: X (500)
<br /> 5) 110v Smoke Detectors to be battery backed, interconnected and audible in all sleeping areas. All Snom,f, Load: 16# Grn(
<br /> branch circuit outlets in dwelling unit family, dining, living, parlors, libraries, dens, bedrooms, sun- SW (Gr
<br /> rooms, recreation rooms, closet, hallways, or similar rooms and areas to be protected by Arc-Fault Soil:
<br /> Circuit Interrupter& Tamper Resistant. Dwellings with fuel burning appliances and/or attached Garages Struc. Val.: LL 20 Ps
<br /> to install 110v Carbon Monoxide Alarms that are battery backed & interconnected where more than one
<br /> is required, and placen each separate sleeping area in the immediate vicinity of the bedrooms and each Fire_d',prinl(IerS Yes
<br /> d i
<br /> floor level, including basements. Bathroom Exhaust Fans to be Energy Star compliant, ducted to exterior& Dwelling: 1572 Sq.
<br /> must be humidistat controlled capable of adjustment between a relative humidity range of 50% to 80%.
<br /> Provide an Energy Star continuous vent fan w/a labeled switch and 6" duct to exterior. Provide min, 4" Po rCl. 1092 Sq
<br /> Dryer vent exhaust duct to exterior limited to 14'w/2-elbows. Bath & Utility GFCI's to be 20 amp:dedicated --- -— ---
<br /> circuit. Lighting and other receptacles cannot be connected to a small applicance branch circuit. Provide a
<br /> metallic ground-bond at water and gas pipes. Any fixed appliance such as disposal, dishwasher, clothes
<br /> washer, dryer, built-in heaters, or any other fixed appliance with '/4 H.P. motor or larger shall be on a separate
<br /> #12 AWG wire branch circuit supplied with minimum#12 AWG wire and a 15 amp. indicating type switch. m,
<br /> Fixtures more than 6 Ibs.or measures more than 16" in any dimension shall not be mounted by the screw box '�� � w
<br /> alone. 220v appliances shall be 4-wire grnd.. Fluorescent screw type base bulb fixture is not permitted. l
<br /> Recessed can/lights shall be zero clearance insulation cover, use high efficacy lights in Kitchen & Utility Rm..
<br /> Use high efficacy lights or manuel-on occupancy in Bathrooms. Use high efficacy, manuel-on occupancy or
<br /> dimmer lights in Living Rm., Family Rm., Dining Rm., Bedrooms, Halls &Attic. Outdoor lighting attached to
<br /> buildings use High efficacy or controlled by motion-sensor+ photocontrol. Outdoor GFCI to be water-proof
<br /> in-use.
<br /> All appliance& roofing Manufacturer's,installation instructions to be on job site at time of inspection.
<br /> 6.) Thresholds at doorways shall not exceed 3/4" in height for sliding doors or 1/2"for other doors.
<br /> RE SPRINKLER SYSTEM Provide 36" min. depth landing @ exterior doors. l
<br /> 7.) Use 3/4" water Hose Bibbs with anti-backflow device, Use 1"water to Water Heater. Shower heads to be
<br /> 2.0 gpm- @ 80 psi w/Pressure-Balanced or Thermostatic Mix Valves 120 degress max., Lay.Faucet to be l ✓'
<br /> lod
<br /> ring fire sprinkler protection shall be 1.5 gpm. @ 60 psi, Kit& Utility Faucet to be 1.8 gpm. @ 60 psi:; water closets to be 1.28 flush cap. max. &
<br /> ccordance with the approiate NFPA shall require 15" net clear side. Potable water to be run in copper 4" sewer to first bath. F PO.w PN
<br /> ards 1313D or 13R by the California
<br /> installation contractor or a register- 8.) Exterior studs to be 9 '-2x4 @ 16" o.c. w/ Hardi-Plank siding o/ 15#o/sheathing. All sheathing shall extend
<br /> ion engineer and approved prior tofrom bottom plate to dbl. top plate U.O.N.
<br /> protet
<br /> ce of the building permit. 9.) When requested,'a TXV Diagnostic Testing for HVAC System and 4ucts is required to be verified by �•
<br /> an approved HERS Rater. : (Required for this Prosect) +
<br /> f
<br /> 10.) Cover heat&cooling duct openings and protect mechanical ecmenf from dust during construction: � � =N
<br /> 11 Thic nmiect shall comoly with the provisions of the Cahforn`iaBuilding Standards Code