My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
5475
>
2800 - Aboveground Petroleum Storage Program
>
PR0522614
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/3/2022 2:17:58 PM
Creation date
8/24/2018 6:01:49 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0522614
PE
2832
FACILITY_ID
FA0010103
FACILITY_NAME
XPO Logistics Freight, Inc.-UST
STREET_NUMBER
5475
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
17705028
CURRENT_STATUS
02
SITE_LOCATION
5475 S AIRPORT WAY
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\A\AIRPORT\5475\PR0522614\COMPLIANCE INFO 2004 - 2016.PDF
QuestysFileName
COMPLIANCE INFO 2004 - 2016
QuestysRecordDate
8/8/2017 5:33:55 PM
QuestysRecordID
3559707
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J OA U I Environmental Health Department <br /> COUNTY- <br /> - <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> XPO Logistics Freight, Inc.-UST 5475 S AIRPORT WAY, STOCKTON December 06, 2017 <br /> Other Violations <br /> 4030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 4040 See below Unlisted Release/Leaks/Spills violation ❑V ❑R ❑COS <br /> 4050 See below Unlisted Abandonment/Illegal Disposal/Unauthorized Treatment violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 102 CFR 112.3, 112.6 Failed to prepare a written SPCC Plan in accordance with CFR Part 112. <br /> This facility has an Aboveground Petroleum Storage Act (APSA) regulated shell capacity of 10,220 gallons (one <br /> 10,000 gallon diesel tank and four 55 gallon oil drums. A Spill Prevention, Control, and Countermeasure (SPCC) <br /> Plan was not available on site. All facilities which have an APSA regulated shell capacity of 1,320 gallons or greater <br /> shall prepare a written SPCC Plan which meets all of the requirements of the 40 CFR Part 112. This plan shall be <br /> certified by a professional engineer in accordance with 40 CFR 112.3(d). Immediately prepare a SPCC Plan in <br /> accordance with 40 CFR Part 112, which that includes all aboveground petroleum storage containers 55 gallons or <br /> larger. Submit a copy of the Professional Engineer (PE) certified SPCC Plan to the EHD for review. (This copy will <br /> be returned to the facility after review.) A copy shall be maintained on site at all times. <br /> This is a Class II violation. <br /> 201 CFR 112.3(d) Failure to have a licensed PE properly review and certify the SPCC plan. <br /> The Professional Engineer (PE) certification is incomplete. An SPCC PE certified plan was not found on site. The <br /> PE certification must include all of the aspects in 40 CFR 112.3(d)(1), including attesting that the PE is familiar with <br /> 40 CFR Part 112, he or his agent has visited and examined the facility, the Spill Prevention, Control, and <br /> Countermeasure (SPCC) Plan has been prepared in accordance with good engineering practice, including <br /> consideration of applicable industry standards, procedures have been established for required inspections and <br /> testing, and the Plan is adequate for the facility. Immediately obtain a complete PE certification for the facility's <br /> SPCC Plan. Submit a copy of the completed certification to the EHD. <br /> This is a Class II violation. <br /> 706 CFR 112.8(c)(2) Failed to provide and maintain adequate secondary containment. <br /> Four 55 gallon drums of product oil located near the truck wash area were observed with insufficient secondary <br /> containment. The vehicle wash area drain was downgrade and approximately twenty feet away from the drums. <br /> The secondary containment provided for each 55 gallon drum could not contain the entire capacity of the drum if it <br /> leaked. All bulk storage containers must be provided with a secondary means of containment for the entire capacity <br /> of the container and sufficient freeboard to contain precipitation. Immediately provide sufficient secondary <br /> containment for this and all other petroleum containers and tanks at this facility. <br /> This is a Class II violation. <br /> FA0010103 PR0522614 SCO01 12/06/2017 <br /> EHD 28-01 Rev.12/06/2021 Page 4 of 5 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />