Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENIO <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.oro/ehd <br /> ABOVEGROUND PETROLEUM STORAGE ACT (APSA) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> FacilSwift Transportation Facility : 901 D'arc Parkway InspectionectionName AddressDa : <br /> 5/19/2010 <br /> VIOLATIONS <br /> # v t", Code Section HSC=CA Health and Safe Code;CFR=Code of Federal Re ulatians;V=Violation;RV=Repeat violation <br /> S edfic requirements of HSC 26270.4.5(a)are identified as CFR code sections bepinning with 112 <br /> Failed to:test each aboveground container for integrity on a regular schedule or when repairs were made; <br /> 48 x CFR 112.8(c)(6) inspect containers and container supports;or keep records of inspections and tests,or provide <br /> equivalence as allowed b CFR 112.7 a 2 <br /> 49 CFR 112.8(c)(7) Failed to provide effective leakage control through defective internal heating coils,or provide equivalence <br /> as allowed by CFR 112.7(a)(2) <br /> 50 CFR 112.8(c)(8) Failed to install and regularly test approved liquid level sensing devices,or provide equivalence as allowed <br /> by CFR 112.7(a)(2) <br /> 51 CFR 112.8(c)(9) Failed to observe effluent treatment facility frequently enough to detect system upsets that could cause a <br /> dischar e,or Drovide equivalence as allowed by CFR 112.7(a)(2) <br /> 52 CFR 112.8(c)(10) Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas,or provide <br /> equivalence as allowed by CFR 112.7(a)(2) <br /> 53 CFR 112.8(c)(11) Failed to locate portable containers to prevent discharge or provide sufficient secondary containment <br /> capacity that will hold the volume of the largest container plus sufficient freeboard to contain precipitation <br /> Failed to provide buried piping with a protective wrapping and coating and cathodic protection and/or <br /> 54 CFR 112.8(d)(1) inspect buried piping for corrosion damage when exposed,or provide equivalence as allowed by CFR <br /> 112.7(a)(2) <br /> 55 CFR 112.8(d)(2) Failed to cap or blank-flange terminal connection at transfer point and mark its origin when piping is not in <br /> service Orin standby service for an extended time,or provide equivalence as allowed by CFR 112.7(a)(2) <br /> 56 CFR 112.8(d)(3) Failed to design pipe supports to minimize abrasion and corrosion and to allow for expansion and <br /> contraction,or provide equivalence as allowed by CFR 112.7(a)(2) <br /> 57 CFR 112.8(d)(4) Failed to regularly inspect aboveground valves,piping,and appurtenances,or provide equivalence as <br /> allowed by CFR 112.7(a)(2) <br /> 58 CFR 112.8(d)(4) Failed to conduct integrity and leak test for buried piping at time of installation,modification,construction, <br /> relocation,or replacement,or provide equivalence as allowed by CFR 112.7(a)(2) <br /> 59 CFR 112.8(d)(5) Failed to provide adequate warnings to vehicles entering facility to protect aboveground piping and other <br /> oil transfer o erations,or provide equivalence as allowed b CFR 11 2.7 a 2 <br /> 999 Other: See attached"Continuation-Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS ll, or MINOR-Notice to Comply) <br /> All violations are currently Minor. <br /> #2 Failed to conduct periodic inspections of the storage tank to assure compliance with CFR 112. <br /> #48 Failed to: test each aboveground container for integrity on a regular schedule or when repairs were <br /> made; inspect containers and container supports; or keep records of inspections and tests, or provide <br /> equivalence as allowed by CFR 112.7(a)(2). <br /> At time of inspection facility was not following listed testing and inspection schedule as described in <br /> SPCC. Begin implementing practices listed in SPCC plan. <br /> #10 Failed to complete a review and evaluation of SPCC plan at least once every five years. <br /> SPCC plan was prepared in July 2001 and has not been reviewed since. This plan is outdated and <br /> contains several errors. A complete review and evaluation of this plan is necessary. Immediately review <br /> and update this plan according to CFR 112. <br /> Complete and submit the Return to Compliance certification to this office within 30 days (June 20, 2010), <br /> with a statement addressing how each of the above noted violations have been corrected. The updated <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE($115). <br /> THIS FACILITY IS SUBJECT TO REINSP T N AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Inep Phone: Rete y nee: <br /> (209)953-7699 e4w t!Q Y <br /> EHD 28M2 ev 2! 10 Page 3 APSA ASPECTION REPORT <br />