My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ESCALON BELLOTA
>
4469
>
2800 - Aboveground Petroleum Storage Program
>
PR0540158
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/5/2019 4:10:23 PM
Creation date
8/24/2018 6:19:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0540158
PE
2832
FACILITY_ID
FA0019881
FACILITY_NAME
FARMINGTON CIRCLE K
STREET_NUMBER
4469
Direction
S
STREET_NAME
ESCALON BELLOTA
STREET_TYPE
RD
City
FARMINGTON
Zip
95230
APN
18713010
CURRENT_STATUS
01
SITE_LOCATION
4469 S ESCALON BELLOTA RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
EJimenez
Supplemental fields
FilePath
\MIGRATIONS\E\ESCALON BELLOTA\4469\PR0540158\COMPLIANCE INFO 2016 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
10/14/2016 10:50:47 PM
QuestysRecordID
3022137
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
119
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AFFORDA-TE$T <br /> 416 2nd Street Galt,Ca.95632 AST TANK TESTMAY 2 4 2016 <br /> 209 744-0112 Fax 209 744-0116 PRIMARY & ANNULAR <br /> Site: SANGUINETTI CIRCLE K Test Date: 05/09/2016 <br /> Address: 4391 ESCALON BELLOTA RD <br /> City: FARMINGTON, CA 95230 Equipment: VACUUM TEST GAUGE, <br /> Test Method Developed By: Tank Manufacturer Industry Standard XXX Professional Engineer <br /> Other(Specify): <br /> Test Method Uses: Pressure Vacuum XXX Hydrostatic Other(Spec): <br /> Measuring Equipment Used for Testing:VACUUM GAUGE, VACUUM PUMP, ISOLATION EQUIPMENT <br /> Tank#4 Tank#5 Tank#6 Tank# <br /> ® PRIMARY ® PRIMARY ❑ PRIMARY ❑ PRIMARY <br /> ❑ ANNULAR ❑ ANNULAR ® ANNULAR ❑ ANNULAR <br /> Tank Capacity: 5,000 15,000 ANNULAR <br /> D W- STEEL D W - STEEL D W - STEEL <br /> Tank Material: <br /> E-85 DIESEL 2 DRY <br /> Product Stored: <br /> Wait time between applying <br /> Pressure/vacuum/water and starting SET UP -- -- <br /> test: <br /> 1107 1115 0925 <br /> Test Start Time: <br /> -1.21 -1.14 -1.02 <br /> Initial Reading Ri): <br /> 1207 1215 1025 <br /> Test End Time: <br /> -1.21 -1.13 -1.02 <br /> Final Reading(Rf): <br /> HOUR HR HR <br /> Test Duration: <br /> .00 .01 .00 <br /> Chane in Readin -Ri: <br /> -.10 -.10 -.10 <br /> Pass/Fail Threshold: <br /> PASS PASS PASS <br /> Test Result: <br /> NO NO YES <br /> Was sensor removed for testing? <br /> Was sensor properly replaced after <br /> testing? N/A N/A YES <br /> Comments Technician: ZANE NIMMO <br /> OTTL#04-1676 ICC 5263322-UT ICC 5263322-U3 <br /> Oregon UST Service#26755 Oregon UST Tank Tightness#26756 <br /> Nevada UT-2206 <br /> Signature: <br /> Date: 5/9/2016 <br />
The URL can be used to link to this page
Your browser does not support the video tag.