My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ESCALON BELLOTA
>
4469
>
2800 - Aboveground Petroleum Storage Program
>
PR0540158
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/5/2019 4:10:23 PM
Creation date
8/24/2018 6:19:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0540158
PE
2832
FACILITY_ID
FA0019881
FACILITY_NAME
FARMINGTON CIRCLE K
STREET_NUMBER
4469
Direction
S
STREET_NAME
ESCALON BELLOTA
STREET_TYPE
RD
City
FARMINGTON
Zip
95230
APN
18713010
CURRENT_STATUS
01
SITE_LOCATION
4469 S ESCALON BELLOTA RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
EJimenez
Supplemental fields
FilePath
\MIGRATIONS\E\ESCALON BELLOTA\4469\PR0540158\COMPLIANCE INFO 2016 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
10/14/2016 10:50:47 PM
QuestysRecordID
3022137
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
119
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department 3 I Ilw <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209) 468-3433 Web:www.sagov.or_/q ehd <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> FARMINGTON CIRCLE K 14469 S ESCALON BELLOTA BLVD, February 16 2016 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 720 CFR 112.8(c)(11) Failed to provide sufficient secondary containment capacity for mobile or portable containers. <br /> The black steel 55 gallon drum of fuel contaminated test waters was observed with no secondary containment. <br /> Portable oil storage containers must be positioned or located to prevent a discharge and shall be furnished with a <br /> secondary means of containment sufficient to contain the capacity of the largest single container with sufficient <br /> freeboard to contain precipitation. Immediately provide sufficient secondary containment for this and all other portable <br /> containers at this facility, or provide equivalence as allowed by CFR 112.7(a)(2). <br /> This is a Class II violation. <br /> 721 CFR 112.8(c)(11) Failed to locate mobile or portable containers to prevent discharge. <br /> The black steel 55 gallon drum of fuel contaminated test water was not located to prevent a discharge. Portable oil <br /> storage containers must be positioned or located to prevent a discharge and shall be furnished with a secondary <br /> means of containment sufficient to contain the capacity of the largest single container with sufficient freeboard to <br /> contain precipitation. Immediately relocate these and all other portable containers at this facility to prevent a <br /> discharge. <br /> This is a Class II violation. <br /> 726 CFR 112.8(d)(4) Failed to regularly inspect aboveground valves, piping, and appurtenances. <br /> No inspection records were found for aboveground valves, piping and appurtenances. All aboveground valves, piping, <br /> and appurtenances shall be regularly inspected. Immediately inspect aboveground valves, piping, and appurtenances <br /> and ensure inspections are done regularly, or provide equivalence as allowed by CFR 112.7(a). <br /> This is a Class II violation. <br /> 727 CFR 112.8(d)(4) Failed to conduct integrity and leak test on buried piping any time it is worked on. <br /> No integrity test results were found on site for buried piping. Buried piping shall be tested for integrity and leaks at the <br /> time of installation, modification, construction, relocation, or replacement. Immediately perform integrity and leak <br /> testing of this piping and ensure that piping is tested when required, or provide equivalence as allowed by CFR <br /> 112.7(a)(2). <br /> This is a Class II violation. <br /> 728 CFR 112.8(d)(5) Failed to adequately warn vehicles entering facility to protect piping and other transfer operations. <br /> No warnings were observed on site to warn vehicles of aboveground piping, containers, or other appurtenances. <br /> According to the plan, warning sites are posted at the aboveground tanks A warning must be provided to all vehicles <br /> entering the facility to be sure that no vehicle will endanger aboveground piping or other oil transfer operations. <br /> Immediately provide a warning in accordance with CFR Part 112 for all vehicles entering the facility, or provide <br /> equivalence as allowed by CFR 112.7(a)(2). <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Page 7of8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.