My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
5000
>
2800 - Aboveground Petroleum Storage Program
>
PR0527046
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2021 3:08:23 PM
Creation date
8/24/2018 6:22:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0527046
PE
2832
FACILITY_ID
FA0003907
FACILITY_NAME
PANELLA TRUCKING LLC
STREET_NUMBER
5000
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95215
APN
14330001
CURRENT_STATUS
01
SITE_LOCATION
5000 E FREMONT ST
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FREMONT\5000\PR0527046\COMPLIANCE INFO 2007 - 2013.PDF
QuestysFileName
COMPLIANCE INFO 2007 - 2013
QuestysRecordDate
9/7/2017 8:15:53 PM
QuestysRecordID
3628440
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
74
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I*v <br /> Email from Raymond von Flue below: <br /> Luis, <br /> 1. Upon reviewing the second draft of the used oil tank assessment for Panella Trucking,more items <br /> were found to be missing or need more clarification: <br /> 1. Remaining service life of tank: What does 50 years with maintenance mean? What type of <br /> maintenance? Does 50 years include the 15 years already used or is it 50 years from the date of the <br /> assessment? The manufacture states that the tank life for this type of use, is 50 years from the date of <br /> manufacture with proper corrosion protection (Painting). If corrosion appears, the area should be <br /> cleaned to bare metal,primed and painted with a suitable coating. <br /> 2. Piping: What type of material? What are the lengths(Fill and Drain)? What are the volumes? <br /> Piping must also be tested. Vacuum line is 1 Y2"schedule 40 about 4'long. Pressure side is 1 %z" <br /> single wire oil resistant rubber hose to top of tank than 1 %z"fill schedule 40 pipe. Volume 389 cubic <br /> inches. 1.7 gals. The drain or unloading line was tested with the tank for a pressure of 5 psi. <br /> 3. Secondary containment: Provide a brief description of materials and coatings used to prevent <br /> migration of wastes from the area Provide a discussion of the compatibility and incompatibility of <br /> the containment surface with any waste it may come in contact with. What does the statement in the <br /> assessment „ all impediments in the concrete block have been sealed with a suitable sealant to <br /> prevent leakage” mean? The containment is by a voids felled reinforced concrete block wall that is <br /> unlined. All concrete is permeable to any liquid but concrete has a very low rate ofpermeability. <br /> Any spills would be discovered long before diesel or used oil could penetrate the 8"concrete block <br /> wall or the concretefloor. All penetrations are caulked with sealant <br /> 4. Clarification of secondary containment calculations:tank volume calculations must include <br /> acillary equipment and piping affiliated with the tank. Please relabel volume calculations as shown in <br /> the model assessment(a) 10%of aggregate volume, (b)volume of largest tank with the boundary,©) <br /> Volume from a 24hr., 25-year storm,(d)calculated volume of area and arrange data as {Larger of(a) <br /> or(b)} + {Containment area x©)) must be<(d)See mathcad sheet attached <br /> 5. Provide a brief description of the site security,Title 22,section 66265.14. <br /> The site is fenced and there is a watchmen on duty 24/7 <br /> If you have any questions,please feel fiee to give me a call. <br /> Raymond von Fliie <br /> Senior Registered Environmental Health Specialist <br /> San Joaquin County <br /> Environmental Health Department <br /> 600 E. Main St. <br /> Stockton CA 95202 <br /> Voice: (209)468-9848 Fax: (209)468-3433 <br /> 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.