Laserfiche WebLink
• <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.siooy.orq/ehd <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> GEMCO RIPON TRUCK PLAZA INC 1 1022 E FRONTAGE RD, RIPON October 10,2017 <br /> SPCC Plan Requirements for Onshore Facilities (excluding production facilities) <br /> 704 CFR 112.8(b)(5) Failed to provide two lift pumps for more than one continuous treatment unit o V o R o COS <br /> 705 CFR 112.8(c)(1) Container not compatible with oil stored and/or storage conditions o V o R o COS <br /> 706 CFR 112s(c)(2) Failed to provide and maintain adequate secondary containment .V .R o COS <br /> 707 CFR 112.8(c)(3) Failure to follow the criteria of this section while allowing drainage of uncontaminated rainwater o V o R o COS <br /> 708 CFR 112.8(c)(3)(iv) Failed to maintain records of drainage from diked areas in V o R o COS <br /> 709 CFR 112.8(c)(5) Failed to provide corrosion protection for partially buried tanks u V o R o COS <br /> 710 CFR 112.8(c)(6) Plan failed to adequately discuss procedures to test or inspect each container for integrity .V .R o COS <br /> 711 CFR 112.8(c)(6) Failed to perform scheduled tank tests or inspections by appropriately qualified personnel o V o R o COS <br /> 712 CFR 112s(c)(6) Failed to test or inspect each container for integrity based on industry standards .V .R o COS <br /> 713 CFR 112.8(c)(7) Failed to provide effective leakage control from defective internal heating coils o V o R o COS <br /> 714 CFR 112.8(c)(8)(kiv) Failed to provide each container with a high level monitoring device .V o R in COS <br /> 715 CFR 112.8(c)(8)(v) Failed to regularly test liquid level sensing devices to ensure proper operation o V o R o COS <br /> 716 CFR 112.8(c)(9) Failed to observe effluent treatment frequently enough to detect potential discharge o V o R o COS <br /> 717 CFR 112A(c)(10) Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas .V .R o COS <br /> 718 CFR 112.8(c)(11) Failed to provide sufficient secondary containment capacity for mobile or portable containers .V o R o COS <br /> 719 CFR 112.8(c)(11) Failed to locate mobile or portable containers to prevent discharge o V o R o COS <br /> 720 CFR 112.8(d)(1) Failed to take mrrectwe action an buried piping when exposed for any reason o V o R o COS <br /> 721 CFR 112.8(d)(1) Failed to provide corrosion protection for buried piping o V o R o COS <br /> 722 CFR 112.8(4)(2) Failed to cep/blank-flange connection at transfer point and mark its origin if not in service o V o R o COS <br /> 723 CFR 112.8(d)(3) Failed to design pipe supports to minimize abrasion/comosion and to allow for expansion/contraction in V o R o COS <br /> 724 CFR 112.8(d)(4) Failed to regularly inspect aboveground valves,piping,and appurtenances .V r R u COS <br /> 725 CFR 112.8(d)(4) Failed to conduct integrity and leak testing on buried piping any time it is worked on .V .R o COS <br /> 726 CFR 112.8(d)(5) Failed to adequately warn vehicles entering facility to protect piping and other transfer operations .V o R o COS <br /> Other Violations <br /> 4010 See below Unlisted Administration/Documentation violation .V o R o COS <br /> 4020 See below Unlisted Training violation o V o R o COS <br /> 4030 See below Unlisted Operations/Maintenance violation c V c R ❑COS <br /> 4040 See below Unlisted Release/Leaks/Spills violation u V u R n COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS],CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> Overall Inspection Comments: <br /> An inspection checklist was provided to the facility operator at the time of inspection. The EHD will generate <br /> and provide a complete report to the facility operator. <br /> FMOM650 PRO516198 SC001 10/10/2017 <br /> EHD28-01 Rev.09/22116 Page 3 of Aboveground Petroleum Storage Act OIR <br />