My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
2650
>
2800 - Aboveground Petroleum Storage Program
>
PR0522313
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2019 4:44:14 PM
Creation date
8/24/2018 6:45:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0522313
PE
2832
FACILITY_ID
FA0003941
FACILITY_NAME
ORCHARD SUPPLY HARDWARE #1570
STREET_NUMBER
2650
STREET_NAME
MACARTHUR
STREET_TYPE
DR
City
TRACY
Zip
95376
APN
21307061
CURRENT_STATUS
01
SITE_LOCATION
2650 MACARTHUR DR STE A
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
EJimenez
Supplemental fields
FilePath
\MIGRATIONS\M\MACARTHUR\2650\PR0522313\COMPLIANCE INFO 2008 -2014.PDF
QuestysFileName
COMPLIANCE INFO 2008 -2014
QuestysRecordDate
5/24/2018 9:47:57 PM
QuestysRecordID
3900496
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJ O 1` Q U I `IA,II, Environmental Health Department <br /> COUNTY <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ORCHARD SUPPLY HARDWARE#1570 2650 MACARTHUR DR, TRACY August 09, 2018 <br /> Other Violations <br /> 4040 See below Unlisted Release/Leaks/Spills violation ❑V ❑R ❑COS <br /> 4050 See below Unlisted Abandon ment/lIlegal Disposal/Unauthorized Treatment violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 203 CFR 112.3 Failure to implement the SPCC Plan. <br /> Page 3 of the SPCC plan calls for the the deployment of a portable secondary containment structure during <br /> loading/unloading activities. The secondary containment structure is to contain the maximum capacity of a single <br /> compartment of the tanker truck servicing th facility. No such structure was observed at the facility and facility were <br /> unaware of such a structure.The owner or operator or an onshore or offshore facility subject to this section must <br /> prepare in writing and implement a Spill Prevention Control and Countermeasure Plan. Implement the SPCC plan <br /> as written or amend to plan to reflect the facilities procedures and practices. <br /> This is a minor violation. <br /> 301 CFR 112.5(a) Failed to amend Plan as necessary. <br /> The facility contacts and facility phone numbers need to be updated.The SPCC plan references Sears Holding <br /> Company Environmental Operations Manual and emergency contact phone numbers, Sears is no longer the parent <br /> company. The plan describes a 500 gallon used oil container as being single walled with a concrete dike as <br /> secondary containment, a 500 gallon used oil double walled was observed.The Spill Prevention, Control, and <br /> Countermeasure(SPCC)Plan must be amended when there is a change in the facility design, construction, <br /> operation, or maintenance that materially affects its potential for a discharge,within 6 months of the change, and <br /> implemented as soon as possible, not later than 6 months following preparation of the amendment. Immediately <br /> make all necessary amendments to the SPCC Plan to accurately represent the procedures and policies currently in <br /> place at the facility. <br /> This is a minor violation. <br /> 302 CFR 112.5(b) Failed to review Plan once every five years and/or implement any resulting amendments. <br /> The Spill Prevention, Control, and Countermeasure(SPCC)Plan was last reviewed on 9/12/2005. A review and <br /> evaluation of the SPCC Plan must be conducted at least once every 5 years. As a result of this review and <br /> evaluation,the SPCC Plan must be amended within 6 months of review, and recertified by a Professional Engineer <br /> if any technical amendments were made. Immediately conduct a review of the facility SPCC Plan and make any <br /> necessary amendments. <br /> This is a Class II violation. <br /> 618 CFR 112.7(e), 112.8(c)(6) Failed to keep records of procedures, inspections,or integrity tests for three years. <br /> None of the tanks are currently being inspected as per the SPCC plan. Inspections and testing shall be conducted <br /> on all aboveground liquid petroleum containers larger than 55 gallons, including all 55 gallon drums of oil. Records <br /> of these inspections and tests shall be signed by the appropriate supervisor or inspector and kept on site with the <br /> Spill Prevention, Control, and Countermeasure(SPCC) Plan for a period of three years. Immediately begin <br /> necessary testing and inspections for all Aboveground Petroleum Storage Act regulated containers and maintain on <br /> site with the SPCC Plan. <br /> This is a Class II violation. <br /> FA0003941 PR0522313 SCO01 08/09/2018 <br /> EHD 28-01 Rev.09/27/2018 Page 4 of 7 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.