Laserfiche WebLink
API 653 In-Service Inspection Report <br /> for <br /> Pacific Ethanol HMT Inspection <br /> Tank No. T-7702 august a,2013 <br /> Stockton, CA Page 26 of 41 <br /> 6.0 EQUIPMENT <br /> 6.1 ULTRASONIC <br /> UT equipment utilized for the inspection was a Panametrics EPOCH LT Flaw Detector. <br /> Transducer equipment utilized was a BRITEK 7.5 MHz, 0.312 inch dual element. <br /> Calibration block equipment utilized was a 5 step, 4340 carbon steel test block. <br /> Calibration block equipment utilized was a 5 step, 304 stainless steel test block. <br /> Echogel 20 was used as a couplant. <br /> 6.2 LEVEL <br /> Level equipment utilized was a Topcon Marksman RL-113C self-leveling rotating laser. <br /> R tt U L I"VE D <br /> AUG 14 2014 <br /> APIRP7NE.V70T REV 2 2326286817-7702r(Rev 1) 1 i/612013 2:13 PM <br /> ENVIRONMENTAL HEALTH <br /> DEPARTMENT <br />