Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3429 Fax: (209)468-3433 Web:www.siaov.org/ehd <br /> CONTINUATION FORM Page: 4 of <br /> OFFICIAL INSPECTION REPORT Date: 07/17/14 <br /> Facility Address: 3028 Navy Dr., Stockton Program: APSA <br /> SUMMARY OF VIOLATIONS <br /> CLASS I, CLASS II,or MINOR-Notice to Comply) <br /> 517. Copies of inspection and testing records for the monthly tank inspections were not found on site. <br /> The inspections being conducted are not covering all of the tanks and areas required. Inspections and <br /> tests must be conducted in accordance with the written procedures developed in the SPCC Plan. <br /> Records of these inspections and tests must be signed by the appropriate supervisor or inspector and <br /> kept on site with the SPCC Plan for a period of three years. Immediately locate a copy of all inspection <br /> and testing records for the last three years, maintain them on site, and submit copies to the EHD. <br /> 518. Records for annual SPCC training were not available on site. At a minimum, oil-handling <br /> personnel must be trained in the operation and maintenance of equipment to prevent discharges, <br /> discharge procedure protocols, applicable pollution control laws, rules & regulations, general facility <br /> operations, and the contents of the facility's SPCC Plan. Annual briefings must be conducted to assure <br /> adequate understanding of the SPCC Plan and highlight and describe any known discharges or failures, <br /> malfunctioning components, and any recently developed precautionary measures. Immediately conduct <br /> necessary training for all oil handling personnel. Submit copies of training records to the EHD. <br /> +609. Copies of integrity test records were not found on site. According to the Plan, all tanks are <br /> inspected on a 10 year schedule according to API 653 standards. All aboveground containers are to be <br /> inspected on a regular basis. Comparison records and other records of inspections and tests must be <br /> maintained on site with the SPCC Plan. Immediately locate a copy of all integrity inspection and testing <br /> records, maintain them on site, and submit copies to the EHD. <br /> REPEAT VIOLATION <br /> Notice to Comply - Minor violations: (501, 504, 505) <br /> 501. The cross reference for the SPCC Plan is not entirely accurate and does not always list specific <br /> locations. The listing for the facility maps was over 60 pages before the location of the maps in the Plan. <br /> If you do not follow the sequence specified in 40 CFR 112 for the Plan, you must prepare an equivalent <br /> Plan and supplement it with a section cross-referencing the location of requirements in 40 CFR 112 and <br /> the equivalent Plan. Immediately amend the Plan to include a cross-reference that lists the specific, <br /> accurate locations of the Plan requirements, or to follow the required sequence. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD Inspector: eeived py: Title: <br /> Stacy Rivera (209) 468-3440 <br /> EHD 23-02-093 Rev 04/19/12 CONTINUATION FORM <br />