Laserfiche WebLink
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Aboveground Petroleum Storage Act Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />DEFENSE DISTRIBUTION DEPOT/SAN <br />700 E ROTH RD LATHROP <br />June 24 2015 <br />SPCC Plan Requirements for Onshore Facilities (excluding production facilities) <br />723 <br />CFR 112.8(d)(1) <br />Failed to provide corrosion protection for buried piping <br />❑ V ❑ R ❑ COS <br />724 <br />CFR 112.8(d)(2) <br />Failed to cap/blank-flange connection at transfer point and mark its origin if not in service <br />❑ V ❑ R ❑ COS <br />725 <br />CFR 112.8(d)(3) <br />Failed to design pipe supports to minimize abrasion/corrosion and to allow for expansion/contraction <br />❑ V ❑ R ❑ COS <br />726 <br />CFR 112.8(d)(4) <br />Failed to regularly inspect aboveground valves, piping, and appurtenances <br />❑ V ❑ R ❑ COS <br />727 <br />CFR 112.8(d)(4) <br />Failed to conduct integrity and leak test on buried piping any time it is worked on <br />❑ V ❑ R ❑ COS <br />728 <br />CFR 112.8(d)(5) <br />Failed to adequately warn vehicles entering facility to protect piping and other transfer operations <br />❑ V ❑ R ❑ COS <br />Other Violations <br />4010 <br />See below <br />Unlisted Administration/Documentation violation <br />❑ V ❑ R ❑ COS <br />4020 <br />See below <br />Unlisted Training violation <br />❑ V ❑ R ❑ COS <br />4030 <br />See below <br />Unlisted Operations/Maintenance violation <br />❑ V ❑ R ❑ COS <br />4040 <br />See below <br />Unlisted Release/Leaks/Spills violation <br />❑ V ❑ R ❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS Il, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />102 <br />HSC 25270.4.5(a) Failed to properly close a tank that is considered permanently closed. <br />At the time of inspection: <br />1-12,000g Diesel AST at the fueling station <br />1-12,000g Gas AST at the fueling station <br />are not in use but have not been properly closed. When a tank is not in use, it must be permanently closed by <br />meeting the following conditions: <br />- remove all liquid and sludge from each container and connecting line <br />- disconnect and blank off all connecting lines and piping have from the tank <br />- close and lock all valves <br />- post a sign conspicuously stating that it is a permanently closed container and denoting the date of closure. <br />Immediately "Permanently Close" all tanks that are not being used or amend the Spill Prevention, Control, and <br />Countermeasure Plan to include all petroleum tanks that have not been permanently closed. <br />This is a minor violation. <br />Overall Inspection Comments: <br />Routine closure inspection today. Defense Logistics Agency (DLA) ceased operations at this location <br />approximately September 2014. <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by July 25,2015 . <br />Once the Return to Compliance Certification is received along with a corrective action statement and supporting <br />documentation the facility's aboveground petroleum storage facility permit will be inactivated with the SJC EHD. <br />Received by <br />Inspector:/ <br />Phone: <br />Date: <br />(initial): <br />MICHELLE HENRY, Lead Senior RE <br />(209) 468-3454 <br />06/24/2015 <br />Page 3 oflqi�/ <br />