My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SIKORSKY
>
5000
>
2800 - Aboveground Petroleum Storage Program
>
PR0541901
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/26/2018 4:31:54 PM
Creation date
8/24/2018 7:22:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0541901
PE
2832
FACILITY_ID
FA0016555
FACILITY_NAME
ATLANTIC AVIATION
STREET_NUMBER
5000
STREET_NAME
SIKORSKY
STREET_TYPE
St
City
STOCKTON
Zip
95206
APN
17726034
CURRENT_STATUS
01
SITE_LOCATION
5000 Sikorsky St
P_DISTRICT
001
QC Status
Approved
Scanner
EJimenez
Supplemental fields
FilePath
\MIGRATIONS\S\SIKORSKY\5000\PR0541901\COMPLIANCE INFO 2018 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2018 - PRESENT
QuestysRecordDate
8/8/2018 10:56:25 PM
QuestysRecordID
3959462
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
` , UEnvironmental Health Department <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ATLANTIC AVIATION 5000 Sikorsky St, STOCKTON August 07, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 711 CFR 112.8(c)(6)Failed to perform scheduled tank tests or inspections by appropriately qualified personnel. <br /> Current inspections on the tanks are not being performed per industry standard SP001, as stated on the SPCC <br /> plan. Each aboveground container shall be tested and inspected for integrity on a regular schedule and whenever <br /> repairs are made. The qualifications of personnel performing tests and inspections,frequency and type of testing <br /> and inspections that take into account container size, configuration, and design shall be determined in accordance <br /> with industry standards. Examples of these integrity tests include, but are not limited to:visual inspection, <br /> hydrostatic testing, radiographic testing, ultrasonic testing, acoustic emissions testing, or other systems of <br /> non-destructive testing. Comparison records and other records of inspections and tests must be maintained on site. <br /> Immediately conduct the necessary testing and submit a copy of the test results to the EHD, or provide equivalence <br /> as allowed by CFR 112.7(a)(2). <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork by September 6, 2018. <br /> Note: A mobile refueler was observed near the "fuel facility"and was said to be out of service. The mobile <br /> refueler was said to be storing petroleum fuel for the last month and a half. <br /> Please be aware as of January 1, 2013, all businesses are required to submit all new(or any changes to <br /> existing)Aboveground Petroleum Storage Act (APSA) information online to the California Environmental <br /> Reporting System (CERS)at http://cers.calepa.ca.gov in addition to any other relevant activities and required <br /> fields. No later than January 1, 2014, all APSA data must be entered and or updated in CERS. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: August 07, 2018 Inspector: Inspector Phone: <br /> Printed Name and Title: CESAR RUVALCABA, REHS (209)953-6213 <br /> Geoffrey Cochran, Line Service Manager <br /> FA0016555 PR0541901 SCO01 08/07/2018 <br /> EHD 28-01 Rev.11/07/2017 Page 5 of 5 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.