Laserfiche WebLink
Monitoring System Certification <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurlsdictions Within the State of California <br /> Authority Cited., Chapter 6.7, Health and Safety Code;Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or ret)ort must be prepared for each <br /> monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. <br /> The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: RAMOS OIL Bldg.No.: <br /> Site Address: 8925 W. WORNTON ROAD City: THORNTON Zip: 95686 <br /> Facility Contact Person: DAVE NELSON Contact Phone No.: (916)371-3289 <br /> Make/Model of Monitoring System: VEEDER-ROOT TLS-350 Date of Testing/Servicing: 3/29/2012 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the a ro riate boxes to indicatespecific a ui ment inspected/serviced.— <br /> Tank <br /> ns ected/serviced:Tank ID: Tank ID: <br /> ❑In-Tank Gauging Probe. Model: ❑In-Tank Gauging Probe. Model: <br /> ❑Annular Space or Vault Sensor. Model: ❑Annular Space or Vault Sensor. Model: <br /> ❑Piping Sump/Trench Sensor(s). Model: ❑Piping Sump/Trench Sensor(s). Model: <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> Tank Overfill/Hi -Level Sensor. Model: <br /> El Tank Overfill/High-Level Sensor. Model: E] �' <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> TanklD: Tank ID: <br /> ❑In-Tank Gauging Probe. Model: ❑In-Tank Gauging Probe. Model: <br /> ❑Annular Space or Vault Sensor. Model: ❑Annular Space or Vault Sensor. Model: <br /> ❑Piping Sump/Trench Sensor(s). Model: ❑Piping Sump/Trench Sensor(s). Model: <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: <br /> El Tank Overfill/High-Level Sensor. Model: ❑ � <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 8A Dispenser ID: 9 <br /> ®Dispenser Containment Sensor(s). Model: 208 ®Dispenser Containment Sensor(s). Model: 208 <br /> M Shear Valve(s). ®Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 9A Dispenser ID: 10 <br /> ®Dispenser Containment Sensor(s). Model: 208 ®Dispenser Containment Sensor(s). Model: 208 <br /> ®Shear Valve(s). ®Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 10A Dispenser ID: <br /> ®Dispenser Containment Sensor(s). Model: 208 ❑Dispenser Containment Sensor(s). Model: <br /> ®Shear Valve(s). ❑Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification -I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br /> correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also <br /> attached a copy of the report;(check all that apply): ® System set-up ® Alarm history report <br /> Technician Name(print): RICHARD THOMAS Signature: t a u -5 <br /> Certification No.: B34022 License.No.: 803705 <br /> Testing Company Name: TANK-TEK ENVIRONMENTAL CORPORATION Phone No.:(707)446-6151 <br /> Testing Company Address: 607 ELMIRA ROAD, PMB 336, VACAVILLE, CA 95687 Date of Testing/Servicing: 3/29/2012 <br /> t)N-036— www.unidoo.org Rev.01/17/08 <br />