My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
30350
>
2800 - Aboveground Petroleum Storage Program
>
PR0527885
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/19/2019 10:30:05 AM
Creation date
8/24/2018 7:32:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0527885
PE
2832
FACILITY_ID
FA0009761
FACILITY_NAME
CEMEX CONST MATERIALS PACIFIC LLC
STREET_NUMBER
30350
Direction
S
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95377
APN
25313011
CURRENT_STATUS
01
SITE_LOCATION
30350 S TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\T\TRACY\30350\PR0527885\COMPLIANCE INFO PRE 2016.PDF
QuestysFileName
COMPLIANCE INFO PRE 2016
QuestysRecordDate
9/14/2016 10:21:15 PM
QuestysRecordID
3193082
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> ABOVEGROUND PETROLEUM STORAGE ACT (APSA) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Fatality Cemex Construction/Read Mix Facility 30350 South Tracy Blvd, Tracy Daeection <br /> Name )/ Address: May 17, 2013 <br /> : <br /> VIOLATIONS <br /> # Ct C2 M I Code Section HSC=CA Health and Safety Code,CFR=Code of Federal Regulations <br /> Cl =Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> NIIIIIIIIIIIL eri for`Ori'shore Facilities(excluding- induction facilities o <br /> 605 3 CFR 112.8(b)(5) Failed to provide two"lift'pumps, one permanently installed,where drainage waters are continuously <br /> treated in more than one treatment unit,or provide equivalence as allowed by CFR 112.7(a)(2) <br /> 606 CFR 112.8(c)(1) Container not compatible with oil stored and/or storage conditions, or failed to provide equivalence as <br /> allowed by CFR 112.7(a)(2) <br /> Failed to provide sufficient secondary containment capacity for a bulk storage tank that would hold the <br /> 607 CFR 112.8(c)(2) volume of the largest container plus sufficient freeboard to contain precipitation and/or diked area is not <br /> sufficiently impervious to contain discharged oil <br /> Allowed drainage of uncontaminated rainwater from a diked area and failed to:(i)keep bypass valves <br /> 608 CFR 112.8(c)(3) sealed closed;(ii)inspect retained rainwater prior to discharge;(iii)open bypass valve and reseal it <br /> under responsible supervision;(iv)maintain adequate records of such events;or provide equivalence <br /> as allowed by CFR 11 2.7 a 2 <br /> Failed to:test each aboveground container for integrity on a regular schedule or when repairs were <br /> 609 CFR 112.8(c)(6) made;inspect containers and container supports;or keep records of inspections and tests,or provide <br /> equivalence as allowed by CFR 112.7(a)(2) <br /> 610 CFR 112.8(c)(7) Failed to provide effective leakage control through defective internal heating coils,or provide <br /> equivalence as allowed by CFR 112.7(a)(2) <br /> 611 CFR 112.8(c)(8) Failed to install and regularly test approved liquid level sensing devices,or provide equivalence as <br /> allowed by CFR 112.7(a)(2) <br /> 612 CFR 112.8(c)(9) Failed to observe effluent treatment facility frequently enough to detect system upsets that could cause <br /> a discharge,or provide equivalence as allowed by CFR 112.7(a)(2) <br /> 613 CFR 112.8(c)(10) Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas,or <br /> rovide equivalence as allowed b CFR 112.7 a 2 <br /> Failed to locate portable containers to prevent discharge or provide sufficient secondary containment <br /> 614 CFR 112.8(c)(11) capacity that will hold the volume of the largest container plus sufficient freeboard to contain <br /> precipitation <br /> Failed to provide buried piping with a protective wrapping and coating and cathodic protection and/or <br /> 615 CFR 112.8(d)(1) inspect buried piping for corrosion damage when exposed,or provide equivalence as allowed by CFR <br /> 112.7(a)(2) <br /> Failed to cap or blank-Flange terminal connection at transfer point and mark its origin when piping is not <br /> 616 CFR 112.8(d)(2) in service or in standby service for an extended time,or provide equivalence as allowed by CFR <br /> 112,7(a)(2) <br /> 617 CFR 112.8(d)(3) Failed to design pipe supports to minimize abrasion and corrosion and to allow for expansion and <br /> contraction,or provide equivalence as allowed by CFR 11 2.7 a 2 <br /> 618 CFR 112.8(d)(4) Failed to regularly inspect aboveground valves,piping,and appurtenances,or provide equivalence as <br /> allowed b CFR 112.7(a)(2) <br /> 619 CFR 112.8(d)(4) Failed to conduct integrity and leak test for buried piping at time of installation,modification, <br /> construction,relocation,or replacement,or provide equivalence as allowed by CFR 112.7(a)(2 <br /> 620 CFR 112.8(d)(5) Failed to provide adequate warnings to vehicles entering facility to protect aboveground piping and <br /> other oil transfer operations,or provide equivalence as allowed by CFR 112.7 a 2 <br /> 999 Other: See attached"Continuation-Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Routine SPCC /APSA inspection <br /> Minor/ Notice to Comply violation: 510,&46- <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE <br /> Inspector Rec Tills: <br /> EH028-02 Rev04119112 V Page APSA INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.