Laserfiche WebLink
SAN JOAQUIN COUNTY �..i <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax.(209)468-3433 Web:www.sigov.org/ehd/unitiii.htmi <br /> ABOVEGROUND PETROLEUM STORAGE ACT (APSA) PROGRAM INSPECTION REPORT <br /> Facility _ Inspectio <br /> Name: Fac'itys: ( ftgii Date: <br /> Facility Title: r Phn <br /> Type: <br /> Contact: Anfla <br /> Inspection Routine 1_I Fallow up C complaint—ID#: Other: <br /> (Authority HC 25270.4) <br /> Consent for. " Inspection ampling')(Photos Granted by: Title: <br /> AST /fPf.{, Total Facility Shell <br /> Content UV Q� Capacity(gal): <br /> ._._._._. ._._._._. -_ ._ _._._-_-_. -_-_._-_. ._._-_._ ----------------- -- ._._._._._ <br /> SPCC <br /> lan <br /> 11 <br /> Capaclity (� �'0 1!N �� ReviewPDate:year YV j 10 <br /> SPCC Plan type: C APSA SPCC conditionally exempt(HSC 25270.4.5(b)) Yully or partially Professional Engineer certified Self-certified <br /> VIOLATIONS <br /> # Cl I C2 M Code Section HSC=California Health and Safety Code;CCR=California Code of Regulations <br /> C1 =Class 1 violation',C2=Class 2 violation;M=Minor violation <br /> Aboveground Petroleum Storage Act <br /> g102 <br /> HSC 25270.4.5(a) Failed to prepare a written SPCC Plan in accordance with CFR Part 112 <br /> HSC 25270.4.5(a) Failed to conduct periodic inspections of the stora a tank to assure compliance with CFR Part 112 <br /> HSC 25270.6(a) Failed to file business plan or annual tank facility statement if capacity>10K gallons and>-5% <br /> etroleum <br /> HSC 25270.6(b) Failed to submit APSA fees <br /> HSC 25270.8 Failed to report spills or releases of 42 gallons or more <br /> Requirement to Prepare and Implement a SPCC Plan <br /> 201 CFR 112.3(d) SPCC Plan certification by a Professional Engineer(PE) missing or incomplete <br /> 202 CFR 1123(e) Failed to retain a copy of the SPCC Plan on site <br /> Amendment of SPCC Plan by owners or operators <br /> 301CFR 112.5(a) Failed to amend SPCC Plan within 6 months,or implement changes within 6 months of amendment <br /> when there is an ap licable change to the facility <br /> 302 CFR 112.5(b) Failed to amend SPCC Plan within 6 months,or implement changes within 6 months of amendment <br /> after scheduled 5 year Plan review <br /> 303 CFR 112.5(b) Failed to complete a review and evaluation of SPCC plan at least once every 5 years <br /> 304 JCFR 112.5(c) Failed to have a PE certify technical amendments within 6 months of than e <br /> Qualified Facilities Plan Requirements <br /> 401 CFR 112.6(a) Tier I qualified facility failed to self-certify(1)SPCC Plan; (2)technical amendment when there was an <br /> applicable change to the SPCC Plan <br /> 402 CFR 112.6(a)(3) Tier I qualified facility SPCC Plan incomplete <br /> 403 CFR 112.6(b) Tier II qualified facility failed to self-certify(1)SPCC Plan; (2)technical amendment when there was an <br /> applicable change to the SPCC Plan <br /> 404 CFR 112.6(b)(4) Failed to provide written PE certification in a self-certified plan for alternate methods which provide <br /> environmental equivalence, or provisions in lieu of secondary containment due to impracticality <br /> General Requirements for SPCC Plans <br /> 501 CFR 112.7 Failed to include a cross-referencing section for a Plan that does not follow the sequence specified in this <br /> section <br /> 502 CFR 112.7 SPCC Plan lacks full approval of management at a level of authority to commit the necessary resources <br /> to implement the Plan <br /> 503 CFR 112.7(a)(2) Failed to provide equivalent environmental protection and/or state the reasons for nonconformance and <br /> describe the alternate methods and how they achieve equivalent environmental protection <br /> 504 CFR 112.7(a)(3) No facility diagram or diagram failed to show location and contents of each container,transfer stations, <br /> and connecting pipes. <br /> 505 CFR 112.7 a 3 i SPCC Plan failed to include description of product type and storage capacity for each container <br /> 506 CFR 112.7(a)(3)(ii) SPCC Plan failed to include procedures for routine handling of products and discharge prevention <br /> measures <br /> 507 CFR 112.7(a)(3)(iii) SPCC Plan failed to show discharge or drainage controls(secondary containment), equipment,and <br /> procedures for the control of a discharge <br /> 508 CFR 112.7(a)(3)(iv) SPCC Plan failed to show countermeasures for discovery, response and cleanup of discharges <br /> Iinsp Ai Received By: Title: <br /> EHD 28-02 Rev 9/1/11 U Page 1 APSA INSPECTION REPORT <br />