Laserfiche WebLink
Environmental Health Department <br />Aboveground Petroleum Storage Act Inspection Report <br />Facility Name: <br />VALLEY ROCK QUARRY <br />Facility Address: <br />37350 S BIRD RD, TRACY <br />Date: <br />July 12, 2018 <br />SUMMARY OF VIOLATIONS <br />(CLASS 1, CLASS 11, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />618 <br />CFR 112.7(e), 112.8(c)(6) Failed to keep records of procedures, inspections, or integrity tests for three years. <br />Copies of inspection and testing records were not found on site. Inspections and tests must be conducted in <br />accordance with the written procedures developed in the Spill Prevention, Control, and Countermeasure (SPCC) <br />Plan, Records of these inspections and tests must be signed by the appropriate supervisor or inspector and kept on <br />site with the SPCC Plan for a period of three years. Immediately locate a copy of all inspection and testing records <br />for the last three years, maintain them on site, and submit copies to the EHD. <br />This is a Class 11 violation, <br />624 <br />CFR 112.7(g) Facility failed to implement security of site and valves, lock out/tag out, and lighting. <br />The Spill Prevention, Control, and Countermeasure include discussion of lighting in the area but the facility does not <br />have elctricity, The SPCC Plan must include descriptions of how you secure and control access to the oil handling, <br />processing & storage areas, secure master flow & drain valves, prevent unauthorized access to starter controls on <br />oil pumps, secure out -of -service and loading/unloading connections of oil pipelines, and address the <br />appropriateness of security lighting to both prevent acts of vandalism and assist in the discovery of oil discharges. <br />Immediately update the SPCC Plan to include all of the required Security information, or provide equivalence as <br />allowed by 40 CFR 112.7(a)(2), <br />This is a Class 11 violation. <br />706 <br />CFR 112.8(c)(2) Failed to provide and maintain adequate secondary containment. <br />The 10,000 gallon diesel tank and the 550 used oil tank were observed with insufficient secondary containment. <br />The SPCC plan calls for removal of soil in the sump beneath the 10,000 gallon diesel AST and for small cracks to <br />be epoxied. Soil was observed in the sump under the 10,000 gallon AST and epoxy was not seen on small cracks in <br />the secondary containment walls and floor. All bulk storage tanks must be provided with a secondary means of <br />containment for the entire capacity of the tank and sufficient freeboard to contain precipitation. Immediately provide <br />sufficient secondary containment for this and all other tanks at this facility. <br />This is a Class 11 violation, <br />714 <br />CFR 11 2.8(c)(8)(i-iv) Failed to provide each container with a high level monitoring device. <br />The 10,000 gallon diesel and the 550 gallon used oil ASTs were not observed with a high level monitoring device <br />and this was not addressed in the SPCC plan. At least one of the following devices must be installed in each <br />container: <br />- High liquid level alarm with audible or visual signal <br />- High liquid level pump cutoff device set to stop flow at a predetermined content level <br />- Direct audible or code signal communication between the container gauger and the pumping station <br />- Fast response system, such as digital computer, telepulse, or direct vision gauge. If a direct vision gauge is <br />being used for determining the liquid level of each tank, a person must be present to monitor gauges and the overall <br />filling of the tanks. <br />Immediately install an approved liquid level sensing device in accordance with CFR 112,8 and implement necessary <br />procedures to ensure that the devices are fully functional and in use at all times during tank filling operations, or <br />provide equivalence as allowed by CFR 112,7(a)(2), <br />This is a Class 11 violation. <br />FA0011282 PR0539897 SCO01 07/12/2018 <br />EHD 28-01 Rev, 11/07/2017 Page 5 of 6 Aboveground Petroleum Storage Act OR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />