My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BROADWAY
>
1640
>
2800 - Aboveground Petroleum Storage Program
>
PR0541223
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/11/2019 9:05:12 PM
Creation date
8/24/2018 7:42:49 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0541223
PE
2832
FACILITY_ID
FA0014999
FACILITY_NAME
Global Materials Management, LLC
STREET_NUMBER
1640
Direction
N
STREET_NAME
BROADWAY
STREET_TYPE
Ave
City
Stockton
Zip
95205
CURRENT_STATUS
02
SITE_LOCATION
1640 N Broadway Ave
QC Status
Approved
Scanner
FRuiz
Supplemental fields
FilePath
\MIGRATIONS\B\BROADWAY\1640\PR0541223\COMPLIANCE INFO 2016 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
6/14/2018 3:41:59 PM
QuestysRecordID
3915887
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:( 09) 468-3420 Fax:(209) 468-3433 Web:www.sigov.orq/ehd/unitiii.html <br /> ABOVEGROUND PETROLEUM STORAGE ACT(APSA) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Facility Facility ,�n� , Inspection Q /� <br /> Name: Address: /G� /TVA Date: v <br /> VIOLATIONS <br /> # C1 C2 M Code Section HSC=CA Health and Safety Code;CFR=Code of Federal Regulations <br /> C1 =Class 1 violation,C2=Class 2 violation;M=Minor violation <br /> SPCC Plan Requirements for Onshore Facilities(excluding production facilities)(continued) <br /> 605 CFR 112.8(b)(5) Failed to provide two"lift'pumps,one permanently installed,where drainage waters are continuously <br /> treated in more than one treatment unit,or provide equivalence as allowed by CFR 11 2.7 a 2 <br /> 606 CFR 112.8(c)(1) Container not compatible with oil stored and/or storage conditions,or failed to provide equivalence as <br /> allowed by CFR 112.7(a)(2) <br /> Failed to provide sufficient secondary containment capacity for a bulk storage tank that would hold the <br /> 607 CFR 112.8(c)(2) volume of the largest container plus sufficient freeboard to contain precipitation and/or diked area is not <br /> sufficiently impervious to contain discharged oil <br /> Allowed drainage of uncontaminated rainwater from a diked area and failed to: (i) keep bypass valves <br /> 608 CFR 112.8(c)(3) sealed closed;(ii)inspect retained rainwater prior to discharge; (iii)open bypass valve and reseal it <br /> under responsible supervision; (iv)maintain adequate records of such events;or provide equivalence <br /> as allowed by CFR 11 2.7 a 2 <br /> Failed to:test each aboveground container for integrity on a regular schedule or when repairs were <br /> 609 CFR 112.8(c)(6) made; inspect containers and container supports;or keep records of inspections and tests,or provide <br /> equivalence as allowed by CFR 11 2.7 a 2 <br /> 610 CFR 112.8(c)(7) Failed to provide effective leakage control through defective internal heating coils, or provide <br /> equivalence as allowed by CFR 112.7(a)(2) <br /> 611 CFR 112.8(c)(8) Failed to install and regularly test approved liquid level sensing devices,or provide equivalence as <br /> allowed by CFR 11 2.7 a 2 <br /> 612 CFR 112.8(c)(9) Failed to observe effluent treatment facility frequently enough to detect system upsets that could cause <br /> a discharge,or provide equivalence as allowed by CFR 112.7(a)(2) <br /> 613 X CFR 112.8(c)(10) Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas,or <br /> provide a uivalence as allowed by CFR 11 2.7 a 2 <br /> Failed to locate portable containers to prevent discharge or provide sufficient secondary containment <br /> 614 CFR 11 2.8(c)(11) capacity that will hold the volume of the largest container plus sufficient freeboard to contain <br /> reci itation <br /> Failed to provide buried piping with a protective wrapping and coating and cathodic protection and/or <br /> 615 CFR 112.8(d)(1) inspect buried piping for corrosion damage when exposed,or provide equivalence as allowed by CFR <br /> 112.7(a)(2) <br /> Failed to cap or blank-flange terminal connection at transfer point and mark its origin when piping is not <br /> 616 CFR 112.8(d)(2) in service or in standby service for an extended time,or provide equivalence as allowed by CFR <br /> 112.7(a)(2) <br /> 617 CFR 112.8(d)(3) Failed to design pipe supports to minimize abrasion and corrosion and to allow for expansion and <br /> contraction,orprovide equivalence as allowed by CFR 112.7(a)(2) <br /> 618 1 CFR 112.8(d)(4) Failed to regularly inspect aboveground valves,piping,and appurtenances,or provide equivalence as <br /> allowed by CFR 112.7(a)(2) <br /> 619 CFR 112.8(d)(4) Failed to conduct integrity and leak test for buried piping at time of installation,modification, <br /> construction, relocation,or replacement,or provide equivalence as allowed by CFR 112.7(a)(2) <br /> 620 CFR 112.8(d)(5) Failed to provide adequate warnings to vehicles entering facility to protect aboveground piping and <br /> other oil transfer operations,or provide equivalence as allowed by CFR 11 2.7 a 2 <br /> Other Violations <br /> 999 Other: See attached "Continuation-Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I, CLASS II, or MINOR-Notice to Comply) <br /> ALL EHD STAFF TIME ASSOCIATE WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE <br /> Inspector: Received By: Title: <br /> t. L� 4Pt" t �, <br /> EHD 28- Re /1/11 Page 3 APSA INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.