FUEL SYSTEMS CAT <br /> FCUL2 - UL LISTED <br /> FUEL TANKS <br /> CLOSED TOP DIKED SKID BASE <br /> FUEL TANK <br /> The generator set skid base contains an integral, <br /> UL listed,double walled,steel fuel storage tank <br /> with diked rupture basin for the containment of fuel <br /> resulting from a tank leak or rupture.The rupture <br /> basin is integrally vented and has a closed top to <br /> prevent the ingress of precipitation, debris or <br /> other elements.The tank is leak tested to 3 psi <br /> and pressure tested to 15 psi.The base tank is <br /> UL142 listed for Steel Above Ground Tanks for <br /> Flammable and Combustible Liquids under the <br /> "Special Purpose Tanks" category.They are <br /> Image shown may not reflect actual package intended for installation in accordance with <br /> the Flammable and Combustible Liquids <br /> Code, NFPA 30 of the National Fire <br /> Protection Association. <br /> FCUL2—Fuel capacity to provide typically 24 hour <br /> standby operation.See tables for actual fuel tank <br /> capacity and running hours. <br /> FEATURES <br /> CONSTRUCTION <br /> • Manufactured entirely from 8 gauge(4 mm)steel • Primary vent with breather <br /> • Continuously welded seams • Vent located accessible for adapting to <br /> • Formed steel channel type side beams remote venting <br /> • Unitized load bearing structure • Venting areas to UL142 specifications <br /> • Integral lifting points • Leak detection switch <br /> • Corrosion resistant precoat • Emergency vent for main tank <br /> • Listed to UL142 • Weatherproof diked containment basin <br /> • Closed top diked base tank,capacity 110% • Removable base-end cover plate encloses <br /> • Continuous high gloss finish stub-up area when used with enclosures <br /> • Polyester powder composite • Seismic Certification per applicable building codes: <br /> IBC 2000,IBC 2003, IBC 2006, IBC 2009,CBC 2007 <br /> • Extremely durable and corrosion resistant • Tested and analyzed in accordance with: I <br /> • Unique integral base and tank design <br /> ASBE 7-98,ASBE 7-02,ASCE 7-05,ICC-ES AC-156 <br /> • Developed specifically for open or enclosed • Anchoring details are site specific,and are <br /> generator sets dependent on many factors such as generator <br /> • Internal baffles arranged to prevent set size,weight,and concrete strength. <br /> recirculation of heated return fuel IBC Certification requires that the anchoring <br /> • Brass composite 2"filler cap system used is reviewed and approved by <br /> • Mechanical fuel gauge a Professional Engineer. <br />