FA0003761
FACILITY_NAME
ST JOSEPHS HOSPITAL
STREET_NUMBER
1800
Direction
N
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12718044
CURRENT_STATUS
01
SITE_LOCATION
1800 N CALIFORNIA ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
EJimenez
Supplemental fields
FilePath
\MIGRATIONS\C\CALIFORNIA\1800\PR0528692\COMPLIANCE INFO .PDF
QuestysFileName
COMPLIANCE INFO
QuestysRecordDate
4/28/2016 4:15:48 PM
QuestysRecordID
3023440
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJ O 1` Q U I `IA,II, Environmental Health Department <br /> COUNTY <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ST JOSEPHS HOSPITAL 1800 N CALIFORNIA ST, STOCKTON December 12, 2018 <br /> Other Violations <br /> 4030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 4040 See below Unlisted Release/Leaks/Spills violation ❑V ❑R ❑COS <br /> 4050 See below Unlisted Abandonment/Illegal Disposal/Unauthorized Treatment violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 203 CFR 112.3 Failure to implement the SPCC Plan. <br /> The SPCC plan states that"Table 7"of the SPCC plan would be posted next to unloading and transfer areas, <br /> "Table 7"was not observed to be posted next to unloading and transfer areas and could not be pointed out by <br /> facility personnel. The owner or operator or an onshore or offshore facility subject to this section must prepare in <br /> writing and implement a Spill Prevention Control and Countermeasure Plan (hereafter"SPCC Plan"or"Plan")," in <br /> accordance with§ 112.7 and any other applicable section of this part. Immediately implement the SPCC plan as <br /> written or amend the SPCC Plan to accurately represent the procedures and policies currently in place at the facility. <br /> This is a Class II violation. <br /> 301 CFR 112.5(a) Failed to amend Plan as necessary. <br /> Two day tanks described as having a capacity of 250 gallons where not addressed in the SPCC plan.The oil <br /> storage capacity for the two Caterpillar branded generators with engine model 3512 may have a capacity of over 55 <br /> gallons of oil storage and were not addressed in the operational equipment section of the SPCC plan. The Spill <br /> Prevention, Control, and Countermeasure(SPCC) Plan must be amended when there is a change in the facility <br /> design, construction, operation,or maintenance that materially affects its potential for a discharge,within 6 months <br /> of the change, and implemented as soon as possible, not later than 6 months following preparation of the <br /> amendment. Immediately make all necessary amendments to the SPCC Plan to accurately represent the <br /> procedures and policies currently in place at the facility. <br /> This is a Class II violation. <br /> 302 CFR 112.5(b) Failed to review Plan once every five years and/or implement any resulting amendments. <br /> The Spill Prevention, Control, and Countermeasure(SPCC)Plan was last reviewed on June 22, 2012. The SPCC <br /> plan calls for a 5 year review by September 2017, and a review has not been conducted. A review and evaluation of <br /> the SPCC Plan must be conducted at least once every 5 years. As a result of this review and evaluation,the SPCC <br /> Plan must be amended within 6 months of review, and recertified by a Professional Engineer if any technical <br /> amendments were made. Immediately conduct a review of the facility SPCC Plan and make any necessary <br /> amendments. <br /> This is a Class II violation. <br /> FA0003761 PR0528692 SCO01 12/12/2018 <br /> EHD 28-01 Rev.09/27/2018 Page 4 of 6 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.