My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CARPENTER
>
4863
>
2800 - Aboveground Petroleum Storage Program
>
PR0538368
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2019 2:51:33 PM
Creation date
8/24/2018 7:45:46 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0538368
PE
2831
FACILITY_ID
FA0005712
FACILITY_NAME
SGS Stockton - Carpenter Road
STREET_NUMBER
4863
STREET_NAME
CARPENTER
STREET_TYPE
RD
City
Stockton
Zip
95215
APN
17905010
CURRENT_STATUS
01
SITE_LOCATION
4863 CARPENTER RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\C\CARPENTER\4863\PR0538368\COMPLIANCE INFO 2016-PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2016-PRESENT
QuestysRecordDate
3/2/2016 6:40:42 PM
QuestysRecordID
3020961
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
82
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue , Stockton , California 95205 -6232 <br /> Telephone: (209) 468-3420 Fax : (209) 468-3433 Web: www. sjgov. org/ehd <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SGS Stockton - Carpenter Road Stockton February 26 2016 <br /> General Requirements for SPCC Plans <br /> 615 CFR 112 . 7(0 (2) Failed to designate a person accountable for discharge prevention ❑ V ❑ R ❑ COS <br /> 616 CFR 112 . 7(%3) Failed to schedule and conduct discharge prevention briefings at least annually ■ V ❑ R ❑ COS <br /> 617 CFR 112 . 7(g) Plan failed to address security of site and valves , lock out/tag out , and lighting ❑ V ❑ R ❑ COS <br /> 618 CFR 112 . 7(h) ( 1 ) Loading/unloading rack containment system not properly sized ❑ V ❑ R ❑ COS <br /> 619 CFR 112 . 7(h) (2) Failed to provide vehicular departure system loading and unloading racks ❑ V ❑ R ❑ COS <br /> 620 CFR 112 . 7(h) (3) Failed to inspect lowermost drains and outlets prior to filling and departure of vehicles ❑ V ❑ R ❑ COS <br /> 621 CFR 112 . 7(1) Failed to evaluate field constructed container for brittle fracture and take appropriate action ❑ V ❑ R ❑ COS <br /> 622 CFR 112 . 70) Failed to include discussion of conformance to discharge prevention and containment procedures ❑ V ❑ R ❑ COS <br /> SPCC Plan Requirements for Onshore Facilities (excluding production facilities) <br /> 701 CFR 112 . 8(b) (2) Failed to use manual open-and-closed design valves for the drainage of diked areas ❑ V ❑ R ❑ COS <br /> 702 CFR 112. 8(b)(3) , Failed to design facility drainage system from undiked areas to retain in the facility ❑ V ❑ R ❑ COS <br /> 112 . 8(b)(4) <br /> 703 CFR 112 . 8(b) (5) Failed to provide two lift pumps for more than one continuous treatment unit ❑ V ❑ R ❑ COS <br /> 704 CFR 112 . 8(c) (2) Diked area is not sufficiently impervious to contain discharged oil ❑ V ❑ R ❑ COS <br /> 705 CFR 112 . 8 (c)( 1 ) Container not compatible with oil stored and/or storage conditions ❑ V ❑ R ❑ COS <br /> 706 CFR 112 . 8(c)(2) Failed to provide and maintain adequate secondary containment ❑ V ❑ R ❑ COS <br /> 707 CFR 112 . 8(c) (3) (i) Failed to keep containment bypass valves closed when not draining rainwater ❑ V ❑ R ❑ COS <br /> 708 CFR 112 . 8(c) (3) (ii) Failed to inspect retained rainwater prior to discharge ❑ V ❑ R ❑ COS <br /> 709 CFR 112 . 8(c) (3) (iii) Failed to open and close bypass valve to drain rainwater under responsible supervision ❑ V ❑ R ❑ COS <br /> 710 CFR 112 . 8(c) (3) (iv) Failed to maintain records of drainage from diked areas ❑ V ❑ R ❑ COS <br /> 711 CFR 112 . 8(c) (5) Failed to provide corrosion protection for partially buried tanks ❑ V ❑ R ❑ COS <br /> 712 CFR 112 . 8(c) (6) Failed to perform tank inspections that take into account size , configuration , and design ❑ V ❑ R ❑ COS <br /> 713 CFR 112 . 8(c) (6) Failed to perform scheduled tank tests and inspections by appropriately qualified personnel ■ V ❑ R ❑ COS <br /> 714 CFR 112 . 8 (c) (6) Failed to test and inspect containers by appropriately qualified personnel after material repairs ❑ V ❑ R ❑ COS <br /> 715 CFR 112 , 8 (c) (7) Failed to provide effective leakage control through defective internal heating coils ❑ V ❑ R ❑ COS <br /> 716 CFR 112 . 8(c)(8) (i-iv) Failed to provide each container with a high level monitoring device ■ V ❑ R ❑ COS <br /> 717 CFR 112 . 8(c)(8) (v) Failed to regularly test liquid level sensing devices to ensure proper operation ❑ V ❑ R ❑ COS <br /> 718 CFR 112 . 8 (c) (9) Failed to observe effluent treatment frequently enough to detect potential discharge ❑ V ❑ R ❑ COS <br /> 719 CFR 112 . 8(c) ( 10) Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas ❑ V ❑ R ❑ COS <br /> 720 CFR 112 . 8(c) ( 11 ) Failed to provide sufficient secondary containment capacity for mobile or portable containers ❑ V ❑ R ❑ COS <br /> 721 CFR 112 . 8(c)(11 ) Failed to locate mobile or portable containers to prevent discharge ❑ V ❑ R ❑ COS <br /> 722 CFR 112 . 8(d) ( 1 ) Failed to take corrective action on buried piping when exposed for any reason ❑ V ❑ R ❑ COS <br /> 723 CFR 112 . 8(d) ( 1 ) Failed to provide corrosion protection for buried piping ❑ V ❑ R ❑ COS <br /> 724 CFR 112 . 8 (d) (2) Failed to cap/blankAange connection at transfer point and mark its origin if not in service ❑ V ❑ R ❑ COS <br /> 725 CFR 112 . 8(d) (3) Failed to design pipe supports to minimize abrasion/corrosion and to allow for expansion/contraction ❑ V ❑ R ❑ COS <br /> Page 2 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.