My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORONADO
>
3807
>
2800 - Aboveground Petroleum Storage Program
>
PR0527630
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2019 10:21:35 AM
Creation date
8/24/2018 7:49:49 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0527630
PE
2832
FACILITY_ID
FA0003819
FACILITY_NAME
Sprint United Managemnt Co.
STREET_NUMBER
3807
STREET_NAME
CORONADO
STREET_TYPE
Ave
City
Stockton
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
3807 Coronado Ave
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
EJimenez
Supplemental fields
FilePath
\MIGRATIONS\C\CORONADO\3807\PR0527630\COMPLIANCE INFO 2008 - 2016 .PDF
QuestysFileName
COMPLIANCE INFO 2008 - 2016
QuestysRecordDate
7/26/2017 11:20:44 PM
QuestysRecordID
3532508
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJ O 1` Q U I `IA,II, Environmental Health Department <br /> COUNTY <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Sprint United Managemnt Co. 3807 Coronado Ave, Stockton July 27, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 603 CFR 112.7(a)(3)Failed to adequately describe the physical layout of the facility in the Plan. <br /> The facility diagram failed to include connected piping. The Spill Prevention, Control, and Countermeasure(SPCC) <br /> Plan shall include a facility diagram which must mark the location and contents of each fixed storage container and <br /> the storage area where mobile or portable containers are located. It must identify the location of and mark as <br /> "exempt"underground tanks. It must also include all transfer stations and connecting pipes, including intra-facility <br /> gathering lines. Immediately update the facility diagram to include all of the required information. Submit a legible <br /> copy of the updated facility diagram to the EHD for review. <br /> This is a Class II violation. <br /> 612 CFR 112.7(c) Plan failed to include secondary containment, diversionary structures, or equip to prevent discharge. <br /> The SPCC plan describes generator#1 and generator#4 as each containing a storage capacity of 61 gallons of <br /> diesel fuel.The plan classifies the generators as oil-filled operational equipment and does not address all the <br /> requirements for bulk storage tanks for the generators. If the generators store diesel,they may not be able to be <br /> listed as oil-filled operational equipment. A facility shall provide appropriate containment and/or diversionary <br /> structures or equipment to prevent a discharge. The entire containment system, including walls and floor, must be <br /> capable of containing oil and must be constructed so that any discharge from a primary containment system will not <br /> escape the containment system before cleanup occurs. Immediately provide adequate secondary containment for <br /> all aboveground petroleum storage containers larger than 55 gallons. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork by August 26, 2018. <br /> Please be aware as of January 1, 2013, all businesses are required to submit all new(or any changes to <br /> existing)Aboveground Petroleum Storage Act (APSA) information online to the California Environmental <br /> Reporting System (CERS) at http://cers.calepa.ca.gov in addition to any other relevant activities and required <br /> fields. No later than January 1, 2014, all APSA data must be entered and or updated in CERS. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by:: n Date: July 27, 2018 Inspector: Inspector Phone: <br /> 9I� � )' /� Printed Name and Title: CESAR RUVALCABA, REHS (209)953-6213 <br /> I !!!»�VVV John Denholm, EHS Engineer III <br /> FA0003819 PR0527630 SCO01 07/27/2018 <br /> EHD 28-01 Rev.11/07/2017 Page 4 of 4 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />