My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
15999
>
2800 - Aboveground Petroleum Storage Program
>
PR0528989
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/21/2019 2:14:42 PM
Creation date
8/24/2018 7:49:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0528989
PE
2832
FACILITY_ID
FA0003934
STREET_NUMBER
15999
Direction
W
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
15999 W CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\C\CORRAL HOLLOW\15999\PR0528989\COMPLIANCE INFO.PDF
QuestysFileName
COMPLIANCE INFO
QuestysRecordDate
8/30/2017 10:14:40 PM
QuestysRecordID
3614744
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
199
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN 10 A Q U I N Environmental Health Department <br /> COUNTY -- <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address : Date : <br /> Lawrence Livermore National Lab - Site 300 15999 W CORRAL HOLLOW RD , TRACY 7November 26 , 2018 <br /> Other Violations <br /> 4030 See below Unlisted Operations/Maintenance violation ❑ V ❑ R ❑ COS <br /> 4040 See below Unlisted Release/Leaks/Spills violation ❑ V ❑ R ❑ COS <br /> 4050 See below Unlisted Abandonment/] llegal Disposal/Unauthorized Treatment violation ❑ V ❑ R ❑ COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR - Notice to Comply) <br /> Item # Remarks <br /> 105 CFR 112 . 1 ( b) (3) , 112 . 2 Failure to properly close tanks when making a claim of permanently closed . <br /> A portable generator with a diesel tank of a capacity of over 55 gallons was said to be permanently closed . The <br /> generator was located in the parking area of the 875 building . The generator's diesel tank is not in use but has not <br /> been properly closed . The tank was missing a sign conspicuously stating that it is a permanently closed container <br /> and denoting the date of closure . When a tank is not in use , it must be permanently closed by meeting the following <br /> conditions : <br /> - remove all liquid and sludge from each container and connecting line <br /> - disconnect and blank off all connecting lines and piping have from the tank <br /> - close and lock all valves <br /> - post a sign conspicuously stating that it is a permanently closed container and denoting the date of closure . <br /> Immediately " Permanently Close" all tanks that are not being used or amend the Spill Prevention , Control , and <br /> Countermeasure Plan to include all petroleum tanks that have not been permanently closed . <br /> This is a minor violation . <br /> 203 CFR 112 . 3 Failure to implement the SPCC Plan . <br /> The SPCC plan calls for the replacement of the stainless-steel single-walled fuel containers on the mobile refuelers <br /> after 17 years in accordance with the STI SP-001 standards . The 100 gallon stainless-steel single-walled mobile <br /> refueler tank is over 17 years old and has not been replaced . A passing "fuel tank pressure test" dated 11 / 19/2018 <br /> was available for review for the tank identified as G7103595 . The owner or operator or an onshore or offshore <br /> facility subject to this section must prepare in writing and implement a Spill Prevention Control and Countermeasure <br /> Plan ( hereafter " SPCC Plan " or " Plan " ) , " in accordance with § 112 . 7 and any other applicable section . Implement <br /> the plan as written or submit evidence that the Fuel Tank Pressure Test meet the requirements of the SP-001 <br /> standard . <br /> This is a minor violation . <br /> 618 CFR 112 . 7 (e) , 112 . 8(c) (6) Failed to keep records of procedures , inspections , or integrity tests for three years . <br /> Copies of annual inspection records were not found on site for tanks 879TF001 , 879TF002 , 875TF003 , 875TF002 <br /> and 875TFBD04 . SPCC plan calls for monthly and annual inspections per STI SP001 standards . Inspections and <br /> tests must be conducted in accordance with the written procedures developed in the Spill Prevention , Control , and <br /> Countermeasure ( SPCC ) Plan . Records of these inspections and tests must be signed by the appropriate <br /> supervisor or inspector and kept on site with the SPCC Plan for a period of three years . Immediately locate a copy <br /> of all inspection and testing records for the last three years , maintain them on site , and submit copies to the EHD . <br /> This is a Class II violation . <br /> Overall Inspection Comments : <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> FA0003934 PR0528989 SCO01 11 /26/2018 <br /> EHD 28-01 Rev. 09/27/2018 Page 4 of 5 Aboveground Petroleum Storage Act OIR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 I F 209 464-0138 1 www. sjcehd . com <br />
The URL can be used to link to this page
Your browser does not support the video tag.