MAR 2 7 2011 San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CHEVRON STATION#307709" 1 10858 TRINITY PKWY, STOCKTON March 24 2017 <br /> UST System Observations <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status <br /> r,V o ❑COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status ❑V o R a COS <br /> 324 CCR 2717.1(g) Tampered with red tag o V u R n COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST u V c R o COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms o V ❑R ❑COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored ❑V c R u COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements ❑V ❑R o COS <br /> 329 HSC 25298 Failed to comply with permanent closure requirements c V o R ❑COS <br /> 330 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system n V ❑R ❑COS <br /> Single-Walled Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ❑V L;R ❑COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed o V ❑R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) o V ❑R o COS <br /> 404 CCR 2643(e) Biennial 0 1 gph test for gravity piping not performed(pre-January 1984) ❑V o R o COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation o V ❑R o COS <br /> 2030 See below Unlisted Operations/Maintenance violation o V o R ❑COS <br /> 2060 See below Unlisted Design/Construction violation OV o R o COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS ll,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 305 HSC 25290.1(e)VPH monitoring of the interstitial spaces of the UST system is not maintained. <br /> The S-5 91 vent line and the 91 fill sump vacuum sensor failed when tested The S-2 87 vent line and 87 fill sump float <br /> liquid sensor failed when tested The interstitial space of the UST shall be maintained, as designed,under constant <br /> vacuum such that a breach in the primary or secondary containment is detected before the hazardous substance is <br /> released into the environment The sensors were replaced and retested good during the inspection <br /> Communication of the vacuum sensors for the vent sump,tank top sumps and under dispenser containments could <br /> not be tested because the bottom ports of the UDCs and the sumps could not be opened to verify communication of <br /> vacuum monitoring throughout the interstitial space of the sumps. Make the ports accessible and notify the EHD of <br /> the test time and date Notification must be 48 hours prior to the communication testing. <br /> Communication of the vacuum sensors throughout the piping secondary containment was not tested today <br /> Communication testing of the vacuum sensor zones is required annually Schedule a test and notify the EHD of the <br /> time and date Notification must be 48 hours prior to the communication testing <br /> This is a minor violation <br /> Page 3 of 4 <br />