My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRINITY
>
10858
>
2300 - Underground Storage Tank Program
>
PR0526212
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/21/2020 9:26:53 AM
Creation date
9/4/2018 1:38:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0526212
PE
2351
FACILITY_ID
FA0017737
FACILITY_NAME
CHEVRON STATION #307709*
STREET_NUMBER
10858
STREET_NAME
TRINITY
STREET_TYPE
PKWY
City
STOCKTON
Zip
95219
APN
06602015
CURRENT_STATUS
01
SITE_LOCATION
10858 TRINITY PKWY
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
314
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for CHEVRON STATION #307709'` as of January 11, 2018. <br /> Open violations from March 24,2017 inspection <br /> Violation#305-VPH monitoring of the interstitial spaces of the UST system is not maintained. <br /> The S-5 91 vent line and the 91 fill sump vacuum sensor failed when tested. The S-2 87 vent line and 87 fill sump <br /> float liquid sensor failed when tested. The interstitial space of the UST shall be maintained, as designed, under <br /> constant vacuum such that a breach in the primary or secondary containment is detected before the hazardous <br /> substance is released into the environment. The sensors were replaced and retested good during the inspection. <br /> Communication of the vacuum sensors for the vent sump, tank top sumps and under dispenser containments could <br /> not be tested because the bottom ports of the UDCs and the sumps could not be opened to verify communication of <br /> vacuum monitoring throughout the interstitial space of the sumps. Make the ports accessible and notify the EHD of <br /> the test time and date. Notification must be 48 hours prior to the communication testing. <br /> Communication of the vacuum sensors throughout the piping secondary containment was not tested today. <br /> Communication testing of the vacuum sensor zones is required annually. Schedule a test and notify the EHD of the <br /> time and date. Notification must be 48 hours prior to the communication testing. <br /> Page 1 of 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.