BILLING_2006 - 2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRINITY
>
10858
>
2300 - Underground Storage Tank Program
>
PR0526212
>
BILLING_2006 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2023 2:51:33 PM
Creation date
9/4/2018 4:36:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING_2006 - 2008
FileName_PostFix
2006 - 2008
RECORD_ID
PR0526212
PE
2351
FACILITY_ID
FA0017737
FACILITY_NAME
CHEVRON STATION #307709*
STREET_NUMBER
10858
STREET_NAME
TRINITY
STREET_TYPE
PKWY
City
STOCKTON
Zip
95219
APN
06602015
CURRENT_STATUS
01
SITE_LOCATION
10858 TRINITY PKWY
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIFIED PROGRAM CONSOLIDATED FORM I <br />TANKS m <br />UNDERGROUND STORAGE TANKS - TANK PAGE 2 <br />Pae of <br />VL PIPING CONSTRUCTION (Check all that apply) <br />UNDERGROUND PIPING ABOVEGROUND PIPING <br />SYSTEM TYPE 'KI. PRESSURE ❑ 2. SUCTION ❑ 3. GRAVITY 458. ❑ 1. PRESSURE [12. SUCTION ❑ 3. GRAVITY 459. <br />CONSTRUCTION/ ❑ I. SINGLE WALL [13. LINED TRENCH ❑ 99. OTHER 460. ❑ 1. SINGLE WALL ❑ 95. UNKNOWN 462. <br />MANUFACTURER `SC2 DOUBLE WALL ❑ 95. UNKNOWN ❑ 2. DOUBLE WALL [199. OTHER <br />MANUFACTURER S M (-T% fj LSJ396C1►ST 461. MANUFACTURER 463. <br />❑ 1. BARE STEEL 6. FRP COMPATIBLE W/100% METHANOL ❑ 1. BARE STEEL ❑ 6. FRP COMPATIBLE W/100% METHANOL <br />❑ 2. STAINLESS STEEL ❑ 7. GALVANIZED STEEL ❑ 2. STAINLESS STEEL ❑ 7. GALVANIZED STEEL <br />[l 3. PLASTIC COMPATIBLE WITH CONTENTS ❑ 95. UNKNOWN ❑ 3. PLASTIC COMPATIBLE W/ CONTENTS [:18. FLEXIBLE (HDPE) [199. OTHER <br />FIBERGLASS ❑ 8. FLEXIBLE (HDPE) ❑ 99. OTHER [14. FIBERGLASS [:19. CATHODIC PROTECTION <br />[15. STEEL W/COATING ❑ 9. CATHODIC PROTECTION 464. ❑ 5. STEEL W/COATING ❑ 95. UNKNOWN 465. <br />VII. PIPING LEAK DETECTION (Check all that apply) (A descri tion of the monitoring program shall be submitted to the local agency.) <br />UNDERGROUND PIPING ABOVEGROUND PIPING <br />SINGLE WALL PIPING 466. SINGLE WALL PIPING 467• <br />PRESSURIZED PIPING (Check all that apply): PRESSURIZED PIPING (Check all that apply): <br />❑ <br />I. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP ❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP <br />SHUT-OFF FOR LEAK, SYSTEM FAILURE, AND SYSTEM DISCONNECTION SHUT OFF FOR LEAK, SYSTEM FAILURE, AND SYSTEM DISCONNECTION <br />+AUDIBLE AND VISUAL ALARMS. +AUDIBLE AND VISUAL ALARMS. <br />❑ 2. MONTHLY 0.2 GPH TEST ❑ 2. MONTHLY 0.2 GPH TEST <br />❑ 3. ANNUAL INTEGRITY TEST (0.1 GPH) ❑ 3. ANNUAL INTEGRITY TEST (0.1 GPH) <br />❑ 4. DAILY VISUAL CHECK <br />CONVENTIONAL SUCTION SYSTEMS CONVENTIONAL SUCTION SYSTEMS (Check all that apply) <br />❑ 5. DAILY VISUAL MONITORING OF PUMPING SYSTEM + TRIENNIAL PIPING ❑ 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br />INTEGRITY TEST (0.1 GPH) <br />SAFE SUCTION SYSTEMS (NO VALVES IN BELOW GROUND PIPING): ❑ 6. TRIENNIAL INTEGRITY TEST (0.l GPH) <br />[17. SELF MONITORING SAFE SUCTION SYSTEMS (NO VALVES IN BELOW GROUND PIPING): <br />GRAVITY FLOW [17. SELF MONITORING <br />E-19. BIENNIAL INTEGRITY TEST (0.1 GPH) GRAVITY FLOW (Check all that apply): <br />[18. DAILY VISUAL MONITORING <br />[19. BIENNIAL INTEGRITY TEST (0.1 GPH) <br />SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br />PRESSURIZED PIPING (Check all that apply): PRESSURIZED PIPING (Check all that apply): <br />10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br />ALARMS AND (Check one) ALARMS AND (Check one) <br />❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br />�b. AUTO PUMP SHUT OFF FOR LEAKS, SYSTEM FAILURE AND SYSTEM ❑ b. AUTO PUMP SHUT OFF FOR LEAKS, SYSTEM FAILURE AND SYSTEM <br />DISCONNECTION DISCONNECTION <br />❑c. NO AUTO PUMP SHUTOFF ❑c. NO AUTO PUMP SHUT OFF <br />❑ <br />11. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) WITH FLOW SHUT ❑ 11. AUTOMATIC LEAK DETECTOR <br />OFF OR RESTRICTION <br />❑ <br />12. ANNUAL INTEGRITY TEST (0.1 GPH) ❑ 12. ANNUAL INTEGRITY TEST (0.1 GPH) <br />SUCTION/GRAVITY SYSTEM SUCTION/GRAVITY SYSTEM <br />❑ 13. CONTINUOUS SUMP SENSOR + AUDIBLE AND VISUAL ALARMS [113. CONTINUOUS SUMP SENSOR + AUDIBLE AND VISUAL ALARMS <br />EMERGENCY GENERATORS ONLY (Check all that apply) EMERGENCY GENERATORS ONLY (Check all that apply) <br />[114. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF ❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF <br />AUDIBLE AND VISUAL ALARMS AUDIBLE AND VISUAL ALARMS <br />❑ 15. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) WITHOUT FLOW ❑ 15. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) <br />SHUT OFF OR RESTRICTION <br />❑ <br />16. ANNUAL INTEGRITY TEST (0.1 GPH) ❑ 16. ANNUAL INTEGRITY TEST (0.1 GPH) <br />[117. DAILY VISUAL CHECK ❑ 17. DAILY VISUAL CHECK <br />VIII. DISPENSER CONTAINMENT <br />DISPENSER CONTAINMENT 468. []1. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑ 4. DAILY VISUAL CHECK 469. <br />DATE INSTALLED []2. CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 5. TRENCH/LINER MONITORING <br />'Z3. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR ❑ 6. NONE <br />DISPENSER + AUDIBLE AND VISUAL ALARMS <br />IX. OWNER/OPERATOR SIGNATURE <br />I certify that the in ormation provided herein is true and accurate to the best of my knowledge. <br />SIGNATURE OF ERATOR DATE: 470. <br />l� OCA <br />NAME DN �PE �{, TIT�� RATOR:��#-- 472. <br />�i iC <br />Permit Number (Agency use only 473. 1 Permit Approved By (Agency use only) 474. 1 Permit Expiration Date (Agency use only) 475. <br />UPCF hwfwrc-b (1/99) - 3/4 http://www.unidocs.org Rev. 02/16/00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.