My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_2006 - 2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRINITY
>
10858
>
2300 - Underground Storage Tank Program
>
PR0526212
>
BILLING_2006 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2023 2:51:33 PM
Creation date
9/4/2018 4:36:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING_2006 - 2008
FileName_PostFix
2006 - 2008
RECORD_ID
PR0526212
PE
2351
FACILITY_ID
FA0017737
FACILITY_NAME
CHEVRON STATION #307709*
STREET_NUMBER
10858
STREET_NAME
TRINITY
STREET_TYPE
PKWY
City
STOCKTON
Zip
95219
APN
06602015
CURRENT_STATUS
01
SITE_LOCATION
10858 TRINITY PKWY
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIFIED PROGRAM CONSOLIDATED FORM l6 <br />TANKS <br />UNDERGROUND STORAGE TANKS - TANK PAGE 2 <br />Of <br />VI. PIPING CONSPRUCUIUN (Check <br />all that apply) <br />UNDERGROUND PIPING <br />ABOVEGROUND PIPING <br />SYSTEM TYPE 15(l.PR[3I. ESSURE 2. SUCTION <br />❑ 3. GRAVITY 458. <br />❑ 1. PRESSURE [12. SUCTION [13. GRAVITY <br />459. <br />CONSTRUCTION/ it I. SINGLE WALL ❑ 3. LINED TRENCH <br />[199. OTHER 460. <br />❑ I. SINGLE WALL <br />[195, UNKNOWN <br />462. <br />MANUFACTURER `jjC2 DOUBLE WALL ❑ 95. UNKNOWN <br />❑ 2. DOUBLE WALL <br />[:199. OTHER <br />MANUFACTURER SM(Ti1 fi,60RC LST 461. <br />MANUFACTURER <br />463' <br />❑ I. BARE STEEL 'A 6. FRP COMPATIBLE W/100% METHANOL <br />❑ I. BARE STEEL <br />❑ 6. FRP COMPATIBLE W/100% METHANOL <br />[12. STAINLESS STEEL [17. GALVANIZED STEEL <br />❑ 2. STAINLESS STEEL <br />❑ 7. GALVANIZED STEEL <br />[13. PLASTIC COMPATIBLE WITH CONTENTS ❑ 95. UNKNOWN <br />❑ 3. PLASTIC COMPATIBLE W/ CONTENTS <br />❑ 8. FLEXIBLE (HDPE) <br />❑ 99. OTHER <br />FIBERGLASS [18. FLEXIBLE (HDPE) ❑ 99. OTHER <br />[14. FIBERGLASS <br />❑ 9. CATHODIC PROTECTION <br />❑ 5. STEEL W/COATING ❑ 9. CATHODIC PROTECTION 464. <br />[15. STEEL W/COATING <br />[195. UNKNOWN <br />a65. <br />-innrmo nroaram shall be submitted to the local agency.) <br />SINGLE WALL PIPING 466 <br />PRESSURIZED PIPING (Check all that apply): <br />❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP <br />SHUT-OFF FOR LEAK, SYSTEM FAILURE, AND SYSTEM DISCONNECTION <br />+ AUDIBLE AND VISUAL ALARMS. <br />❑ 2. MONTHLY 0.2 GPH TEST <br />[13, ANNUAL INTEGRITY TEST (0.1 GPH) <br />CONVENTIONAL SUCTION SYSTEMS <br />❑ 5. DAILY VISUAL MONITORING OF PUMPING SYSTEM + TRIENNIAL PIPING <br />INTEGRITY TEST (0.1 GPH) <br />SAFE SUCTION SYSTEMS (NO VALVES IN BELOW GROUND PIPING): <br />❑ 7. SELF MONITORING <br />GRAVITY FLOW <br />❑ 9. BIENNIAL INTEGRITY TEST (0.1 GPH) <br />SECONDARILY CONTAINED PIPING <br />PRESSURIZED PIPING (Check all that apply): <br />10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br />ALARMS AND (Check one) <br />❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br />`�b. AUTO PUMP SHUT OFF FOR LEAKS, SYSTEM FAILURE AND SYSTEM <br />DISCONNECTION <br />❑c. NO AUTO PUMP SHUT OFF <br />❑ 11. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) WITH FLOW SHUT <br />OFF OR RESTRICTION <br />❑ 12. ANNUAL INTEGRITY TEST (0.1 GPH) <br />SUCTION/GRAVITY SYSTEM <br />❑ 13. CONTINUOUS SUMP SENSOR+ AUDIBLE AND VISUAL ALARMS <br />EMERGENCY GENERATORS ONLY (Check all that apply) <br />❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF <br />AUDIBLE AND VISUAL ALARMS <br />❑ 15. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) WITHOUT FLOW <br />SHUT OFF OR RESTRICTION <br />❑ 16. ANNUAL INTEGRITY TEST (0.1 <br />❑ 17. DAILY VISUAL CHECK <br />DISPENSER CONTAINMENT 468. <br />DATEINSTALLED <br />I certify that the infolmItijon vide( <br />SIGNATUREOFO DR <br />S <br />NAME O N PE t�}I�' <br />Pennit Number (Agency use only) 1 <br />SINGLE WALL PIPING 467. <br />PRESSURIZED PIPING (Check all that apply): <br />❑ I. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP <br />SHUT OFF FOR LEAK, SYSTEM FAILURE, AND SYSTEM DISCONNECTION <br />+ AUDIBLE AND VISUAL ALARMS. <br />❑ 2. MONTHLY 0.2 GPH TEST <br />❑ 3. ANNUAL INTEGRITY TEST (0.1 GPH) <br />❑ 4. DAILY VISUAL CHECK <br />CONVENTIONAL SUCTION SYSTEMS (Check all that apply) <br />❑ 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br />[16. TRIENNIAL INTEGRITY TEST (0.1 GPH) <br />SAFE SUCTION SYSTEMS (NO VALVES IN BELOW GROUND PIPING): <br />❑ 7. SELF MONITORING <br />GRAVITY FLOW (Check all that apply): <br />[18. DAILY VISUAL MONITORING <br />C]9. BIENNIAL INTEGRITY TEST (0.1 GPH) <br />SECONDARILY CONTAINED PIPING <br />PRESSURIZED PIPING (Check all that apply): <br />l0. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br />ALARMS AND (Check one) <br />❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br />❑ b. AUTO PUMP SHUT OFF FOR LEAKS, SYSTEM FAILURE AND SYSTEM <br />DISCONNECTION <br />❑c. NO AUTO PUMP SHUT OFF <br />❑ 11. AUTOMATIC LEAK DETECTOR <br />❑ 12. ANNUAL INTEGRITY TEST (0.1 GPH) <br />SUCTION/GRAVITY SYSTEM <br />❑ 13. CONTINUOUS SUMP SENSOR + AUDIBLE AND VISUAL ALARMS <br />EMERGENCY GENERATORS ONLY (Check all that apply) <br />❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF <br />AUDIBLE AND VISUAL ALARMS <br />❑ 15. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) <br />GPH) I [116. ANNUAL INTEGRITY TEST (0.1 GPH) <br />[117. DAILY VISUAL CHECK <br />VIII. DISPENSER CONTAINMENT <br />❑ 1. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑ <br />C12. CONTINUOUS DISPENSER PAN SENSOR+ AUDIBLE AND VISUAL ALARMS ❑ <br />V3. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR ❑ <br />DISPENSER+ AUDIBLE AND VISUAL ALARMS <br />IX, OWNER/OPERATOR SIGNATURE <br />herein is true and accurate to the best of my knowledge. <br />DATE: <br />7l l� DCS <br />I TITIN QF,Qy✓jltbR/ RATOR: t A~ <br />473. 1 Permit Approved By (Agency use only) 474. <br />UPCF hwfwrc-b (1/99) - 3/4 http://www.tinidocs.org <br />4. DAILY VISUAL CHECK 469. <br />5. TRENCH/LINER MONITORING <br />6. NONE <br />use only) 475. <br />
The URL can be used to link to this page
Your browser does not support the video tag.