My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012 - 2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRINITY
>
10858
>
2300 - Underground Storage Tank Program
>
PR0526212
>
COMPLIANCE INFO_2012 - 2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/28/2023 1:17:35 PM
Creation date
9/5/2018 2:09:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO_2012 - 2013
FileName_PostFix
2012 - 2013
RECORD_ID
PR0526212
PE
2351
FACILITY_ID
FA0017737
FACILITY_NAME
CHEVRON STATION #307709*
STREET_NUMBER
10858
STREET_NAME
TRINITY
STREET_TYPE
PKWY
City
STOCKTON
Zip
95219
APN
06602015
CURRENT_STATUS
01
SITE_LOCATION
10858 TRINITY PKWY
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
380
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
F. In -Tank Gauging / SIR Equipment: r Check this box if tank gauging is used only for inventory control. <br />r Check this box if no tank gauging or SIR equipment is installed. <br />This section must be completed if in -tank gauging equipment is used to perform leak detection monitoring. <br />Complete the following checklist: <br />�* Yes <br />r No* <br />Has all input wiring been inspected for proper entry and termination, including testing for ground faults? <br />it Yes <br />(_ No* <br />Were all tank gauging probes visually inspected for damage and residue buildup? <br />G Yes <br />r No* <br />Was accuracy of system product level readings tested? <br />( Yes <br />(_ No* <br />Was accuracy of system water level readings tested? <br />(* Yes <br />r No* <br />ere all probes reinstalled properly? <br />Jr. Yes <br />C No* <br />1were all items on the equipment manufacturer's maintenance checklist completed? <br />* In the Section H, below, describe how and when these deficiencies were or will be corrected. <br />G. Line Leak Detectors (LLD): F Check this box if LLDs are not installed. <br />Complete the following checklist: <br />Yes <br />r No* <br />For equipment start-up or annual equipment certificationy .was a leak simulated to verify LLD performance? (Check all that <br />r N/A <br />apply) Simulated leak rate: F 3 g.p.h.; r 0.1 g.p.h; 1 0.2 g.p.h. <br />Yes <br />No* <br />Were all LLDs confirmed operational and accurate within regulatory requirements? <br />is Yes <br />No* <br />Was the testing apparatus properly calibrated? <br />(' Yes <br />i" No* <br />For mechanical LLDs, does the LLD restrict product flow if it detects a leak? <br />G N/A <br />f Yes <br />r- No* <br />For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? <br />r N/A <br />is Yes <br />r No* <br />For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? <br />i N/A <br />Yes <br />i" No* <br />For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? <br />r N/A <br />i+ Yes <br />(_ No* <br />For electronic LLDs, have all accessible wiring connections been visually inspected? <br />r N/A <br />G Yes <br />r No* <br />ere all items on the equipment manufacturer's maintenance checklist completed? <br />* In the Section H, below, describe how and when these deficiencies were or will be corrected. <br />reg and sup passed. die failed. <br />Page 3 of 4 12/07 <br />