My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012 - 2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRINITY
>
10858
>
2300 - Underground Storage Tank Program
>
PR0526212
>
COMPLIANCE INFO_2012 - 2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/28/2023 1:17:35 PM
Creation date
9/5/2018 2:09:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO_2012 - 2013
FileName_PostFix
2012 - 2013
RECORD_ID
PR0526212
PE
2351
FACILITY_ID
FA0017737
FACILITY_NAME
CHEVRON STATION #307709*
STREET_NUMBER
10858
STREET_NAME
TRINITY
STREET_TYPE
PKWY
City
STOCKTON
Zip
95219
APN
06602015
CURRENT_STATUS
01
SITE_LOCATION
10858 TRINITY PKWY
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
380
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t IUtJ—E-ZZ0I 1t ~-tom' t0idP FPOtrt <br />1925912566® P.1-1 <br />SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 Eeat Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 458-3420 Fax: (209) 463-3433 Web. www sigov.orci/ehd/unitiii.Mml <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Fadl ty <br />Name. Chevron 307709 <br />Faaaity <br />Address 10858 Trinity Parkway, Stockton <br />IrspeCion l <br />na,A Apr 27, 2012 <br />VIOLATIONS <br />;W <br />C1 C2 <br />1 M <br />C.d. Sattlon <br />NSG = GA VAaltn and Sat Codo- GFR = Code & Frndviwl R u1r,Lons <br />__. <br />C1 - Class 1 violation C2 = Class 2 violal€on' M = Minar YolWlon <br />Non-Pressurtsad Piping cnntlnIlad <br />702 <br />CCR 2643(e) Biennial lightness test of gravity piping not performed (pro -January 1. 1984) iV1) <br />703 <br />CCR 2643(d) Trianniat line test for conventional suction piping not performed (pre -January 1. 1984) 4�1) <br />Other Vlolattlons <br />pOp OtRer See attached "Continuation —Official Inspection Reporl" for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS ii or MINOR -Notice ter Ceen t <br />Routine and Monitoring System Certification UST Inspection <br />311. The Diesel line leak detector failed to detect a leak when tested. Ail line leak detector; shall be <br />capable of detecting a 3 -gallon per hour leak at 10 psi. immediately have a properly licensed, trained, <br />certified contractor repair or replace the failed leak detector (LG 113-x listed, if applicable) and <br />and <br />obtain a permit within one business day From the EHD. If the failed leak detector can't be replaced <br />immediately, there is a possibility that the Diesel UST system may be red tagged to prevent fuel inputs. j <br />313. The 87 octane spill container failed when tested. All spill containers shall have a minimum capacity <br />of five gallons and be capable of containing a spill or over -fill until it is detected or cleaned up. <br />Immediately contact a properly licensed, trained, and certified contractor to repair or replace the spill <br />container under permit and inspection of the Environmental Health [department (EHD). <br />406. The diesel product line (S6) and 87 octane vent Bine (S2) liquid sensors failed when tested. The <br />interstitial space of the UST system shall be maintained, as designed, under constant vacuum such that <br />a breach in the primary or secondary containment is detected before the hazardous substance is <br />immediately by having a properly licensed, trained, and certified <br />released into the environment. Correct <br />w'th a functional component (LG 113-x listed, if applicable) and <br />contractor replace the failed component <br />obtain a permit within one business day from the END. If the failed component can't be replaced <br />immediately, there is a possibility that the 87 octane and diesel UST system may be red tagged by the <br />EHD to prevent fuel inputs. <br />Note <br />1. Complete the following by May 27 2012 and send to the San Joaquin County Environmental Health <br />Department: <br />a. The Return to Compliance Certification form. <br />b. A statement explaining how each violation was corrected. <br />c. Supporting documentation. <br />ALL EHD STAFF TIME AssoctATED WTH FAILING TO COMPLY 8Y THF ABOVE NOTED HATES WILL SE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS St) ECT TO REINSPECTION AT ANY TIME AT EF-lt)'S CURRENT HOURLY RATE. <br />UST INSPECTION REPOM <br />2 Rev 091D1� <br />
The URL can be used to link to this page
Your browser does not support the video tag.