Laserfiche WebLink
Maximize protection with a vacuum <br />monitored secondary containment <br />system. <br />A Secondary Containment Vacuum <br />Sensing System for use with Veeder- <br />Root's ATG Systems. 1 he Secondary <br />Containment Vacuum Sensing (SCVS) <br />System is designed to detect leaks in double - <br />walled tanks and piping systems while <br />helping to contain a release of product while <br />under vacuum. The system consists of: <br />Vacuum Sensors, connected to tank, <br />sump or piping interstices <br />A Submersible Turbine Pump (STP), <br />to provide a source of vacuum <br />A Smart Sensor Interface with Embedded <br />Pressure Module in a TLS -350 <br />Monitoring System <br />The Vacuum Sensor is interfaced to Veeder- <br />Root's TLS -350 Monitoring System via <br />intrinsically safe wiring to provide system <br />status, replenish rate, alarm, and diagnostic <br />information. <br />Vacuum Sensor Kits are available in a variety <br />of models: <br />• For monitoring double -walled piping <br />and sump interstices <br />• For monitoring double -walled steel tank <br />interstices (see back page) <br />• For double -walled fiberglass tanks <br />These kits differ in the number of vacuum <br />sensors and the configuration of associated <br />liquid sensors. An inline kit mounted liquid <br />sensor is used for Vacuum Sensors <br />monitoring piping and sumps. An external <br />liquid sensor (to be installed in the secondary <br />space at the bottom of the tank) is provided <br />with one of the Vacuum Sensors in the steel <br />and fiberglass tank kits to monitor the tank. <br />Features acid Benefits <br />Sall Reqquvementc <br />• Certified to ineet Cahfomlats requirement for <br />secondary s mumtonng for tanks and litres <br />as required space <br />2481 <br />• Satisfies the requirements for Cla% I Leak <br />Detection as defined by the Europeart <br />Standard EN 13160-2 <br />• 3rd Pan}- National Vibrk Group and LG113 <br />listed <br />Redurc Exposuie to Risk <br />• Alams when vxmirrr cannot be maintained <br />or when repletttsh tate exceeds 85 liters per hour <br />• The system alamis when liquid is detected in <br />the gecorulm, space <br />Operating Temperature Rating: <br />25 degrees C to 170 degrees C <br />Cable Length: <br />8 feet <br />Sensor Dimensions: <br />5" high x 5" wide 2" deep <br />Facilitate` periodic opera - testing <br />Leverage Existing leeder-Root Systems <br />• Uses STP as the vacuum so= and works with <br />Red Jacket and FE 5 <br />• Installs in the STP surnp and connects to the <br />axLsole via intrmsi c safe wtri ig <br />• Able to dram wiring conduct with other <br />ceder --Ran mtnnsicA safe (15) probes acid <br />seniors including stump or brie leak sennas <br />• lnTffkes to the Smart Sensor Interfam with <br />Embeddul Pressum Module <br />• Provides for positrve shut dowry of pressurized <br />Lncs when requited <br />• Sunple it srallanon, no creed to mess with brute <br />Console Capability <br />The Vacuum Sensor is compatible with <br />the following consoles: <br />Console <br />TLS-350FVEMC w/BIR' <br />TLS -350 Plus EMC Enhanced' <br />TLS-350/EMC' <br />'Upgrade Note: The Vacuum Sensor System requires <br />the console to have version 24C software (or greater) <br />along with an ECPU2 or ECPU w; NVMEM 1 board. <br />Standard Models <br />Veeder-Root P/N Description <br />Accessories Part Description Quantity/Length Part Number <br />Kits Include mounting bracket V of vacuum lase, refief valve ansembl, (f required) and the app,rpriate number of squid sensors, <br />i-way ball vat as, barbed fittings and hose damps so that each vacuum sensor can monitor a single tank, sump or piping interstices. <br />'• The Vacuum Sensing S)stem requires one 7 channel Smart Sensor Interface v,ith Embedded Pressure Module. 8 darnel Smart <br />Sensor Mc lutes (p n 329356-004) can be used for Vacurn Sensors eight and above. <br />For more Information call 1-888-561-7942 <br />VEEDER-ROOT <br />