Laserfiche WebLink
San Joaquin County <br />Environmental Health Department <br />_mss ' •.OG <br />600 East Main Street <br />LA:{ Stockton, California 95202-3029 <br />Website: www.sjgov.org/ehd <br />�%FOR <br />Vlay 5 2010 Phone: (209) 468-3420 <br />Fax: (209) 464-0138 <br />Lucy Silvas-Thomas <br />Town & Country Contractors, Inc. <br />3181 Luyung Drive, Suite A <br />Rancho Cordova, CA 95742 <br />Re: Chevron, 10858 Trinity Parkway, Stockton, CA 95219 <br />DIRECTOR <br />Donna Heran, REHS <br />PROGRAM COORDINATORS <br />Robert McClellon, REHS <br />Jeff Carruesco, REHS, RDI <br />Kasey Foley, REHS <br />SR0059375 <br />The San Joaquin County Environmental Health Department (EHD) has completed the review of <br />the AMENDED application for a permit to install Bravo B-401 tank top sumps and collars, Bravo <br />F -17 -RR -D penetration fittings, Fiberglass Systems penetration fittings, Fiberglass Systems Red <br />Thread IIA pipe and Bravo under dispenser containments (UDCs) (68000) on the underground <br />storage tank (UST) system at the above noted address. The permit has been approved with the <br />following conditions: <br />Contact the local fire department and the San Joaquin Valley Air Pollution Control <br />District for any applicable permits and requirements. <br />2. Any changes in information and scope of work must be submitted to EHD for approval <br />prior to commencing work. All new addenda supersede the previous ones. <br />3. Contact Garrett Backus at (209) 468-2986 to arrange the following inspection <br />appointments (a 48-hour notice is required for inspection appointments). <br />a. Soil sampling under the UDCs being removed. <br />b. Primary product piping soap test: One hour pneumatic pressure test at 110% of <br />operating pressure, or 40 psi, whichever is greater. <br />c. Primary vent and vapor piping soap test: One hour pneumatic pressure test at 110% <br />of operating pressure, or 5 psi, whichever is greater. <br />d. Secondary containment (UDCs, tank top sumps and v t�sump�) soap test: One hour <br />pressure test of the sump interstitial space per sump manufaccpurer's guidelines. If <br />there are no manufacturer's guidelines, test shall be performed using an applicable <br />method specified in an industry code or engineering standard. <br />e. Secary product,v�pt and va or piping soaptest: One hour pressure test per <br />manufacturer's guidelines. If there are no manufacturer's guidelines, test shall be <br />performed using an applicable method specified in an industry code or engineering <br />standard. <br />f. 24-hour hydrostatic test (or equivalent) on UDCs, tank top sumps and vent sump, <br />after backfill. <br />g. Sensor functionality: Functionality of the monitoring system must be verified to <br />ensure that monitoring has been restored to meet the requirements of Title 23 <br />California Code of Regulations and the Health & Safety Code. <br />