My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010 - 2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRINITY
>
10858
>
2300 - Underground Storage Tank Program
>
PR0526212
>
COMPLIANCE INFO_2010 - 2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/28/2023 1:15:12 PM
Creation date
9/5/2018 3:57:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO_2010 - 2011
FileName_PostFix
2010 - 2011
RECORD_ID
PR0526212
PE
2351
FACILITY_ID
FA0017737
FACILITY_NAME
CHEVRON STATION #307709*
STREET_NUMBER
10858
STREET_NAME
TRINITY
STREET_TYPE
PKWY
City
STOCKTON
Zip
95219
APN
06602015
CURRENT_STATUS
01
SITE_LOCATION
10858 TRINITY PKWY
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
243
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN .JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd/unitiii.htmi <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br />Facility name: <br />Inspection date: <br />Chevron 307709 <br />April 29, 2011 <br />Facility address: <br />UST # / <br />1 <br />2 <br />3 <br />10858 Trinity Parkway, Stockton <br />Product <br />87 <br />91 <br />DSL <br />Facility contact: Title: Phone: <br />Rosella Biggs Manager 952-2213 <br />Monitoring panel: <br />Piping system: <br />Overfill prevention: <br />Violations: <br />Veeder-Root TLS -350 <br />❑XPressurizedauction ❑Gravity <br />❑Mechanical <br />DAudible/visual <br />OM1-RDetect❑M2-RPrev❑M3-Both <br />Inspection type: <br />Designated operator: ICC exp. date: <br />ORoutine ❑X Monitoring Certification ❑Installation ❑Other <br />Edward Dahlgren 9-28-12 <br />On site Service Technician's name: ICC exp. date: <br />Manufacturer's training: <br />Tim Elebeck 11-30-12 <br />VR level 4. 9-11-11 <br /># <br />Code Section <br />VIO <br />V <br />HSC=CA Health & SafetyCode; CCR=CAC d`e of Regulations; V=Violation; RV=Re eat Violation <br />V <br />1 <br />HSC 25284 <br />No permit to operate <br />Secondary containment: (a) test not performed; (e) test report not submitted within 30 days; (f) test <br />2 <br />CCR 2637 <br />notification not provided to the Environmental Health Department (EHD) at least 48 hours prior to <br />conducting the test <br />3 <br />CCR 2711 b <br />Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form <br />4 <br />HSC 25292.2 <br />Current financial responsibility documents not on file with the EHD <br />5 <br />CCR 2632(b) <br />Monitoring Program(Monitoring & Response Plans is not current or approved by the EHD <br />6 <br />CCR 2712(i) <br />Monitoring Ian, response plan, and/oroperating permit and all conditions not onsite <br />Maintenance & monitoring records not maintained 3 years, cathodic protection records for 6 % (M7) <br />years, written performance claims pertaining to release detection systems for 5 years, or records of <br />repairs, linings, and upgrades for the life of the tank. Monitoring records include: (1) date and time of <br />7 <br />CCR 2712(b) <br />all monitoring or sampling; (2) monitoring equipment calibration and maintenance records; (3) results <br />of any visual observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all <br />readings of gauges or other monitoring equipment, ground water elevations, or other test results; (6) <br />results of inventory readings and reconciliations <br />8 <br />CCR 2643(d) <br />Daily monitoring of suction piping (pre-January1, 1984 not performed (Mil <br />9 <br />HSC 25292.1 <br />UST system is not --rated to revent unauthorized release, including spills and overfills <br />CCR 2632 c 2 <br />Monitoringsystem is not resent in the interstitials ace of a double waited UST (M1) <br />' <br />11 <br />CCR 2630(d) <br />UST monitoringequipment is not installed or maintained to detect a leak at the earliest o rtunit (M1) <br />r1210 <br />HSC 25291(b) <br />UST monitoring system incapable of detecting leak from primary containment into secondary (Mi) <br />containment <br />Failed to maintain a continuous monitoring system for underground piping & UDCs that activates (Mt) <br />13 <br />CCR 2636(f)(1) <br />an audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br />� <br />14 <br />CCR. 2631 a) <br />Primary containment is not product tight <br />25291 a �Z <br />Se_condar containment for UST system is not tight ______ __CCR <br />E15HSC <br />2636 c 1 <br />All releases in seconds piping do not flow to a collection sump <br />17 <br />CCR 2636(f)(2) <br />Line leak detector(s) not installed or failed to detect a anon per hour leak at 10 psi (M'1 <br />X <br />Spill container failed to contain a minimum capacity of fire gallons, or failed to provide a means (m2) <br />18 <br />CCR 2635 b (1) <br />() <br />to keepthe spill ecntainer empty <br />19 <br />CCR 2635(b)(2) <br />Overfill prevention system was overridden or failed to meet overfill requirements in this section (M2) <br />20 <br />CCR 2636(a) <br />Failed to have secondary containment for piping (includes conventional suction piping) (Md) <br />21 <br />HSC 25291�e�__ <br />Water in 20 containment not removed, analyzed &prapedy disposed <br />Unauthorized release that: (c) did not escape secondary containment and cleaned up within eight (M1) <br />22 <br />CCR 2650 <br />hours was not recorded; (e) escaped secondary containment, not cleaned up after eight hours, or a <br />sudden loss of product was not reported to the EHD within 24 hours <br />23a <br />CCR 2715(a) <br />Failed to inform the EHD of a chane of designated operator within 30 days <br />23b <br />CCR 2715(b) <br />Designated operator did not possess a current ICC UST System Operator Certification <br />EHD inspector: Y I <br />Titl: <br />Re y:J,4 <br />r1 _ _n2 RFL (1F!'1 liq 3 a 1 ICT IN.P=(`T1f-1N PFP0PT <br />6 <br />�GYKe <br />
The URL can be used to link to this page
Your browser does not support the video tag.