Laserfiche WebLink
MONITC "ING SYSTEM CERTIFIC TION <br />F ;e By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3 Title 23, Camomia Code of Regulations <br />This form mus=e d to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility, a separate <br />certification ormust be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br />system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: QUICK STUFF #7789 <br />Site Address: 10858 TRINITY PKWY <br />City: STOCKTON <br />Contact Phone No: 952-2213 <br />@ 8 MILE WEST OF HWY 5 Date of Testing/Service: 06/24/2009 <br />Facility Contact Person: MGR - DAVID COOPER <br />Make/Model of Monitoring System: TLS 350 <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate specific equipment inspected/serviced <br />Work Order Number: 2267343 <br />CA Zip: 95210 <br />Tank ID: 87 <br />Tank ID: 91 <br />In -Tank Gauging Probe. <br />Model: MAG <br />❑X In -Tank Gauging Probe. <br />Model: MAG <br />Annular Space or Vault Sensor. <br />Model: <br />❑ Annular Space or Vault Sensor. <br />Model: <br />X Piping Sump/Trench Sensor(s). <br />Model: 208 SMART SENSORS <br />© Piping Sumprrrench Sensor(s). <br />Model: 208 SMART SENSORS <br />Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />Tank Overfill/High-Level Sensor. <br />Model: <br />0 Tank Overfill/High-Level Sensor. <br />Model: <br />Other (specify equipment type and <br />model in Section E on page 2). <br />11 Other (specify equipment type and model in Section E on page 2). <br />Tank ID: LISIL <br />Tank ID: <br />71 In -Tank Gauging Probe. <br />Model: MAG <br />❑ In -Tank Gauging Probe. <br />Model: <br />Annular Space or Vault Sensor. <br />Model: <br />❑ Annular Space or Vault Sensor. <br />Model: <br />X Piping Sump/Trench Sensor(s). <br />Model: 208 SMART SENSORS <br />❑ Piping Sump/Trench Sensor(s). <br />Model: <br />Fill Sump Sensor(s). <br />Model: <br />Fill Sump Sensor(s). <br />Model: <br />Mechanical Line Leak Detector. <br />Model: <br />Mechanical Line Leak Detector. <br />Model: <br />Electronic Line Leak Detector. <br />Model: <br />Electronic Line Leak Detector. <br />Model: <br />Tank Overfill/High-Level Sensor. <br />Model: <br />❑ Tank Overfill/High-Level Sensor. <br />Model: <br />Other (specify equipment type and <br />model in Section E on page 2). <br />❑ Other (specify equipment type and model in Section E on page 2). <br />Dispenser <br />Dispenser ID: <br />❑ Dispenser Containment Sensor(s) <br />Model: <br />❑ Dispenser Containment Sensor(s) <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s) <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containment Sensor(s) <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containment Sensor(s) <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />10 Dispenser Containment Float(s) and Chain(s). <br />C Dispenser Containment Float(s) and Chain(s). <br />* If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification <br />I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. <br />Attached to this certification is information (e.g manufacturers' checklists) necessary to verify that this information is correct. <br />and a Site Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached <br />a copy of the (Check all that apply): -X System set-up X❑ Alarm history report <br />Technician Name (print): KRISTOPHER BELL <br />Signature: <br />Certification No.: B33709 License. No.: 743160 (Class 'A' General Enginering Contractor License) <br />Testing Company Name:Tanknology Phone No.: (800) 800-4633 <br />Site Address: 8501 N. MoPac Expressway, suite 400, Austin, TX 78759 Date of Testing/Servicing: 06/24/2009 <br />Monitoring System Certification Page 1 of 3 Based on CA form dated 03/01 <br />