My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
86-1461
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
RYDE
>
0
>
4200/4300 - Liquid Waste/Water Well Permits
>
86-1461
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/2/2019 10:19:25 PM
Creation date
12/1/2017 7:43:06 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200/4300 - Liquid Waste/Water Well Permits
RECORD_ID
86-1461
STREET_NAME
RDYE
STREET_TYPE
AVE
City
STOCKTON
SITE_LOCATION
E/S RYDE AVE 50' S/ 0 PIXIE DR
Supplemental fields
FilePath
\MIGRATIONS\R\RYDE\0\86-1461.PDF
QuestysFileName
86-1461
QuestysRecordID
1913062
QuestysRecordType
12
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
{ 2 a <br /> 5 <br /> 77 T T1t7 �.`�jf c rip p Q�rrl T��7 .. ..._ }IATE-iiRac FOR QEEP YELL ANODES <br /> �L✓AIER /�[�/sf s7G/7Lu /7d P /1 a7/�/Y I7MR11IN.[NVNr7 DESCRIPTION CSE NO <br /> i TEN OCTANT <br /> yE/g,CTj/ D/STJT/fT p ANODES 3'K84"Ql1RICHLOfl 51 TYPE 7A-3 WI IN 56-9353 � <br /> a7la/VD3. 60aLBS COKE 125' •B EPE WIRE 56 9086 <br /> BREEZE BACKFILL 25 OHM-CM OR LE <br /> VALVE_ FRAME 12 2 SS — 29--4376 <br /> & COVER Ia —SEE NOTE I 3 AS RF0'0 WIRE •10 ANG RHWI N OR HMWPE — — <br /> _ -CONDttIT TO POLF MOUNIED OR 4 B PIPE CLAMPS 6 CENTERING GUIDE <br /> _ LNGERGROUNA RECTIFIER• ISEE GS 0-II.t1. 5 I 1-1/4" ABS PLASTIC IBO' TURN <br /> J. YRAP UNDERGROUND PORTION Of L'ONDUiT 36 0459 <br /> --- - r-------- 1` WITH PLASTIC TAPE IF CONDUIT IS METALLIC, 6 141 I-1/4_ ABS PL?ST71 DUCT TYPE DET <br /> . s rr�,, T 1 1-I/4' TEMP PLASTIC CAP <br /> r 3) 8 30 PLASTIC TIE LOCKS <br /> •t SEAL CND OF CONDUIT WITH TAC-1APE 9A I VALVE FRAME <br /> \_.. --------- SEE GAS SID K40-K40.1 <br /> CODE 50-7436. {AQUA SEAL, CGDE ;0-7430 9B I 12' EXTENSION <br /> r MAT BE 'JS-D. BUT TAC-IAP[ 9C I VALVE 6OX COVER <br /> " IS PRZFERRFD FOR GAS DEPARTMENT USTI <br /> 6 TO 1 TEST LEAD BOX. SEE GAS STD 0-10. I <br /> i 1 1 S REO-D CONCRETE <br /> 1 12 1. !. ISPLJDL, ANODE WIRE, SEE GAS STD,C 12 <br /> /SEE NOTE H <br /> , I WELDING ROD <br /> is <br /> D DEV I Lt irTG <br /> FOR INSTAEIATION:PROCEDURE NOTES: <br /> ( 'ISE NOTm D/4' ANODE D/Y ANODE " <br /> A" DRILL A 13' DIAMETER HOLE k20 FT DEEP Al CHOSEN LOCATION. <br /> R SEE itOlE ASSEMISiE ANODES AMD I-1/4'DUCT AS SHOWN-OBSERVE SPACING. <br /> a <br /> C. TAPE DR STRAP ANODE WIRE TO THE OUTSIDE OF THE VENT PIAT EVERY 4'. <br /> -BEND D. NOTIFr THE RESPONSIBLE DISTRI'T CAT DIVISION ENGINEER WHEN ANODES ARE TO <br /> BE INS WITH <br /> W THAI HE OR A CORROSION MECHANIC CAN BE PRESENT. <br /> E' WHEN USING kam TO SI�POST THE GAS-LS OF THE HALE. THIN Mu0 ou' WITH <br /> 1 I/4" <br /> CONDUIT. CLEAR WATER PRIOR ID INSTALLING [OKE DREtZE. <br /> f. IGWER.ASSENBLEO ANODE yTRlNG AMD 1-1i4*OUCT INTO HOLE u513i( SU <br /> lTA$LL LINE. <br /> CLAPP. CHAIN LINA UNTIL CONTACT W{T'H VITO$* IS MADE. BE CAREFUL Wil ANODE LEAD VIRES. <br /> � ,- FENCE. SIZED TO ir. HOLD ANODES iH POSITID% AND KEEP WIRES TAUT WHILE PCAIRING SN 600 LBS. <br /> 1 Eli ANODE Df [CINE BREEZE, i4EASURE DEPTH TO TOP Of COKE iMtEZE. TOP of COKE <br /> C i ANODE GLIDE CAV ESE EITHLR BREEZE COLUMN SHALL $E 44 FiET FROM SURFACE. ADD LUKE RREEIE <br /> r LDE:; TO CLAM" OR CLAMPCD' AS REO>.IREQ. <br /> I 10 ANODE AND BENT 10 SLIAPE H. DIEL HOLE WITH CONCRETE tEtASS B MIX-i SACKS OF PORTLAND CEMENT PER <br /> EE �T:1�='_ (DE_P WELL) ANODE CENTERING DEVICE CUBIC YARD). <br /> DETAIL NAn F• SEE GAS <br /> SHEAR STANDAOF <br /> RD 0-10. MAY not OPTIONS. <br /> ALSO BE SPLICED INSIDE UNEIERGROUND RECTIFIER CONCRETE BOX IGS 0 11.11. <br /> ALL WORK SHALL BE DOME IN ACCORDANCE WITH DEPT. OF WATER RESOURCES <br /> BUELEIrIN, WATER WELLS b CATHODIC PROTECTION WELLS (SEC 13700-13806 <br /> CALIF. MATER CODE). <br /> 4 <br /> ---- "� NOTE: <br /> - <br /> 1 1. SLOTS FOR VENTILATION OF CHLORINE.GAS SHALL EE INSERTED IN <br /> I�- THE LOWER 30' OF THE 1-1/4• ABS DUCT. EA'--H SLOT SHALL BE <br /> 3'I <br /> ROTATED 94' FROM. THE PREVIOUS SLOT. CUT SLOT W,CIRCULAR SAW. <br /> B I` — 1_ 2"X k%I E" SLOT ` , INS7/91L f9 !✓HTfR t// ex V!a/VE <br /> TYPNOTE 11 <br /> TYPICAL <br /> LAS RND INSftT <br /> I <br /> / 3. I/V�TAlI G/Alfi? T/ENT SEA! <br /> T eN f� RM 1,49111c,616. ` <br /> - <br /> - SEE DEIAT�'•E <br /> . --s- <br /> VENTILATION S►OTS CENTERING GUILE. - L <br /> €}ETAiL':,•"E" $ E:710" A r P <br /> sk " er�T ar wTr C <br /> �►, ,- a.)scn acur� A arw.a wt^ ' P I P ING—DATA SHEET . oti ust <br /> {r °�+,i s r 3. T ..�. P[M1SEa 0 179' tsfLG f WILE_:•_.– "'• y SWo505 N <br /> ' A ,Poor.=sn)ce r_eETEa1au eoLntw- s s ILtSiALEATIOtt OF aM0ElE5 � <br /> P► Ni PIA PAL i 20' DEEP S,�Ert <br /> ! - 5 -77• Pi 15 V OETEN NEA {MERE r .PTA lrAt �'."-: {HEEL PD. <br /> 1 7•it•! PErlsEn NDTCS CtN.ED DI3'T t- ••:^ - AA i>A GAS STAN4ARD A[r• <br /> 2 8 3 8 3 5 8 <br /> PACEflt 6115 AT+I� ELECTRIC COMPANTF . <br /> _ :.: CJT ... SA1t FRIfNtI <br /> c- <br /> - .e.tsr w�ei[a w•nOp w•�.au,nm an _ -�k T ait` _ a.�9� .^,"" ---–J---—v� <br />
The URL can be used to link to this page
Your browser does not support the video tag.