Laserfiche WebLink
INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br />i Tanknology <br />8501 N MOPAC EXPRESSWAY, SUITE 400 <br />TEST DATE: 12/28/07 <br />AUSTIN, TEXAS 78759 (512) 451-6334 <br />WORK ORDER NUMBER: 2253662 <br />CLIENT: JMM MANAGEMENT GROUP, <br />SITE: QUICK STUFF #7789 <br />TANK INFORMATION <br />Tank ID: 1 <br />Tank manifolded: No <br />Bottorn to top fill in inches: 118.0 <br />Product: UNLEADED <br />Vent manifolded: YES <br />Bottom to grade in inches: <br />Capacity in gallons: 19,703 Vapor recovery manifolded: YES <br />Fill pipe length in inches: <br />Diameter in inches: 118.00 <br />Overfill protection: YES <br />Fill pipe diameter in inches: <br />Length in inches: 420 <br />Overspill protection: YES <br />Stage I vapor recovery: DUAL <br />Material: DW FIBERG <br />Installed: ATG and CP <br />Stage II vapor recovery: ASSIST <br />CP installed on: <br />COMMENTS <br />TANK TEST RESULTS Test Method: NONE <br />LEAK DETECTOR TEST RESULTS <br />Test method: <br />PSI at tank bottom: <br />New/passed <br />Failed/replaced New/passed Failed/replaced <br />Fluid level in inches: <br />L.D. #1 <br />L.D. #1 L.D. #2 L.D. #2 <br />UFT/OFT: <br />Make: <br />Fluid volume in gallons: <br />Model: <br />Tank water level in inches: <br />S/N: <br />Test time: NOT <br />Open time in sec: <br />Number of thermisters: TESTED <br />Holding psi: <br />NOT NOT <br />Specific gravity: <br />Resiliency cc: TESTED TESTED <br />Water table depth in inches: <br />Test leak rate ml/m: <br />Determined by (method): <br />Metering psi: <br />Leak rate in gph: <br />Calib. leak in gph: <br />Result: <br />Results: <br />COMMENTS <br />COMMENTS <br />ULLAGE TEST RESULTSTest Method: NONE <br />LINE TEST RESULTS <br />Test type: TLD -1 <br />Test time: <br />Ullage volume: <br />Material: DW FIBERG <br />Ullage pressure: <br />Diameter (in): 2.0 <br />Results: <br />Length (ft): 200.0 <br />Test psi: 50 <br />DATA FOR i ONLY: <br />Bleedback cc: 100 <br />Time of test 1: <br />Test time (min): 30 <br />Temperature: NOT <br />Start time: 09 : 42 <br />NOT NOT NOT <br />Flow rate (cfh): TESTED <br />End time: 12 : 25 <br />TESTED TESTED TESTED <br />Time of test 2: <br />Final gph: 0.014 <br />Temperature: <br />Result: PASS <br />Flow rate (cfh): <br />Pump type: PRESSURE <br />Time of test 3: <br />Pump make: FE PETRO <br />Temperature: <br />Flow rate (cfh): <br />Impact Valves Operational: YES <br />COMMENTS <br />COMMENTS <br />Printed 01/14/2008 08:31 ACRAMER <br />