Laserfiche WebLink
INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br />ZAP, Tanknology <br />8501 N MOPAC EXPRESSWAY, SUITE 400 <br />TEST DATE: 11/13/07 AUSTIN, TEXAS 78759 (512) 451-6334 WORK ORDER NUMBER: 2252487 <br />CLIENT: JMM MANAGEMENT GROUP, SITE: QUICK STUFF #7789 <br />Printed 11/29/2007 08:31 ACRAMER <br />TANK INFORMATION <br />Tank ID: 3 <br />Tank manifolded: NO Bottom to top fill in inches: <br />118.0 <br />Product: DIESEL <br />Vent manifolded: No Bottom to grade in inches: <br />Capacity in gallons: 7,817 <br />Vapor recovery manifolded: No Fill pipe length in inches: <br />Diameter in inches: 118.00 <br />Overfill protection: YES Fill pipe diameter in inches: <br />Length in inches: 167 <br />Overspill protection: YES Stage I vapor recovery: <br />NONE <br />Material: DW FIBERG <br />Installed: ATG Stage II vapor recovery: <br />NONE <br />CP installed on: <br />COMMENTS <br />TANK TEST RESULTS Test Method: <br />LEAK DETECTOR TEST RESULTS Test method: <br />; <br />PSI at tank bottom: <br />New/passed Failed/replaced New/passed <br />Failed/replaced <br />Fluid level in inches: <br />L.D. #1 L.D. #1 L.D. #2 <br />L.D. #2 <br />UFT/OFT: <br />Make: FE PETRO <br />Fluid volume in gallons: <br />Model: MLD <br />Tank water level in inches: <br />S/N: 06050884 <br />Test time: <br />NOT <br />Open time in sec: 3.00 <br />Number Of thermisters: <br />TESTED <br />Holding psi: 4 <br />NOT <br />Specific gravity: <br />Resiliency cc: 40 TESTED <br />Water table depth in inches: <br />Test leak rate ml/m: 189.0 <br />Determined by (method): <br />Metering psi: 17 <br />Leak rate in gph: <br />Calib. leak in gph: 3.00 <br />Result: <br />Results: PASS <br />COMMENTS <br />COMMENTS <br />ULLAGE TEST RESULTSTest Method: <br />LINE TEST RESULTS Test type <br />LINE A <br />Test time: <br />Material: DW FIBERG <br />Ullage volume: <br />Diameter (in): <br />Ullage pressure: <br />Length (ft): <br />Results: <br />Test psi: <br />Bleedback cc: <br />Test time (min): <br />DATA FOR UTS-4T ONLY: <br />Test 1: Start time: <br />Time of test 1: <br />Finish psi: NOT NOT NOT <br />NOT <br />Temperature: <br />NOT <br />Vol change cc: <br />Test 2: Start time: TESTED TESTED TESTED <br />TESTED <br />Flow rate (cfh): TESTED <br />Finish psi: <br />Time of test 2: <br />Vol change cc: <br />Test 3: Start time: <br />Temperature: <br />Finish psi: <br />Flow rate (cfh): <br />Vol change cc: <br />Time of test 3: <br />Final gph: <br />Temperature: <br />Result: <br />Flow rate (cfh): <br />Pump type: PRESSURE <br />COMMENTS <br />Pump make: FE PETRO <br />COMMENTS Impact Valves Operational: UNKNOWN <br />Printed 11/29/2007 08:31 ACRAMER <br />