My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006 - 2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRINITY
>
10858
>
2300 - Underground Storage Tank Program
>
PR0526212
>
COMPLIANCE INFO_2006 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/7/2018 2:32:22 PM
Creation date
9/7/2018 2:01:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO_2006 - 2008
FileName_PostFix
2006 - 2008
RECORD_ID
PR0526212
PE
2351
FACILITY_ID
FA0017737
FACILITY_NAME
CHEVRON STATION #307709*
STREET_NUMBER
10858
STREET_NAME
TRINITY
STREET_TYPE
PKWY
City
STOCKTON
Zip
95219
APN
06602015
CURRENT_STATUS
01
SITE_LOCATION
10858 TRINITY PKWY
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
240
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br />41110-1 `P, Tan <br />8501 N MOPAC EXPRESSWAY, SUITE 400 <br />TEST DATE: 10/17/08 AUSTIN, TEXAS 78759 (512) 451-6334 WORK ORDER NUMBER: 2260455 <br />CLIENT: JMM MANAGEMENT GROUP, SITE: QUICK STUFF #7789 <br />r fll��l n INFORMATION4%A . -1"; <br />Tank ID: 1 <br />Tank manifolded: NO <br />Bottom to top fill in inches: 118.0 <br />Product: UNLEADED <br />Vent manifolded: YES <br />Bottom to grade in inches: <br />Capacity in gallons: 19,703 <br />Vapor recovery manifolded: YES <br />Fill pipe length in inches: <br />Diameter in inches: 118.00 <br />Overfill protection: YES <br />Fill pipe diameter in inches: <br />Length in inches: 420 <br />Overspill protection: YES <br />Stage I vapor recovery: DUAL <br />Material: DW FIBERG <br />Installed: ATG and CP Stage II vapor recovery: ASSIST <br />CP installed on: <br />COMMENTS <br />TANK TEST RESULTS Test Method: <br />LEAK DETECTOR TEST RESULTS Test method: <br />PSI at tank bottom: <br />New/passed Failed/replaced New/passed Failed/replaced <br />Fluid level in inches: <br />L.D. #1 L.D. #1 L.D. #2 L.D. #2 <br />UFT/OFT: <br />Make: <br />FE PETRO <br />Fluid volume in gallons: <br />Model: <br />MLD <br />Tank water level in inches: <br />S/N: <br />UNREADABLE <br />Test time: <br />NOT <br />Open time in sec: <br />6.00 <br />Number of thermisters: <br />TESTED <br />Holding psi: <br />23 NOT <br />Specific gravity: <br />Resiliency cc: <br />245 TESTED <br />Water table depth in inches: <br />Test leak rate ml/m: <br />189.0 <br />Determined by (method): <br />Metering psi: <br />10 <br />Leak rate in gph: <br />Calib. leak in gph: <br />3.00 <br />Result: <br />Results: <br />PASS <br />COMMENTS <br />COMMENTS <br />ULLAGE TEST RESULTSTest Method: <br />LINE TEST RESULTS <br />Test type: <br />Test time: <br />Material: DW <br />FIBERG <br />Ullage volume: <br />Diameter (in): <br />2.0 <br />Ullage pressure: <br />Length (ft): <br />200.0 <br />Results: <br />Test psi: <br />Bleedback cc: <br />Test time (min): <br />DATA FOR UTS-4T ONLY: <br />Test 1: Start time: <br />Time of test 1: <br />Finish psi: <br />NOT NOT NOT NOT <br />Temperature: <br />NOT <br />Vol change cc: <br />Test 2: Start time: <br />TESTED TESTED TESTED TESTED <br />Flow rate (cfh): TESTED <br />Finish psi: <br />Time of test 2: <br />Vol change cc: <br />Test 3: Start time: <br />Temperature: <br />Finish psi: <br />Flow rate (cfh): <br />Vol change cc: <br />Time of test 3: <br />Final gph: <br />Temperature: <br />Result: <br />Flow rate (cfh): <br />Pump type: PRESSURE <br />COMMENTS <br />Pump make: FE PETRO <br />COMMENTS <br />Impact Valves Operational: UNKNOWN <br />Printed 10/30/2008 09:05 ACRAMER <br />