My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006 - 2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRINITY
>
10858
>
2300 - Underground Storage Tank Program
>
PR0526212
>
COMPLIANCE INFO_2006 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/7/2018 2:32:22 PM
Creation date
9/7/2018 2:01:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO_2006 - 2008
FileName_PostFix
2006 - 2008
RECORD_ID
PR0526212
PE
2351
FACILITY_ID
FA0017737
FACILITY_NAME
CHEVRON STATION #307709*
STREET_NUMBER
10858
STREET_NAME
TRINITY
STREET_TYPE
PKWY
City
STOCKTON
Zip
95219
APN
06602015
CURRENT_STATUS
01
SITE_LOCATION
10858 TRINITY PKWY
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
240
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Site Address 10858 TRINITY PKWY <br />D. Results of Testing/Servicing <br />Software Version Installed: 327.04 <br />Complete the following checklist: <br />-)nitoring System Certification <br />Date of Testing/Service: 10/17/2008 <br />X Yes <br />❑ No <br />Is the audible alarm operational? <br />❑X Yes <br />❑ No <br />Is the visual alarm operational? <br />❑ Yes <br />X No <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />M Yes <br />❑ No " <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not <br />interfere with their proper operation? <br />X Yes <br />❑ No " <br />N/A <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) operational? <br />0 Yes <br />❑ No <br />❑ N/A <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive <br />shut -down? (check all that apply) ❑X Sump/Trench Sensors; ❑X Dispenser Containment Sensors. <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection? ❑X Yes ❑ No <br />❑ Yes <br />E No'❑ <br />N/A <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e.: no mechanical <br />overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill points(s) and operating <br />properly? If so, at what percent of tank capacity does the alarm trigger? % <br />❑ Yes" <br />❑X No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the <br />manufacturer name and model for all replacement parts in Section E, below. <br />❑X Yes" <br />❑ No <br />Was liquid found inside any secondary containment systems designed as dry systems? (check all that apply) ❑ Product; <br />❑X Water. If yes, describe causes in Section E, below. <br />❑x Yes <br />❑ No' <br />Was monitoring system set-up reviewed to ensure proper settings? Attach set-up reports, if applicable. <br />❑X Yes <br />❑ No <br />Is all monitoring equipment operational per manufacturers' specifications? <br />' In Section E below, describe how and when these deficiences were or will be corrected. <br />Comments: <br />3111: ILZWTED DUE TO SUMPS BEING 7 FT NEED SECOND MAN ON SITE. LITTLE WATER IN LL SUMPS FROM <br />Page 2 of 3 Based on CA form dated 03/01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.