Laserfiche WebLink
"w ue'' f11 V1 f 1I L X11. <br />SITE PLAN CHECKLIST V11 I <br />Thb followib2 information must be shown on your site plan before our department can begin Processing ourappliiiication. <br />INFt3RMATION 1NEEDED FOR COMPLETE MAp <br />ITEM . <br />{TEM, <br />ITEM NOT <br />COMPLET E` <br />NEfbED- <br />REQUIRED`,' <br />Size: The Site Plan must be drawn on minimum 18"x 24" material. <br />North Arrow, Date and Scale: Use an engineer's scale (i.e., 1" -to 20' or 1." to 40', <br />preferred). The direction of "north" should be pointing towards the top of the page. <br />Streets and Easements: Location and namesof all streets and easements bordering on <br />the propewith access details. <br />/ <br />Pro a Lines: All property lines or boundary lines of the parcel with dimensions. <br />Vicinity Map: A vicinity map showing the location of the property in relation to <br />surrounding streets. <br />Existing and Proposed Development: All existing structures (labeled 'existing') and any <br />proposed structures (labeled 'proposed') with dimensions, square footage and distances <br />from other structures and property lines. Any existing structures planned for removal <br />.. - <br />should be shown with dashed lines. The use and number of floors should be labeled on <br />each structure. <br />Parking and Driveways: The location, dimensions and surface material of all existing <br />J <br />_ <br />and proposed parking and driveways: Calculations indicating the number of required <br />spaces must be shown.. (Refer to 'Coun Parkin Lot Standards' .- <br />WaterWells: The location of existing and proposed water wells on-site and any off -sit <br />wells within 150' of the proposed development. Wells must be meet the following <br />setbacks: <br />- 5' from structures; <br />- 50' from septic tanks; <br />- 100' from leach lines; <br />y <br />- 150' from sumps or seepage pits; and <br />- 10' from property lines. <br />If public water will be utilized; a "will -serve" letter must be submitted from the service <br />provider <br />Sewers and Septic Tanks: The location of the sewer outlet, public sewer hook-up, or <br />existing and proposed sewage disposal systems and any off-site sewage disposal <br />systems within 150' of the property. Septic tanks must meet the following setbacks: <br />5' from property lines, structures, driveways and swimming pools; <br />50' from water wells. <br />Leach lines must meet the following setbacks: <br />10' from structures, driveways and swimming pools; <br />100' from wells, streams and waterways. <br />5' to 75' from property lines depending on zoning or the location of septic <br />systems on adjoining <br />properties (this requirement also applies to seepage pits). <br />If public sewage disposal will be utilized, a "will -serve" letter must -be submitted from the <br />service provider. <br />Storm Drainage: The location of existing and proposed orm dfainage facilities(check <br />rl <br />with Engineering staff regarding design criteria): -If subject to flooding, the 100 -year <br />flood elevations must be shown. Indicate <br />h� <br />any unusual topographic features of the site <br />(e.g. steep slopes, or drainage courses). <br />Landscaping: The location of existing and proposed landscaping and trees 6" or greater <br />in diameter (note any trees to be removed). Calculation indicating the percentage of the <br />net site area to be landscaped must be shown, (Refer to County Landscaping <br />% <br />Standards). <br />Signs, Fences, Storage and Trash Enclosures: The location of and height of all existing <br />and proposed signs and fences and the location and dimensions of all open and/or <br />enclosed storage and trash receptacles. <br />Grading and Contours need to be shown. <br />SITE PLANS MIST BE COMPLETE AND LEGIBLE <br />Before applying, check your Site Plan to make sure that it contains all of the information <br />ailed above. You are encouraged to have one of our counter staff review your draft Site <br />Plan prior to having copies run. <br />Faint prints and light blue lines cannot be accepted because they cannot be reproduced <br />ar microfilmed <br />'ADEVSVQPlanning Application FOMMSite Plan Cheddistdoc (Revised OM3 -04) Page 1 of 1 <br />IN <br />