INIFIED PROGRAM CONSOLIDATED FOR TANK: TA0101401 <br />PR #: PR0231014 <br />FAC #: FA0003777 <br />UNDERGROUND STORAGE TANKS - TANK PAGE 2 <br />VI. PIPING CONSTRUCTION (Check all that apply) Page 3 of 3 <br />UNDERGROUND PIPING <br />ABOVEGROUND PIPING <br />SYSTEM TYPE ❑ I. PRESSURE ® 2. SUCTION ❑ 3. GRAVITY 458 <br />❑ 1. PRESSURE ❑ 2. SUCTION ❑ 3. GRAVITY 459 <br />CONSTRUCTION ❑ 1. SINGLE WALL 03. LINED TRENCH ❑ 99. OTHER 460 <br />❑ 1. SINGLE WALL ❑ 95. UNKNOWN 462 <br />%,02. DOUBLE WALL ❑95. OWN <br />❑ 2. DOUBLE WALL ❑ 99. OTHER <br />MANUFACTURER 461 <br />MANUFACTURER 463 <br />❑ L BARE STEEL ❑ 6. FRP COMPATIBLE w/ 100%METHANOL <br />❑ I. BARE STEEL ❑ 6. FRP COMPATIBLE w/ 10os/. METHANOL <br />❑ 2. STAINLESS STEEL ❑ 7. GALVANIZED STEEL <br />❑ 2. STAINLESS STEEL ❑ 7. GALVANIZED STEEL <br />❑ PLASTIC COMPATIBLE W/ CONTENTS ❑ 95. UNKNOWN <br />❑ PLASTIC COMPATIBLE W/ CONTENTS ❑ 95. UNKNOWN <br />® 4. FIBERGLASS ❑ 8. FLEXIBLE (HDPE) ❑ 99. OTHER <br />❑ 4• FIBERGLASS [18. FLEXIBLE (HDPE) ❑ 99. OTHER <br />❑ 5. STEEL W/COATING ❑ 9. CATHODIC PROTECTION 464 <br />❑ 5. STEEL W/COATING ❑ 9. CATHODIC PROTECTION 465 <br />VII. PIPING LEAK DETECTION (Check all that apply) (A description of the monitoring program shall be submitted to the local agency.) <br />UNDERGROUND PIPING ABOVEGROUND PIPING <br />SINGLE WALL PIPING 466 <br />SINGLE WALL PIPING 461 <br />PRESSURIZED PIPING (Check all that apply): <br />PRESSURIZED PIPING (Check all that apply): <br />❑ I. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF <br />❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF <br />FOR LEAK, SYSTEM FAILURE, AND SYSTEM DISCONNECTION+ AUDIBLE AND <br />FOR LEAK, SYSTEM FAILURE, AND SYSTEM DISCONNECTION+ AUDIBLE AND <br />VISUAL ALARMS. <br />VISUAL ALARMS. <br />❑ 2. MONTHLY 0.2 GPH TEST <br />❑ 2. MONTHLY 0.2 GPH TEST ❑ 3. ANNUAL INTEGRITY TEST (0.1 GPH) <br />❑ 3. ANNUAL INTEGRITY TEST (0.1 GPH) <br />❑ 4. DAILY VISUAL CHECK <br />CONVENTIONAL SUCTION SYSTEMS <br />CONVENTIONAL SUCTION SYSTEMS (Check all that apply) <br />❑ 5. DAILY VISUAL MONITORING OF PUMPING SYSTEM + TRIENNIEAL PIPING <br />❑ 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br />INTEGRITY TEST (0.1 GPH) <br />❑ 6. TRIENNIAL INTEGRITY TEST (0.1 GPH) <br />SAFE SUCTION SYSTEMS (NO VALUES IN BELOW GROUNDPIPING): <br />SAFE SUCTION SYSTEMS (NO VALUES IN BELOW GROUNDPIPING): <br />❑ 7. SELF MONITORING <br />❑ 7. SELF MONITORING <br />GRAVITY FLOW <br />❑ 9. BIENNIAL INTEGRITY TEST (0.1) GPH <br />GRAVITY FLOW (Check all that apply): <br />❑ 8. DAILY VISUAL MONITORING <br />❑ 9. BIENNIAL INTEGRITY TEST (0.1) GPH <br />SECONDARILY CONTAINED PIPING <br />SECONDARILY CONTAINED PIPING <br />PRESSURIZED PIPING (Check all that apply): <br />PRESSURIZED PIPING (Check all that apply): <br />10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br />10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br />ALARMS AND (Chock ate) <br />ALARMS AND (Check one) <br />❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br />a AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br />❑ b. AUTO PUMP SHUT OFF FOR LEAKS, SYSTEM FAILURE AND SYSTEM <br />b. AUTO PUMP SHUT OFF FOR LEAKS, SYSTEM FAILURE AND SYSTEM <br />DISCONNECTION <br />DISCONNECTION <br />❑ c. NO AUTO PUMP SHUT OFF <br />❑ c. NO AUTO PUMP SHUT OFF <br />❑ 11. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) WITH FLOW SHUT OFF OR <br />❑ 11. AUTOMATIC LEAK DETECTOR <br />RESTRICTION <br />❑ 12. ANNUAL INTEGRITY TEST (0.1 GPH) <br />❑ 12. ANNUAL INTEGRITY TEST (0.1 GPH) <br />SUCTION/GRAVITY SYSTEM <br />SUCTION/GRAVITY SYSTEM <br />;K13. CONTINUOUS SUMP SENSOR + AUDIBLE AND VISUAL ALARMS <br />❑ 13. CONTINUOUS SUMP SENSOR+ AUDIBLE AND VISUAL ALARMS <br />EMERGENCY GENERATORS ONLY (Check all that apply) <br />EMERGENCY GENERATORS ONLY (Check all that apply) <br />❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF • <br />❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF " <br />AUDIBLE AND VISUAL ALARMS <br />AUDIBLE AND VISUAL ALARMS <br />15. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) WITHOUT FLOW <br />❑ <br />❑ 15. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) WITHOUT FLOW <br />SHUT OFF OR RESTRICTION <br />SHUT OFF OR RESTRICTION <br />❑ 16. ANNUAL INTEGRITY TEST (0.1 GPH) <br />❑ 16. ANNUAL INTEGRITY TEST (0.1 GPH) <br />❑ 17. DAILY VISUAL CHECK <br />❑ 17. DAILY VISUAL CHECK <br />VIII. DISPENSER CONTAINMENT <br />DISPENSER CONTAINMENT ❑ I. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑ 4. DAILY VISUAL CHECK <br />DATE INSTALLED 468 ❑ 2. CONTINUOUS DISPENSER PAN SENSOR + AUDIBLE AND VISUAL ALARMS ❑ 5. TRENCH LINER / MONITORING <br />3. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR ❑ 6. NONE <br />)~DISPENSER+ AUDIBLE AND VISUAL ALARMS 469 <br />IX. OWNER/OPERATOR SIGNATURE <br />1 certify that the information provided herein is true and amaate to the bat of my knowledge. <br />SIGNATURE OF OWNER/OPERATOR <br />DATE 470 <br />NAME OF OWNER/OPERATOR (print) <br />TITLE OF OWNER(OPERATOR <br />471 <br />TRANSPORTATION MANAGER 477 <br />Pennit Number (For local use only) 473 Permit Approved (For local use only) 474 Permit Expiration Date (For local use only) a? S <br />PT0004753 EE0000817 12/31/2008 12:00:OOAM <br />UPCF (12/99 revised) <br />