My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2015 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FRESNO
>
1524
>
2300 - Underground Storage Tank Program
>
PR0506545
>
COMPLIANCE INFO_2015 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2023 10:44:17 AM
Creation date
9/24/2018 10:40:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015 - 2018
RECORD_ID
PR0506545
PE
2361
FACILITY_ID
FA0007491
FACILITY_NAME
VALLEY PACIFIC FRESNO AVE CARDLOCK
STREET_NUMBER
1524
STREET_NAME
FRESNO
STREET_TYPE
AVE
City
STOCKTON
Zip
95206
APN
16337025
CURRENT_STATUS
01
SITE_LOCATION
1524 FRESNO AVE
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
311
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.smgov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />VALLEY PACIFIC FRESNO AVE CARDLOCK <br />1524 FRESNO AVE, STOCKTON <br />March 12 2015 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />207 <br />CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The designated operator failed to check that the triennial secondary containment testing was completed within the <br />required time frame on the February 2015 designated operator monthly inspection report. The correct test date of <br />January 9, 2012 was noted, but the designated operator marked that testing was completed during the required time <br />frame. During the monthly inspection, the designated operator shall check that all required testing and maintenance <br />for the UST system have been completed and document the dates they were done. Ensure that designated operators <br />performing monthly inspections at this facility are including all of the required information on the reports. <br />This is a repeat violation, Class II. <br />314 <br />CCR 2631(a) Primary containment not tight (pre -Jul 2003). <br />The piping on the dispenser 1/2 piping was observed to be seeping, with a small amount of liquid pooled in the UDC, <br />indicating a leak in the primary piping. All primary containment for the UST system must be tight. Immediately have <br />a properly licensed, trained, and certified contractor repair or replace the failed component under permit and inspection <br />of the EHD. <br />This is a repeat violation, Class II. <br />321 <br />CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump. <br />The drain hole in the flex piping on the south diesel piping in the diesel STP sump was observed facing upward. Any <br />potential release from the primary containment into the secondary containment in the diesel piping does not flow into a <br />collection sump. All secondary containment systems shall be sloped so that all releases will flow to a collection <br />sump located at the low point of the underground piping. The drain was adjusted to the correct position at the time of <br />inspection. This was corrected on site. <br />This is a repeat violation, Class II. <br />2010 <br />CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to permit <br />conditions. <br />Piping replacement was done on the satellite #1 piping run on June 7, 2012 and tightness testing results have not <br />been submitted prior to operating the tank. Immediately provide copies of the test results to the EHD. <br />This is a repeat violation, Class II. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by April 11, 2015. <br />Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br />documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br />Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br />Received by <br />Inspector: r, <br />Phone: <br />Date: <br />(initial)* <br />STACY RIVERA, Senior REHS <br />(209) 468-3440 <br />03/12/2015 <br />Page 6 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.