Laserfiche WebLink
Hazardous Materials Program Guidance Document <br />HMPG-025 — Underground Storage Tank Overfill Prevention <br />A. Scope <br />This document addresses issues associated with underground storage tank (UST) overfill prevention <br />systems. For enforcement purposes, refer to the actual text of the regulations since the wording in this <br />document summarizes the requirements. References to Title 23 California Code of Regulations (23 CCR) use <br />citations in the updated regulations that are effective October 1, 2018. <br />B. General <br />The local agency may waive the requirement for overfill prevention equipment where the tank inlet exists <br />in an observable area, the spill container is adequate to collect any overfill, and the tank system is filled by <br />transfers of no more than 25 gallons at one time. [23 CCR §2635(c)(2)] [Note: This provision allows, but does not <br />require, the UPA to waive the requirement. In cases where the UST operator allows overfilling to occur, HMCD <br />may withdraw such a waiver and require the UST owner/operator to retrofit the UST with approved overfill <br />prevention equipment.] <br />All USTs that are not exempted pursuant to 23 CCR §2635(c)(2) must be equipped with an overfill prevention <br />system which does not allow for manual override and meets one of the following options: [23 CCR §2635(c)(1)] <br />Al Alert the transfer operator Flow restrictor (ball float) <br />when the tank is 907o full by installed below vent riser @ <br />restricting the flow into the tank 90% <br />[23 CCR §2635(c)(1)(A)] <br />A2 Or Alert the transfer operator External audible &visual <br />VY hen the tank is 90% full by alarm unit @ 90°° <br />triggering an audible and visual <br />alarm. [23 CCR §2635(c)(1)(A)] <br />g Restrict delivery of flow to the Flow restrictor (ball float) <br />tank at least 30 minutes before installed below vent riser @ <br />the tank overfills, provided the <_95% and external audible <br />restriction occurs when the alarm unit <br />tank is filled to no more than <br />95% of capacity; and activate an <br />audible alarm at least 5 minutes <br />before the tank overfills. <br />[23 CCR §2635(c)(1)(B)] <br />C Provide positive shut-off of flow Mechanical overfill prevention <br />to the tank when the tank is (flapper) valve @ 95% <br />filled to no more than 95% of <br />capacity. [23 CCR §2635(c)(1)(C)] <br />p Provide positive shut-off of flow <br />to the tank so that none of the <br />Mechanical overfill prevention <br />fittings located on the top of the <br />tank are exposed to product <br />due to overfilling. <br />[23 CCR §2635(c)(1)(D)] <br />AND <br />� <br />la er valve @ >95% '� <br />(f PP ) <br />I <br />i <br />HMPG-025 Page 1 of 7 1/7 —Rev. 09/20/18 <br />