My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012 - 2014
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FRESNO
>
1524
>
2300 - Underground Storage Tank Program
>
PR0506545
>
COMPLIANCE INFO_2012 - 2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/20/2019 11:18:53 AM
Creation date
9/24/2018 11:22:01 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO_2012 - 2014
FileName_PostFix
2012 - 2014
RECORD_ID
PR0506545
PE
2361
FACILITY_ID
FA0007491
FACILITY_NAME
VALLEY PACIFIC FRESNO AVE CARDLOCK
STREET_NUMBER
1524
STREET_NAME
FRESNO
STREET_TYPE
AVE
City
STOCKTON
Zip
95206
APN
16337025
CURRENT_STATUS
01
SITE_LOCATION
1524 FRESNO AVE
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
235
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
03/22/2012 06:17 0000000000 <br />File MH29467 Page Tl -2 of 2 Issued_ 2005-09-08 <br />S1MUL;MD USE RESISTANCE TO FLUIDS TEST (FIBERGLASS REINFORCED PLASTIC SUMP <br />MATERIALS); <br />METHOD <br />One sample assembly as described in Item a was placed in a container <br />filled with each of the flui-is Listed below such that the fittings l,nside the <br />container were completely covered with the fluids_ The samples and fluids <br />were maintained at a temperature of 100°F throughout the exposure. Following <br />30 days in this condition, the containers were subjected to an internal <br />pressure of 4.5 psig (based on a maximum sump depth of 10,3 ft.) for a period <br />of at least 5 min. while the samples were examined f -or evidence of leakage. <br />100% Methanol <br />505 Methanol/50* ASTM Reference Fuel C <br />15!k ttlsanol/851: ASTM Reference Fuel C <br />10% Ethanol,/90t ASTM Reference Fuel C <br />15% MTBE/85" ASTM Reference Fuel C <br />RESULTS <br />There was no evidence of leakage <br />SIMULATED USE RESISTANCE TO FLUIDS TEST Wl$ERGLASS REINFORCED PLASTIC SUMP <br />MATERIALS). <br />METHOD <br />one sample assembly as described in Stem C was placed in a container, <br />filled with each of the fluids Listed below such that the fittings .inside the <br />container were completely covered with the fluids. The samples and tl,tti,ds <br />were maintained at a temperature of 100°F throughout the exposure. Following <br />30 days in this condition, the containers were subjected to an internal <br />pres;rure of 4.5 prig (based on a maximum sump depth of 10.3 ft.) fox a period <br />of at least 5 m1n. while the samples were examined for evidence of leakage. <br />100 Methanol <br />501 Methanol/50* ASTM Reference Fuel. C <br />100% Ethanol <br />501 Ethanol/50% ASTM Reference Fuel C <br />15!4 gthanol/852 ASTM Reference Fuel C <br />10 Ethanol/901 ASTM Reference Fuel C <br />1.59t MTBE/851: ASTM Reference Fuel C <br />RESULTS <br />There was no evidence of .leakage <br />PAGE 24/30 <br />Dfversifled Products Manufacturing Inc. Approvals for Tech Manual Rev 2 Page 9 of 13 <br />
The URL can be used to link to this page
Your browser does not support the video tag.