My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
1400
>
2800 - Aboveground Petroleum Storage Program
>
PR0529108
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/21/2019 9:04:43 AM
Creation date
9/25/2018 4:10:22 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0529108
PE
2832
FACILITY_ID
FA0003704
FACILITY_NAME
DART CONTAINER CORP
STREET_NUMBER
1400
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04932015
CURRENT_STATUS
01
SITE_LOCATION
1400 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> ABOVEGROUND PETROLEUM STORAGE ACT (APSA) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Facility Dart Container Corp. Facility 1400 E. Victor Rd. Lodi, CA 95240 Inspection Dec 13, 2010 <br /> Name: p Address: Date: <br /> VIOLATIONS <br /> R HSC=CA Health and SafetyCode,CFR=Code of Federal Regulations;V=Violation;RV=Repeat violation <br /> # V v Code Section Speck requirements of HSC 25270.4.5 a are identified as CFR code sections lzeqinninq with 112 <br /> Failed to:test each aboveground container for integrity on a regular schedule or when repairs were made,- <br /> 48 <br /> ade;48 CFR 112.8(c)(6) inspect containers and container supports;or keep records of inspections and tests,or provide <br /> equivalence as allowed by CFR 112.7(a)(2) <br /> 49 CFR 112.8(c)(7) Failed to provide effective leakage control through defective internal heating coils,or provide equivalence <br /> as allowed by CFR 11 2.7(a)2 <br /> 50 CFR 112.8(c)(8) Failed to install and regularly test approved liquid level sensing devices,or provide equivalence as allowed <br /> by CFR 112.7a)2 <br /> 51 CFR 112.8(c)(9) Failed to observe effluent treatment facility frequently enough to detect system upsets that could cause a <br /> discharge,or provide equivalence as allowed by CFR 112.7(a)(2) <br /> 52 CFR 112.8(c)(10) Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas,or provide <br /> equivalence as allowed by CFR 112.7(a)(2) <br /> 53 CFR 112.8(c)(11) Failed to locate portable containers to prevent discharge or provide sufficient secondary containment <br /> capacity that will hold the volume of the largest container plus sufficient freeboard to contain precipitation <br /> Failed to provide buried piping with a protective wrapping and coating and cathodic protection and/or <br /> 54 CFR 112.8(d)(1) inspect buried piping for corrosion damage when exposed,or provide equivalence as allowed by CFR <br /> 112.7(a)(2) <br /> 55 CFR 112.8(d)(2) Failed to cap or blank-flange terminal connection at transfer point and mark its origin when piping is not in <br /> service or in standby service for an extended time,or provide equivalence as allowed by CFR 112.7(a)(2) <br /> 56 CFR 112.8(d)(3) Failed to design pipe supports to minimize abrasion and corrosion and to allow for expansion and <br /> contraction,or provide equivalence as allowed by CFR 112.7(a)(2) <br /> 57 CFR 112.8(d)(4) Failed to regularly inspect aboveground valves,piping,and appurtenances,or provide equivalence as <br /> allowed by CFR 112.7(a)(2) <br /> 58 CFR 112.8(d)(4) Failed to conduct integrity and leak test for buried piping at time of installation,modification,construction, <br /> relocation,or replacement,or provide equivalence as allowed by CFR 112.7(a)(2) <br /> 59 CFR 112.8(d)(5) Failed to provide adequate warnings to vehicles entering facility to protect aboveground piping and other <br /> oil transfer operations,or provide equivalence as allowed by CFR 112.7(a)(2) <br /> 999 Other: See attached"Continuation-Official Inspection Report"for violation(s)not listed above. <br /> On site to conduct a routine inspection. <br /> #6 The SPCC plan is not certified by a P.E. Facilities with greater than 10,000 gallons of above ground <br /> storage capacity for petroleum products must have a P.E. review and certify the facility SPCC Plan. <br /> Correct immediately by having a P.E. review and certify the facility SPCC Plan. <br /> #18 The facility SPCC Plan lacked the facility diagram. Describe in your SPCC Plan the physical layout of <br /> the facility and include a facility diagram, which must mark the location and contents of each fixed oil <br /> storage container and the storage area where mobile or portable containers are located. The facility <br /> diagram must also include all transfer stations and connecting pipes, including intra-facility gathering <br /> lines. Correct immediately by incorporating the required facility diagram into the facility SPCC Plan. <br /> #19 The SPCC Plan failed to include description of product type and storage capacity for each container. <br /> The facility SPCC Plan must include the description of the product type of oil in each fixed container and <br /> its storage capacity. For mobile or portable containers, either provide the type of oil and storage capacity <br /> for each container or provide an estimate of the potential number of mobile or portable containers, the <br /> types of oil. and anticipated storage capacities. Correct immediately by incorporating the required <br /> description of product type and storage capacity for each container into the facility SPCC Plan. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY <br /> RATE.THIS FACILITY IS SUBJECT TO REINSPECTION AT Y TIME AT EHD'S CURRENT HOURLY RATE. <br /> Inspector Phone: Received B Title 'n <br /> (/7✓ (209) 468-3453 /���}.r-�/l�/ir••��.c--• <br /> EHD 28-02 Rev 2/19/10 Page 3 APSA INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.