My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1998 -2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FRESNO
>
1524
>
2300 - Underground Storage Tank Program
>
PR0506545
>
COMPLIANCE INFO_1998 -2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2023 9:38:21 AM
Creation date
9/28/2018 11:22:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO_1998 -2011
FileName_PostFix
1998 -2011
RECORD_ID
PR0506545
PE
2361
FACILITY_ID
FA0007491
FACILITY_NAME
VALLEY PACIFIC FRESNO AVE CARDLOCK
STREET_NUMBER
1524
STREET_NAME
FRESNO
STREET_TYPE
AVE
City
STOCKTON
Zip
95206
APN
16337025
CURRENT_STATUS
01
SITE_LOCATION
1524 FRESNO AVE
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
269
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONi.. ORING SYSTEM CERT1 4;ATION <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited.- Chapter 6.7, Health and Safety Code, Chapter 16, Division 3, Title 23, California Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be <br />prepared for each monitoring system control panel by the technician who performs the work A copy of this form must be provided <br />to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems <br />within 30 days of test date. <br />A. General Information <br />Facility Name: <br />Site Address: <br />COUNTRY MARKET <br />1524 FRESNO AVE. <br />STOCKTON , CA 95206 <br />Bldg. No.: <br />Zip: <br />Facility Contact Person: Contact Phone No.: <br />Make/Model of Monitoring System: ;e'p /,.PYA? _ Date of Testing/Servicing:/ / O� <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate speciit5c equipment inspected/serviced: <br />Tank ID:v/&-52-- <br />1,Tank <br />ID: <br />V -hi -Tank Gauging Probe. Model: <br />❑ In -Tank Gauging Probe. <br />Model: <br />Annular Space or Vault Sensor. Model: <br />❑ Annular Space or Vault Sensor. <br />Model: <br />wiping Sump / Trench Sensor(s). Model: <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />,Wc'Mechanical Line Leak Detector. Model: c l <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />Tank Overfill / High -Level Sensor. Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other specify e ui ment t e and model in Section E on Page 2). <br />❑ Other (!2ecify equipment type and <br />model in Section E on Page 2).. <br />Tank ID: <br />Tank ID: <br />❑ In -Tank Gauging Probe. <br />Model: <br />❑ In -Tank Gauging Probe. Model: <br />❑ Annular Space or Vault Sensor. Model: <br />❑ Annular Space or Vault Sensor. <br />Model: <br />❑ Piping Sump / Trench Sensor(s). Model: <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. Model: <br />1 ❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. Model: <br />❑Tank Overfill / High -Level Sensor. <br />Model: <br />LJ Other (specify equipment e and model in Section E on Page 2). <br />❑ Other (s ecif equipment t e and <br />model in Section E on Pa c 2 . <br />penser ID: — <br />Dispenser ID: <br />Af <br />ispenser Containment Sensor(s). Model: 9—p <br />Dispenser Containment Sensor(s). <br />91 <br />Model: <br />hear Valve(s). <br />ED <br />Shear Valve(s). <br />is enserr Containment Floats and Chain(s). <br />❑Dis enser Containment Floats and <br />Chnias . <br />Dispenser ID: <br />Dispenser ID: <br />Dispenser Containment Sensor(s). Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />Shear Valve(s). <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Floats and Chain(s). <br />❑ Dispenser Containment Floats and Chain(s). <br />Dispenser ID: !2X::3Dispenser <br />ID: <br />Dispenser Containment Sensor(s). Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />Shear Valve(s). <br />❑ Shear Valve(s). <br />❑Dis enser Containment Floats and Chain(s). <br />❑ Dispenser Containment Floats and Chain(s), <br />u the tacnay contains more tanks or dispensers, copy tlus form. Include information for every tank and dispenser at the facility. <br />C. Cern' ication - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br />manuf cturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this <br />inform tion is correct and a Plot Plan showing the layout of monitoring equi ment. F r anyuipment capable of generating such �& a <br />report , I have also attachA a copy of the report; (check all that apply): st et- /rm history report <br />Technician Name (print): E I r'Ae:lf CPSignature: <br />�... <br />Certification No,; License, No.; <br />Testing Company Name: TANK-TEK ENVIRONMENTAL CORPORATION <br />Site Address, IS L A F9—SfNQ 1 'FG0z f <br />Phone No.: (707) 446-6151 <br />Date of Testing/Servicing: <br />Page 1 of 3 03/01 <br />Monitoring System Certification <br />
The URL can be used to link to this page
Your browser does not support the video tag.