My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1998 -2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FRESNO
>
1524
>
2300 - Underground Storage Tank Program
>
PR0506545
>
COMPLIANCE INFO_1998 -2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2023 9:38:21 AM
Creation date
9/28/2018 11:22:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO_1998 -2011
FileName_PostFix
1998 -2011
RECORD_ID
PR0506545
PE
2361
FACILITY_ID
FA0007491
FACILITY_NAME
VALLEY PACIFIC FRESNO AVE CARDLOCK
STREET_NUMBER
1524
STREET_NAME
FRESNO
STREET_TYPE
AVE
City
STOCKTON
Zip
95206
APN
16337025
CURRENT_STATUS
01
SITE_LOCATION
1524 FRESNO AVE
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
269
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone: (209)468-3420 Fax: (209) 468-3433 Web:www.sigov.org/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Facility address: Inspectlon Dab: <br /> 1524 FRESNO AVE, STOCKTON Jul 6, 2010 <br /> Code Section HSC=CA Health &SafetyCode; CCR=CA`C4 <br /> Code VIOLATIONS <br /> Regulations; V=Violation; RV=Re eat Violation V V <br /> Designated operator monthly inspection: (c)(1)alarms not documented; (c)(2-4)spill containers, <br /> 23c CCR 2715(c), (d), UDCs, and sumps(if necessary)not inspected; (c)(5)required test dates not checked or noted; (c)(6) <br /> (e) employee training not verified; (d)(e)monthly inspection reports not maintained on site for at least 12 <br /> months <br /> 23d CCR 2715(f) Designated operator employee training: (1) not performed, (2)not current for at least one employee <br /> on site; 3)log not kept <br /> Monitoring equipment certification: (a)not performed annually; (d)test report not submitted within 30 <br /> 24 CCR 2638 days; (e)test notification not provided to the EHD at least 48 hours prior to conducting an installation, <br /> repair, replacement, calibration, or certification, (f)performed, and failed to affix a tag/sticker on each <br /> monitoring equipment component that was certified, repaired, or replaced <br /> 25 HSC 25291(f) Annual line leak detector test not performed (AN) <br /> 26 HSC 25284.2 Annual spill containment testing not performed <br /> 27 CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present two) <br /> 28 CCR 2661(f) Repair for tank or piping not tested for tightness within 30 days of completion of the repair tM2► <br /> 29 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1, 1984) (M1) <br /> 30 CCR 2643(d) Triennial line test for conventional suction piping not performed (pre-January 1, 1984) (M�) <br /> 31 HSC 25292.5 ELD testing not performed on a system located within 1000'of public well, or failures not repaired and <br /> retested <br /> 32 CCR 2661 Permit to repair UST system not obtained <br /> 33 HSC 25286(a) Permit to alter monitoring system not obtained <br /> 34 HSC 25298(b) Permit to temporarily close UST system not obtained <br /> 35 HSC 25298(c) Permit to close UST system not obtained <br /> 36 HSC 25299(a)(9) Tamperinq with or disabling leak detection devices or alarms <br /> 37 HSC 25298(a) Illegally abandoned UST system <br /> 38 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least monthly or log not kept <br /> 39 CCR 2631.1(a) UST system is not compatible with the substance stored <br /> Emergency enerator systems <br /> 40 CCR 2636 6) Emergency enerator monitoring system not checked daily or log not kept (M�) <br /> 41 HSC 25281.5(b)(3) Unburied fuel piping not visually inspected at least monthly or log not kept (Mt) <br /> PR <br /> VPH Systems HSC 25290.2 installed between 07/01/03 and 06/30/04 HSC 25290.1 installed on or after 07/01/04 <br /> Compatibility and permeability requirements: (a)UST system is not compatible with the substance <br /> 42 CCR 2631.1 stored, (b)results of the compatibility and permeability testing requirements listed in subsections CCR <br /> 2631(b)and(d)for a UST system installed after July 1, 2004,were not submitted <br /> 43 HSC 25290.1(c)(1)HSC 25290.2(c)(1 Primary containment not liquid or vapor tight <br /> 44 HSC 25290.1(c)(2) Secondary containment not liquid or vapor tight <br /> HSC 25290.2(c)(2) <br /> 45 HSC 25290.1(c)(3) Secondary containment not constructed to prevent water intrusion <br /> HSC 25290.2(c)(3) <br /> 46 HSC 25290.1(d) Monitoring system not maintained to detect water intrusion into the secondary containment, or the <br /> HSC 25290.2(d) entry of liquid or vapor from the primary containment into the secondary containment <br /> 47 HSC 25290.1(e) Interstitial liquid measurement method, constant vacuum, or constant pressure in the interstitial space <br /> of the UST system not maintained <br /> HSC 25290.1(j) UST system not tested by one of the following methods prior to use: (1) Enhanced leak detection, (2) <br /> 48 HSC 25290.2(1) inert gas pressure test approved by SWRCB; (3)test method deemed equivalent to(1)or(2)by the <br /> SWRCB <br /> Other violations <br /> 999 Other: See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> /DinActor Phone. VIC <br /> �- (209) 468-9848 Septic system: <br /> ❑Serves>_20 people/day <br /> Rec e Title ^ <br /> [3 Receives other than sanitary waste <br /> Other disposal methods: <br /> ❑Dry wells/French Drains <br /> _HD 2 02- 2 REV 04/08/10 Page 2 UST OFFICIAL INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.